供貨周期 | 現貨 | 規格 | 12V38AH |
---|---|---|---|
貨號 | 198 | 主要用途 | UPS電源,直流屏 |
SHIMASTU蓄電池NP38-12 12V38AH電動工具
參考價 | 面議 |
更新時間:2020-11-02 15:02:07瀏覽次數:378
聯系我們時請說明是化工儀器網上看到的信息,謝謝!
SHIMASTU蓄電池NP38-12 12V38AH電動工具
SHIMASTU蓄電池NP38-12 12V38AH電動工具
Shimastu電子科技有限公司,一個的密封鉛酸(SLA)電池的廠家,引進日本AGM公司的技術基礎。Shimastu一直在研究、開發、生產和營銷SLA電池自2001年以來。采用*的技術過程從日本技術和現代化的生產設備和檢測設備,Shimastu一直為客戶提供SLA的NP系列電池使用壽命長,質量可靠,性能穩定。
Shimastu Electronic Technology Co., Ltd., a dedicated professional manufacturer of Sealed Lead Acid ( SLA) batteries, introducing Japan AGM technology from the company foundation. Shimastu has been researching, developing, manufacturing and marketing SLA batteries since 2001. Adopting the advanced technical process from Japan Technology and modern production machines and testing equipment, Shimastu has been supplying customers with NP series of SLA batteries which has long service life, good quality, reliable and stable performance.
Shimastu has more than 350 people including 30 technicians, located in the Pearl River Delta of Guangdong Province, China. Shimastu has been exporting SLA batteries to the world under its own brand "Shimastu" or by OEM orders. Shimastu can produce more than 150,000 units of batteries every month on average and take more than 30 quality control checks from IQC to FQC. Up to now, Shimastu has been awarded ISO14000, UL and CE certificates.
Warmly welcome to contact us for inquires, thanks
Shimastu包括30技術人員超過350人,位于廣東省珠江三角洲,中國。Shimastu已經向世界輸出SLA電池在其自己的品牌“Shimastu”或OEM訂單。Shimastu每個月可以生產150000臺以上的電池,平均30多從IQC對FQC質量控制檢查。到目前為止,Shimastu獲得ISO14000,UL和CE證書。
蓄電池應用領域與分類:
◆ 免維護無須補液; ● UPS不間斷電源;
◆ 內阻小,大電流放電性能好; ● 消防備用電源;
◆ 適應溫度廣; ● 安全防護報警系統;
◆ 自放電小; ● 應急照明系統;
◆ 使用壽命長; ● 電力,郵電通信系統;
◆ 荷電出廠,使用方便; ● 電子儀器儀表;
◆ 安全防爆; ● 電動工具,電動玩具;
◆ *配方,深放電恢復性能好; ● 便攜式電子設備;
◆ 無游離電解液,側倒仍能使用; ● 攝影器材;
◆ 產品通過CE,ROHS認證,所有電池 ● 太陽能、風能發電系統;
符合國家標準。 ● 巡邏自行車、紅綠警示燈等。
數據中心基礎設施管理顯示的內容令人困擾,而且圖形用戶界面并沒有任何意義,用戶登陸后的首菜單后,沒有看到問題。一大串數據顯示溫度已經持續升高了數小時。為什么我沒有更早得到告警?我發現一張看起來像天書的電氣圖,但我知道這個可能是UPS系統。我知道從那里可以找到我們服務器機柜的面板,但并不知道具體的控制機制。墻上還有一些電器面板,但標簽沒有任何意義。“LBTA-3”可能是任何東西,而且面板門被鎖住了。
設施與IT不匹配,數據中心就崩潰了——特別是在緊急情況下。解決沖突的一種方案是讓某個IT團隊成員也對設施管理負責。另一種方法是簡化兩部門之間的溝通。
設施工作人員趕到現場后,他證實了我已知道的事實:沒有足夠能源來支持我們所有設備。他檢查了所能找到的斷路器,沒有發現任何錯誤,但在沒有電工的情況下我們無法進一步排查。這時候只好繼續打電話給設施經理,接著等電工到達。
一臺接一臺,我關閉了服務器,避免災難性崩潰發生。不久電工到了,而且他知道電路板在哪里——那扇我們無法進入,只有靠他的特殊鑰匙才能打開的門后面。他開啟了大門,里面很涼快。這間同樣是UPS室,而里面只有一臺空調在運轉。單臺空調意味著我們的冗余UPS被安置在非冗余冷卻環境中。
事情升溫
在電工重置了跳閘的主斷路器后,空調開始恢復運作——但好景不長。火苗從電箱面板的小裂縫處冒出。我們的吸氣式煙霧探測系統如果及時通知我們事情嚴重了,我們就能在主消防系統釋放滅火氣體之前解決問題。煙霧迅速彌漫整個數據中心,伴隨著震耳欲聾的告警聲。但在沒有任何預警的情況下,主系統已經開始氣體釋放。由于數據中心內沒有著火,我按下了重載按鈕,但只有被重置了。消防員出現在門口。只有空調電源出現問題,不是UPS或服務器電源,但他們立刻到達了大紅色的EPO(緊急電源關閉)按鈕處。我朝他們大喊,但他們還是按下去了。幾秒鐘后,滅火氣體釋放了。電工趕往地下室切斷機房的主供電,而消防員正在往燃燒的配電箱中澆灌泡沫。
在DR站點遭到冷遇
當外海辦事處同事通過越洋電話詢問我發生了何事,為什么他們無法訪問時,我向他們保證,根據我們的災難恢復策略,需求會被轉發到災難恢復站點。然而,雖然我們已經簽約了站點,但我們實際并沒有進行任何傳輸操作,就是我們還沒有轉移IT基礎設施——無論是物理的還是虛擬的——到DR站點。當我打電話給DR供應商宣布緊急狀況時,他們告訴我站點沒有熱維護,也無法隨時上線。我們一直都在做日常數據備份到災難恢復中心,但需要時間讓我們進行用戶轉移操作。而且我們需要自己的員工到場才能進行。
There is only part technical specification on our website,聽 |
Model | Nominal Voltage | Nominal Capacity | Dimensions | Ht.Over Terminal | Weight Approx(kg) | Terminals | Accessories | |||||||
L | W | H | ||||||||||||
in | mm | in | mm | in | mm | in | mm | kg | lb | |||||
NPH8-12 | 12 | 8.5 | 5.94 | 151 | 2.56 | 65 | 3.74 | 95 | 4.25 | 108 | 2.75 | 6.06 | Q01 |
|
NPH9-12 | 12 | 10 | 7.17 | 182 | 2.56 | 65 | 3.74 | 95 | 4.25 | 108 | 6.94 | Q01 |
| |
NPH12-12 | 12 | 14 | 5.94 | 151 | 3.86 | 98 | 3.74 | 95 | 3.94 | 100 | 3.95 | 8.71 | T01(T02) |
|
NPH17-12 | 12 | 20 | 7.13 | 181 | 2.99 | 76 | 6.61 | 168 | 6.61 | 168 | 6.1 | 13.44 | Q02(B02) |
|
NPH18-12 | 12 | 18 | 7.13 | 181 | 2.99 | 76 | 6.61 | 168 | 6.61 | 181 | 5.6 | 12.3 | Q07 |
|
NPH24-12 | 12 | 27 | 6.89 | 175 | 6.5 | 165 | 4.96 | 126 | 4.96 | 126 | 8.9 | 19.62 | Q04(B03) |
|
NPH33-12 | 12 | 35 | 7.72 | 196 | 5.16 | 131 | 6.42 | 163 | 7.05 | 179 | 11.2 | 24.68 | Q19(B04) |
|
NPH40-12 | 12 | 42 | 7.8 | 198 | 6.54 | 166 | 6.77 | 172 | 6.77 | 172 | 14.2 | 31.31 | Q07(B04) |
|
NPH55-12 | 12 | 60 | 9.02 | 229 | 5.43 | 138 | 8.19 | 208 | 8.94 | 0 | 18 | 39.67 | Q08(B04) |
|
NPH65-12 | 12 | 70 | 13.78 | 350 | 6.16 | 168 | 7.01 | 178 | 7.01 | 178 | 22.5 | 49.59 | Q10(B04) |
|
NPH70-12 | 12 | 70 | 10.2 | 259 | 6.65 | 169 | 8.19 | 208 | 8.94 | 227 | 22.5 | 49.5 | B04 |
|
| ||||||||||||||
NPH75-12 | 12 | 85 | 10.2 | 259 | 6.65 | 169 | 8.19 | 208 | 8.94 | 0 | 25.2 | 55.54 | Q11(B04) |
|
NPH90-12 | 12 | 100 | 12.09 | 307 | 6.65 | 169 | 8.19 | 208 | 8.94 | 227 | 28.2 | 62.15 | Q13 |
|
NPH100-12 | 12 | 110 | 12.91 | 328 | 6.77 | 172 | 8.43 | 214 | 9.32 | 233 | 31.5 | 69.43 | Q14(B04) |
|
NPH120-12 | 12 | 120 | 16.02 | 407 | 6.85 | 174 | 8.23 | 209 | 9.37 | 238 | 36.9 | 81.33 | B04 |
|
NPH134-12 | 12 | 155 | 13.43 | 341 | 6.81 | 173 | 11.14 | 283 | 11.34 | 288 | 45 | 99.18 | B01 |
|
NPH150-12 | 12 | 166 | 13.43 | 341 | 6.81 | 173 | 11.14 | 283 | 11.34 | 288 | 46.5 | 102.49 | Q16(B05) |
|
NPH180-12 | 12 | 180 | 20.9 | 530 | 8.23 | 209 | 8.43 | 214 | 9.6 | 244 | 51 | 112.3 | Q17 |
|
鄭重聲明:本公司所售全部蓄電池保證是原廠原裝產品,,簽訂合同,并提供增值稅發票,38AH以上出現非人為質量問題三年內免費更換同等型號的全新電池,請廣大客戶放心采購!
本公司還供應以下產品:
湯淺蓄電池、松下蓄電池、理士蓄電池、賽特蓄電池、圣陽蓄電池、雙登蓄電池、非凡蓄電池、科士達蓄電池、梅蘭日蘭蓄電池、三瑞蓄電池、大力神蓄電池、凱鷹蓄電池、南都蓄電池、光宇蓄電池、風帆蓄電池、臥龍燈塔蓄電池、德國陽光蓄電池、美國山特電源、APCUPS不間斷電源
的ups不間斷電源鉛酸免維護蓄電池供應商及服務商
質量是企業的生命,服務是企業的根本。
全國代理經銷商 供應安徽 | 北京 | 福建 | 甘肅 | 廣東 | 廣西 | 貴州 | 海南 | 河北 | 河南 | 黑龍江 | 湖北 | 湖南 | 吉林 | 江蘇 | 江西 | 遼寧 | 內蒙古 | 寧夏 | 青海 | 山東 | 山西 | 陜西 | 上海 | 四川 | 天津 | 西藏 | 新疆 | 云南 | 浙江 | 重慶 | 香港 | 澳門 | 中國臺灣 |
----------------------------------------------------------------------------------------------
蓄電池是UPS系統中的一個重要組成部分,而用于控制蓄電池組輸出的保護開關,在實際應用中具有非常關鍵的作用,不僅承擔著蓄電池的正常切除和接通,而且在蓄電池出現過放、過載、短路等故障時,還應具有相應的保護功能。
艾默生網絡能源指出,在對電池開關進行選擇設計時,應考慮額定電壓、工作電流、短路電流等參數,但電池使用電壓范圍較寬,且現場電池連接線纜(或銅排)內阻及接觸電阻難以衡量,使得蓄電池系統短路電流無法精確計算,電池保護開關的設計和整定等方面缺少相應的依據,而如果蓄電池保護開關選擇不合理,在系統出現短路故障時無法及時脫扣,電池能量就會持續注入故障點,造成故障擴大化。
目前電池保護開關的設計,是基于電池的初始狀態進行計算和選擇的,而實際上蓄電池電壓和內阻是隨時間動態變化的。根據經驗,當電池老化時,內阻可能增加60%甚至更高,而一般電池的放電終止電壓是浮充電壓的70%左右。綜合考慮,當電池老化且電池電壓較低時,短路電流可能只有原來的40%左右。因此,當電池使用一段時間后,其電池短路電流會減小,發生短路時,電池保護開關很可能無法脫扣保護,從而使故障擴大化。另外,設計時往往考慮的是理想的短路狀態,而實際上電池短路可能是復雜多變的,短路點的阻抗是不可忽略而且難以準確衡量。這也是為什么即使嚴格按經驗和要求進行了電池保護開關配置,而實際上在很多事故中電池保護開關無法脫扣的關鍵原因。
同時在工程現場往往不能根據電池老化情況動態調整開關設置,針對這種情況,選擇具有主動脫扣功能的電池保護開關就顯得十分必要,可以很大地提高UPS供電系統的安全性。
基于顯著的應用效果,業內主流的UPS廠商,在產品設計上都普遍使用了具有主動脫扣功能電池保護開關。比如,艾默生網絡能源為大容量UPS產品提供電池保護開關(BCB)盒選件,其硬件包括電池保護開關控制板、帶脫扣裝置的電池保護開關、電池保護開關控制板到UPS之間的控制線纜、電池溫度傳感器(選件)等。