供貨周期 | 現貨 | 規格 | 12V33AH |
---|---|---|---|
貨號 | 198 | 主要用途 | UPS電源,直流屏 |
SHIMASTU蓄電池NP33-12 12V33AH航海設備
參考價 | 面議 |
更新時間:2020-11-02 15:02:07瀏覽次數:285
聯系我們時請說明是化工儀器網上看到的信息,謝謝!
SHIMASTU蓄電池NP33-12 12V33AH航海設備
SHIMASTU蓄電池NP33-12 12V33AH航海設備
我司代理蓄電池產品,;如需詳細了解更多蓄電池技術參數及規格,請通過以上的聯系我;我們公司還設有經驗豐富的工程師團隊;對一些疑難解答和方案設計都有著多年的經驗。我們將熱誠為你服務!!!
-------------------------------------------------------------------------------
The paralleled cells of SHIMASTU battery can be installed on the wood or steel stacks, but it is better to install on the special stacks.
There is no technical reason for limiting the number of strings but for practical installation reasons. It is recommended not allowed to exceed 3 strings in parallel especially if the battery is used in high discharge rates(backup time less than 15 mins)
但出于實際安裝的原因。建議不允許并行超過3串,特別是在高放電率(備份時間小于15分鐘)的情況下。
Shimastu電子科技有限公司,一個的密封鉛酸(SLA)電池的廠家,引進日本AGM公司的技術基礎。Shimastu一直在研究、開發、生產和營銷SLA電池自2001年以來。采用*的技術過程從日本技術和現代化的生產設備和檢測設備,Shimastu一直為客戶提供SLA的NP系列電池使用壽命長,質量可靠,性能穩定。
Shimastu包括30技術人員超過350人,位于廣東省珠江三角洲,中國。Shimastu已經向世界輸出SLA電池在其自己的品牌“Shimastu”或OEM訂單。Shimastu每個月可以生產150000臺以上的電池,平均30多從IQC對FQC質量控制檢查。到目前為止,Shimastu獲得ISO14000,UL和CE證書。
蓄電池應用領域與分類:
◆ 免維護無須補液; ● UPS不間斷電源;
◆ 內阻小,大電流放電性能好; ● 消防備用電源;
◆ 適應溫度廣; ● 安全防護報警系統;
◆ 自放電小; ● 應急照明系統;
◆ 使用壽命長; ● 電力,郵電通信系統;
◆ 荷電出廠,使用方便; ● 電子儀器儀表;
◆ 安全防爆; ● 電動工具,電動玩具;
◆ *配方,深放電恢復性能好; ● 便攜式電子設備;
◆ 無游離電解液,側倒仍能使用; ● 攝影器材;
◆ 產品通過CE,ROHS認證,所有電池 ● 太陽能、風能發電系統;
符合國家標準。 ● 巡邏自行車、紅綠警示燈等。
微模塊綜合布線系統——微模塊采用上走線的布線系統,在頂部安裝線槽,實現線纜的有序管理。具體特征包括:微模塊頂部實現強電線槽和弱電線槽分離,分別用于電源線和信號線走線;紅色標簽線槽走強電,藍色標簽線槽走弱電;微模塊頂部提供橫向線槽和縱向線槽;橫向線槽位于微模塊每列機柜頂部,實現橫向走線,縱向線槽連通微模塊兩列機柜;微模塊頂部線槽內有清晰的強弱電標識;每個機柜內后部左側安裝弱電線槽,右側安裝兩條豎裝的交流PDU和直流PDU;兩個微模塊之間通過機房走線架進行連接,走線架分為電源線走線架和信號線走線架。
微模塊智能管理系統——微模塊數據中心需要設置24小時不間斷運行的智能管理系統。系統對機房微模塊內的動力設備、環境設備、安防設備統一監控,并實現對微模塊能耗、資產、容量等統一運維管理,終達到對微模塊基礎設施智能化監控管理的要求。微模塊監控系統作為云管理服務系統中的一個組成部分,通過交換機,將每個微模塊的信息統一與上層的云管理服務系統進行互聯互通。
當機房僅有一個模塊時,微模塊內置的監控系統可以獨立完成該模塊的基礎設施監控能力,通過顯示層的各種展示終端和報警發送設備,實現微模塊監控與用戶的人機交互。在有多個微模塊組成的數據中心中,微模塊內置的數據采集處理單元將采集的數據和處理后的結果、報警信息等上傳至上級云管理服務系統。
面向未來 微模塊數據中心持續演進
當前,政企市場正在快步進入云計算時代,一方面越來越多的中小企業從自建小微數據中心轉而向成熟的云計算服務提供商購買云服務;另一方面,政府也開始嘗試與IT廠商合作建立市級、省級的云計算數據中心,為二級單位提供云服務,云計算已經從前幾年的概念炒作發展到在政企市場中實用的階段。
可以預見,數據中心作為支撐云計算服務的基礎單元,隨著云計算的快速發展,勢必會呈現集中化、大型化、化的趨勢,微模塊數據中心正是在這種背景下出現的一種新型數據中心部署形式。
云計算的重要特征之一就是彈性擴容,而實現數據中心的彈性化部署則是其中尤為重要的一環。IT界的新技術往往早出自更具創新力的互聯網企業,在建設彈性數據中心的探索中,由于對數據中心的需求量更大,規模更集中,又更加看重成本,國內外的大型互聯網企業又一次走在了行業的前列。以Google的比利時數據中心為例,配電和制冷分別位于機房兩側,采用類似集裝箱的模塊化單元,機房內部也采用了冷、熱通道隔離的微模塊單元,實現了真正的模塊化數據中心。但國外的成功經驗并不一定適用于我國,在土地資源尤其緊張的中國,容積率超低的單層廠房式數據中心無疑是的,所以更加適合多層數據中心的室內微模塊正在成為國內彈性數據中心探索的主要方向。
There is only part technical specification on our website,聽 |
Model | Nominal Voltage | Nominal Capacity | Dimensions | Ht.Over Terminal | Weight Approx(kg) | Terminals | Accessories | |||||||||||||||
L | W | H | ||||||||||||||||||||
in | mm | in | mm | in | mm | in | mm | kg | lb | |||||||||||||
FA55-12 | 12 | 55 | 10.91 | 277 | 4.17 | 106 | 8.74 | 222 | 8.74 | 222 | 18 | 39.67 | B04 | · download | ||||||||
FA75-12 | 12 | 75 | 22.12 | 562 | 4.48 | 114 | 7.4 | 188 | 7.4 | 188 | 29 | 63.92 | B04 | · download | ||||||||
FA100-12 | 12 | 100 | 15.51 | 394 | 4.29 | 109 | 11.22 | 285 | 11.22 | 285 | 35 | 77.14 | B04 | · download | ||||||||
FA105-12 | 12 | 105 | 19.69 | 507 | 4.29 | 109 | 9.37 |
| 37 | 238 | 36 | 79.34 | B04 | · download | ||||||||
FA120-12 | 12 | 120 | 21.69 | 551 | 4.29 | 109 | 9.41 | 239 | 9.41 | 239 | 37.5 | 82.65 | B04 | · download | ||||||||
FA150-12 | 12 | 150 | 21.69 | 551 | 4.29 | 109 | 11.3 | 287 | 11.3 | 287 | 47.5 | 104.69 | B04 | · download | ||||||||
FA180-12 | 12 | 180 | 22.05 | 560 | 4.92 | 125 | 12.44 | 316 | 12.44 | 316 | 57 | 125.63 | B04 | · downloa | ||||||||
| ||||||||||||||||||||||
PHYSICAL SPECIFICATION | ||||||||||||||||||||||
Nominal Voltage Nominal Capacity (10HR) | 12V 9Ah |
| ||||||||||||||||||||
Dimension | Length Width Container Height Total Height | 152±1mm (5.98 inches) 87±1mm (3.42 inches) 107±1mm (4.21 inches) 107±1mm (4.21 inches) | ||||||||||||||||||||
Weight | Approx. 3.1Kg (6.83lbs) | |||||||||||||||||||||
Standard Terminal | F1-Fasten Tab M01 | |||||||||||||||||||||
| ||||||||||||||||||||||
ELECTRICAL SPECIFICATION | ||||||||||||||||||||||
Characteristics | Discharge curves @ 25℃ (77 °F) | |||||||||||||||||||||
Capacity | 10 hour rate (0.9A) 5 hour rate (1.53A) 1hour rate (5.4A) | 9Ah 7.6Ah 5.4Ah |
| |||||||||||||||||||
Capacity affected by temperature | 40℃ (104 0F) 25℃ (77 0F) 0℃ (32 0F) | 102% 85% | ||||||||||||||||||||
Internal Resistance | Full charged battery (25℃,77 0F) 10mΩ | |||||||||||||||||||||
Discharge at 72A for 5 seconds (-10℃) | ≥9.3V | |||||||||||||||||||||
Discharge at 72A for 90seconds (-10℃) | ≥6V | |||||||||||||||||||||
Constant Voltage Charge | Cycle | Initial Charging Current less than 2.7A Voltage 14.4~15.0V at 25℃ (77 0F ) Temperature Coefficient –5mV/℃ | ||||||||||||||||||||
Standby | No limit on Initial Charging Current Voltage 13.5~13.8V at 25℃ (77 0F ) Temperature Coefficient –3.3mV/℃ |
供方責任:
38AH(含38AH)以上蓄電池,質保期為三年,三年出現任何非人為質量問題,免費更換全新的同品牌同型號規格的蓄電池.非人為質量問題包括:運輸過程中造成的電池破損、鼓包、漏液、電池電壓范圍異常、接線端子變形等.
本公司還供應以下產品:
湯淺蓄電池、松下蓄電池、理士蓄電池、賽特蓄電池、圣陽蓄電池、雙登蓄電池、非凡蓄電池、科士達蓄電池、梅蘭日蘭蓄電池、三瑞蓄電池、大力神蓄電池、凱鷹蓄電池、南都蓄電池、光宇蓄電池、風帆蓄電池、臥龍燈塔蓄電池、德國陽光蓄電池、美國山特電源、APCUPS不間斷電源
的ups不間斷電源鉛酸免維護蓄電池供應商及服務商
質量是企業的生命,服務是企業的根本。
全國代理經銷商 供應安徽 | 北京 | 福建 | 甘肅 | 廣東 | 廣西 | 貴州 | 海南 | 河北 | 河南 | 黑龍江 | 湖北 | 湖南 | 吉林 | 江蘇 | 江西 | 遼寧 | 內蒙古 | 寧夏 | 青海 | 山東 | 山西 | 陜西 | 上海 | 四川 | 天津 | 西藏 | 新疆 | 云南 | 浙江 | 重慶 | 香港 | 澳門 | 中國臺灣 |
----------------------------------------------------------------------------------------------
安全和可靠是數據中心供電系統的主要問題。供電系統指的是從市電變壓器、發電機組之后,包括ATS自動切換開關、配電系統、UPS、供電電纜等環節,他們之間的配置決定了整個供電系統的可靠性。我們都知道衡量數據中心的價值有三個性能指標:可用性、適應性、TCO。其中的可用性指標是首要的,而供電系統的可用性,包含了系統中設備的可靠性、可管理性和可維護性。我們在考慮數據中心供電系統的可用性的時候都需要注意哪些問題呢?
1、斷路器數量增加以及斷路器指標的離散性問題
每個斷路器都是一個單路徑故障點。另外,相同指標而不同廠商的斷路器,其運行過程的實際動作穩定值也存在著很大差異,在這很大程度上影響了數據中心電路保護機制。情況糟糕時,下游斷路器可能不會動作,而終導致上游斷路器動作,結果發生大面積負載掉電的情況。
2、操作人員人為操作失誤的問題
超過54%的宕機故障都是人為因素造成的。其中,大部分是由于目前數據中心復雜性*而又缺乏處理這類復雜系統的技術人員等原因造成的。除此之外,針對如此復雜的系統,對人員進行的培訓也遠遠沒有達到所需的水平。再加上這些行業內的人員的高流動率,我們就很容易理解"人為因素"是宕機或可用性降低的首要原因了。
3、如何把UPS與IT設備負載之間的故障點減少至少
許多負載宕機的故障發生在UPS與IT設備負載之間。過去,用戶通常在UPS以及發電機之間引入冗余設備,但是他們往往容易忽略終端配電一級的單路徑故障點,例如他們在UPS和IT設備負載之間設置多個斷路器,而且UPS和IT負載之間的距離很長。所以希望冗余設施距離負載能夠更近一些,減少UPS和IT設備之間的斷路器數量。
4、減少大面積斷電的故障點
集中式供電優點很多,但它的致命缺陷是一旦UPS系統發生故障,所有設備設備均會停電而宕機;分布式供電雖然解決了大面積業務中斷的問題,但是其不易管理。用戶們當然是希望消除并控制自己的電源系統的故障。
5、UPS對供電系統的諧波*問題
UPS在整個系統內部就相當于一個諧波*器。無功和諧波電流對供電系統的影響是多方面的,因此是我們不得不的問題之一。
6、用戶內部以及用戶與廠商之間的信息共享問題
由于各種設備安裝的復雜性,故障發生時對故障根源的分析變得非常困難。客戶們普遍希望能夠通過統一標準的系統收集數據和比較結果,并且規范校正和處理的措施。因此他們希望同一機構內不同場地的機房能夠使用同樣的設備,不同部門的管理人員能夠相互分享管理經驗及故障處理經驗,也希望設備供應商能夠提供這些技術知識。
數據中心對供電系統的要求越來越高,供電系統的可用性問題也是保障數據中心安全可靠所必須解決的問題之一。我們應當減少故障與失誤,能為數據中實現其可用性的價值。