供貨周期 | 現貨 | 規格 | 12V65AH |
---|---|---|---|
貨號 | 159 | 主要用途 | UPS電源 |
BB鉛酸蓄電池BP65-12 12V65AH儲能應用
參考價 | 面議 |
更新時間:2020-11-02 15:02:07瀏覽次數:429
聯系我們時請說明是化工儀器網上看到的信息,謝謝!
BB鉛酸蓄電池BP65-12 12V65AH儲能應用
BB鉛酸蓄電池BP65-12 12V65AH儲能應用
Zelus is a VRLA battery with a gelified electrolyte; the sulfuric acid is mixed with silica fume, which makes the resulting mass gel-like and immobile. GEL batteries virtually eliminate the electrolyte evaporation, spillage (and subsequent corrosion Issues) common to the wet-cell battery, and more features like greater resistance to extreme temperatures, shock, and vibration. The valve regulation system allows for gas to be expelled. They are the same as wet (non-sealed) batteries except that the antimony in the lead plates is replaced by calcium. This preserves the mechanical characteristics but renders the construction far less prone to gassing.
我們愿意與朋友們攜手共進,共同發展,創造的未來。
美美電池有限公司系臺商獨資企業, 92年10月注冊登記, 投資總額3000萬美元, 占地面積80畝, 建筑面積60000平方米. 96年正式投產, 當年出口產值400萬美元, 97年出口產值626萬美元, 98年出口產值1460萬美元。
公司全部采用國外進口之新生產設備及檢測儀器, 生產各種類型之密閉式免維護鉛酸蓄電池. 年產量達4200萬AH以上. 已先后通過美國UL檢驗, 德國VDS產品安全認證﹐土耳其TSE質量認可。
公司于1996年10月份獲得DNV的ISO 9002質量體系認證, 又在1998年12月獲得ISO 9001質量體系認證, 2001獲得ISO14000環境體系認證。產品歐美,東南亞等許多國家及地區。
產品用途
蓄電池應用領域與分類:
◆ 免維護無須補液; ● UPS不間斷電源;
◆ 內阻小,大電流放電性能好; ● 消防備用電源;
◆ 適應溫度廣; ● 安全防護報警系統;
◆ 自放電小; ● 應急照明系統;
◆ 使用壽命長; ● 電力,郵電通信系統;
◆ 荷電出廠,使用方便; ● 電子儀器儀表;
◆ 安全防爆; ● 電動工具,電動玩具;
◆ *配方,深放電恢復性能好; ● 便攜式電子設備;
◆ 無游離電解液,側倒仍能使用; ● 攝影器材;
◆ 產品通過CE,ROHS認證,所有電池 ● 太陽能、風能發電系統;
符合國家標準。 ● 巡邏自行車、紅綠警示燈等
作為一種全新的供電模式,高壓直流供電技術已經開始應用于數據中心IT設備供電。
在一直強調“綠色”發展的數據中心領域,能成為主供電系統的高壓直流沒有讓人失望。
勞倫斯伯克利國家實驗室五年的研究成果證明,數據中心使用高壓直流配電可能節約10%-20%的能源消耗。
首先高壓直流供電系統具備高可靠性,其主要從三個方面體現:一是采用直流供電,蓄電池可以作為電源直接并聯在負載端,當停電時,蓄電池的電能可以直接供給負載,確保供電的不間斷。二是直流供電只有電壓幅值一個參數,各個直流模塊之間不存在相位、相序、頻率需同步的問題,系統結構簡單很多,可靠性大大提高。三是交流UPS系統雖然可以提高冗余度來提高安全系數,但是由于涉及到同步問題,每個模塊之間必須相互通信來保持同步,所以還是存在并機板的單點故障問題。而直流模塊沒有這些問題,即使脫離控制模塊,只要保持輸出電壓穩定,也能并聯輸出電能。
其次高壓直流供電系統還具備高效節能特點。和交流UPS系統相比,直流供電省掉了逆變環節,而一般逆變的損耗在5%左右,因此電源的效率得以提高。并且,由于服務器輸入的是直流電,也就不存在功率因數及諧波的問題,降低了線損。后由于并機技術簡單,可以采用大量的模塊并聯,使每個模塊的使用率可達到70%~80%,比起交流UPS系統提高了很多。
后高壓直流供電系統還具備可維護、擴容便捷的特點,因為采用高壓直流供電,就如現在一直使用的48V直流系統一樣,系統由模塊組成,維護人員可以自己進行維護。
目前,高壓直流供電技術已經在國內多個運營商建設項目中得到了大量的應用,并憑借在實際應用中表現出的高可靠性、高節能效果以及運行成本大幅降低的優異特質,得到了各大運營商的高度肯定和大力支持。
高壓直流PDU*
作為高壓直流供電系統的重要組成部分——高壓直流PDU也在此扮演重要的角色。
通信電源模塊根據供電到通信設備電源輸入端的電源電壓的種類,可分為交流供電系統和直流供電系統。目前,電信網絡設備采用48V直流電源供電;數據通信設備采用380/220V交流UPS供電。
傳統的PDU就是給數據通信設備供電的交流380/220V電源分配單元。
而240V高壓直流PDU是給數據通信設備供電的直流240V電源分配單元,高壓是相對于48V低壓直流電源供電而言的,但其供電的對象卻不是電信網絡設備,而同樣是數據通信設備。
目前國內直流PDU還在起步階段,試運營的直流PDU主要來自非廠商。突破電氣通信用240V直流PDU是依據《YDT2378-2011通信用240V直流供電系統》標準設計,符合標準的要求,并通過了泰爾實驗室的檢測。同高壓直流供電系統相*,是高壓直流供電系統的重要組成部分,并延續突破PDU質量可靠、工藝成熟,安全性能高的產品特點;采取定制化服務,安全按照客戶的實際需求定制;鋁合金型材外殼,輸入輸出形式靈活;在安裝方面,具有橫安裝和豎安裝的產品,可大限度地滿足現場安裝調試的需要。
顏輝說:“目前,突破電氣高壓直流PDU在運營商數據中心供電領域,已經得到了認可。在呼和浩特電信IDC機房直流電源改造項目中,采用了突破電氣的高壓直流PDU產品,配合整體機房改進,電能節省約20-30%。其實突破電氣一直致力于通過節能設備的選用及維護,促進節能減排,推動機房的綠色環保理念。”
利用高壓直流對IT設備供電,改變了傳統的供電模式受到業界的高度關注,尤其是經濟效益和社會效益顯著,相信很快將會被通信運營商和IT行業接受和普及。
BB蓄電池型號參數表:
Model | Voltage | Nominal Capacity | Weight | Terminal | Dimension | Model | ||||||||||||
15 Min W/Cell | 10hr Ah | Kg | Lbs | Standard | Optional | L | W | H | TH | |||||||||
Type | Position | Type | Position | MM | INCH | MM | INCH | MM | INCH | MM | INCH | |||||||
HR9-6 | 6 | 36 | 8 | 1.40 | 3.09 | T2 | 2 | T1 |
| 151 | 5.94 | 34 | 1.34 | 94 | 3.70 | 100 | 3.94 | HR9-6 |
HR4-12 | 12 | 16 | 3.5 | 1.40 | 3.09 | T1 | 3 | T2 |
| 134 | 5.28 | 67 | 2.64 | 60 | 2.36 | 66 | 2.60 | HR4-12 |
HR5.5-12 | 12 | 22 | 5 | 1.80 | 3.97 | T1 | 3 | T2 |
| 90 | 3.54 | 70 | 2.76 | 102 | 4.02 | 106 | 4.17 | HR5.5-12 |
HR5.8-12 | 12 | 23 | 5.3 | 1.88 | 4.15 | T1 | 3 | T2 |
| 90 | 3.54 | 70 | 2.76 | 102 | 4.02 | 106 | 4.17 | HR5.8-12 |
HR6-12 | 12 | 24 | 5.5 | 2.10 | 4.63 | T1 | 5 | T2 |
| 151 | 5.94 | 51 | 2.01 | 94 | 3.70 | 100 | 3.94 | HR6-12 |
HR8-12 | 12 | 32 | 7 | 2.60 | 5.73 | T2 | 5 | T1 |
| 151 | 5.94 | 65 | 2.56 | 94 | 3.70 | 100 | 3.94 | HR8-12 |
HR9-12 | 12 | 36 | 8 | 2.75 | 6.06 | T2 | 5 | T1,B0 |
| 151 | 5.94 | 65 | 2.56 | 94 | 3.70 | 100 | 3.94 | HR9-12 |
HR15-12 | 12 | 60 | 13 | 4.20 | 9.26 | T2 | 5 | T1 |
| 151 | 5.94 | 98 | 3.86 | 94 | 3.70 | 98 | 3.86 | HR15-12 |
HR22-12 | 12 | 88 | 20 | 6.50 | 14.33 | B1 | 7 | T2,I1 | 6 | 181 | 7.13 | 76 | 2.99 | 166 | 6.54 | 166 | 6.54 | HR22-12 |
HR33-12 | 12 | 132 | 31 | 10.00 | 22.05 | B1 | 7 | T2,I1 | 9 | 175 | 6.89 | 166 | 6.54 | 125 | 4.92 | 125 | 4.92 | HR33-12 |
HR40-12S | 12 | 160 | 38 | 12.10 | 26.68 | B7 | 8 |
|
| 195 | 7.68 | 129 | 5.08 | 155 | 6.10 | 179 | 7.05 | HR40-12S |
HR40-12H | 12 | 160 | 38 | 12.10 | 26.68 | B7 | 8 | I2 |
| 210 | 8.27 | 129 | 5.08 | 168 | 6.61 | 179 | 7.05 | HR40-12H |
HR40-12F | 12 | 160 | 38 | 12.10 | 26.68 | B7 | 8 | I2 |
| 195 | 7.68 | 129 | 5.08 | 168 | 6.61 | 179 | 7.05 | HR40-12F |
HR50-12 | 12 | 200 | 48 | 15.30 | 33.74 | B2 | 7 | I1,I2 |
| 197 | 7.76 | 165 | 6.50 | 171 | 6.73 | 171 | 6.73 | HR50-12 |
HR75-12 | 12 | 300 | 73 | 24.75 | 54.57 | B5 | 15 | I2 |
| 350 | 13.78 | 166 | 6.54 | 174 | 6.85 | 174 | 6.85 | HR75-12 |
BB蓄電池作為APC電池
采用澳洲99.99%的純鉛原料,日本高密度隔離板和安全閥,確保。
精密工藝及全線多道的檢測,免除電解液及氣體漏出。
特殊電解質配方,延長使用壽命,比一般電池循環壽命提升50%。
任意位置,任意行事均可安裝使用,不受空間限制,方便安全。
特殊格子體排列設計,精密的鑄造技術,強化極板耐腐蝕性。
生產過程采用全自動化電腦生產線及C.C.D.S充放電檢測系統,保證了產品*性。
低阻抗設計,自放電性低,容量保持及存儲時間在20℃下可達18個月以上。
有別于IT設備過去的“煙囪式”擺放,這里服務器陣列整齊壯觀;有別于過去雜亂無章的布線系統,這里外部幾乎看不到明線;有別于成堆的空調系統,這里的制冷系統更善于利用自然資源;有別于運維人員忙忙碌碌的工作身影,這里的運營管理通過遠程操控完成。
不錯,這就是新一代數據中心,在燈光的照射下,有些夢幻的感覺。
正迎來新一輪數據中心建設熱潮,新一代數據中心要求建設者能夠提供“一攬子”解決方案,以*平衡“高效、簡單、綠色、智能、彈性”等特征。
在CT領域耕耘多年的華為在IT領域同樣擁有不俗的實力,其研發和CT幾乎是同步進行的。2010年宣布進軍IT領域,如今華為已經具備提供端到端云計算解決方案的能力;在能源領域,華為網絡能源解決方案,數年來不間斷地支撐1/3的通信服務,以實現“佳轉換效率、佳供電、佳能耗KPI”為目標,餞行“ICT領域能效管理專家”的愿景,幫助客戶以更低的CAPEX和OPEX保障ICT設施安全穩定和智能高效地運行。
把握時代脈搏,華為創新性地提出“簡單、柔性、智能、節能”4S理念,新一輪數據中心建設潮流。
端到端解決方案,為客戶創造大價值
華為,憑借主設備與能源雙重供應商身份的天然優勢,加上豐富的項目管理經驗和的服務提供能力,從客戶需求出發,為客戶提供4S數據中心端到端解決方案,使得華為迅速打開市場。
1、端到端解決方案,更加安全可靠。
新一代數據中心是通信網絡新的核心節點,對安全可靠的需求非常苛刻。華為成熟的產品和成功的數據中心解決方案可以降低客戶的實施和運行風險,確保業務安全穩定的上線和運行。華為有效的數據中心評估和遷移工具可以準確獲取現狀信息,提出合理的容量建議,優化數據中心設計,高效準確完成遷移工作。華為端到端的可選安全模塊便于客戶根據自己*的安全要求選擇不同的安全模塊。
2、端到端解決方案,較綠色節能。
數據顯示,2011年,我國數據中心總耗電量達700億千瓦時,已經占到全社會用電量的1.5%,相當于2011年天津市全年的總用電量。數據中心的高能耗,不僅給企業帶來了沉重的經濟負擔,也造成了全社會能源的巨大浪費。
為推動數據中心的節能減排,工業和信息化部在《工業節能“十二五”規劃》提出,到2015年,數據中心PUE值需下降8%的目標。國家發改委等組織的“云計算示范工程”也要求示范工程建設的數據中心PUE要達到1.5以下。PUE1.5同樣是《通信業“十二五”規劃》對新建大型云數據中心的要求。
華為提倡綠色節能模塊化的架構設計,輔以高效UPS、近端制冷、自然冷卻等技術,可以幫助客戶降低機房PUE(大型數據中心小于1.5),降低能耗,并根據需要逐步快速擴容,提高數據中心的生命周期。
3、端到端解決方案,幫助用戶構建智能的超寬帶數據中心。
自動化已經成為新一代數據中心的另一個重要特征。傳統的數據中心,一旦發生任何故障問題,需要運維人員親自前往解決問題,這往往需要耽誤很長的時間。顯然,在市場競爭日益激烈的,企業CEO和CIO是不希望看到這種情況出現的。他們希望能夠實現數據中心的智能化管理,省去繁瑣的人工操作流程。
全面
BB已經通過德國TUV機構ISO9001、ISO9002兩項質量認證認證及美國UL認證。產品全部經美國C.C.D.S電腦自動化系統輛次充放電檢驗。
環保先鋒
BB在美國有15000個電池回收站,并通過德國TUV機構ISO14001環保認證。成為同時通過ISO9001及ISO14001認證的電池廠商
服務的理念
BB客戶遍及40多個國家和地區。主要客戶有:APC、EXIDE、DELTEC、DELTA、SIEMENS、ERICSSON、PCM、MGR、BEST、LIEBERT等。
BB蓄電池電槽外殼經超音波特殊密封,置放時不受方向、位置之限制,除依印刷字體方向置放外,亦可以倒立放置、橫向放置等各種放置方式,均不影響其安全與功能。 以特殊配方的鉛鈣合金及全自動化制造,品質穩定產品不會產生危險氣體。
BB蓄電池采用鉛鈣六元合金板柵,涂膏成型的電極板,使得蓄電池大容量,長壽命;
鉛錫多元合金集流排,使得蓄電池內阻小,耐腐蝕,能經受長期浮充使用;
蓄電池采用*的AGM隔板,金屬吸收電解質,不留游離液體,順利完成氣體陰極吸收,可任意位置放置使用;
蓄電池采用硅氟橡膠密封安全帽,安全防爆,無腐蝕液體泄露;
蓄電池采用ABS塑料外殼,牢固耐老化;
蓄電池端子為鍍銅,接觸電阻小,不易生銹;
7、蓄電池分析電解質,自放電小。。
供應BB閥控式密封鉛酸蓄電池。采用澳洲99.99%的純鉛原料,日本高密度隔離板和安全閥,確保。
精密工藝及全線多道的檢測,免除電解液及氣體漏出。
特殊電解質配方,延長使用壽命,比一般電池循環壽命提升50%。
任意位置,任意行事均可安裝使用,不受空間限制,方便安全。
特殊格子體排列設計,精密的鑄造技術,強化極板耐腐蝕性。
生產過程采用全自動化電腦生產線及C.C.D.S充放電檢測系統,保證了產品*性。
低阻抗設計,自放電性低,容量保持及存儲時間在20℃下可達18個月以上。
全面
BB已經通過德國TUV機構ISO9001、ISO9002兩項質量認證認證及美國UL認證。產品全部經美國C.C.D.S電腦自動化系統輛次充放電檢驗。
環保先鋒
BB在美國有15000個電池回收站,并通過德國TUV機構ISO14001環保認證。成為同時通過ISO9001及ISO14001認證的電池廠商
服務的理念
BB客戶遍及40多個國家和地區。主要客戶有:APC、EXIDE、DELTEC、DELTA、SIEMENS、ERICSSON、PCM、MGR、BEST、LIEBERT等。
以上是供應BB蓄電池更換報價的詳細信息,
如果您對供應BB蓄電池更換報價的信息有什么疑問,
請與該公司進行進一步聯系,獲取供應BB更換報價的更多信息。
本公司主要銷售一下產品:
1:德國陽光蓄電池 2:圣陽蓄電池 3:大力神蓄電池 4:山特蓄電池5: BB蓄電池 7:湯淺蓄電池 8:友聯蓄電池9:松下蓄電池 10:山特UPS電源 11艾默生UPS電源 12:APCUPS電源 13:科士達蓄電池 14. 華科蓄電池 15.希爾特蓄電池(進口膠體)
---------------------------------------------------------------------------------------------------------
蓄電池售后服務:
1. 對售出的電池我們建立《顧客檔案》,實行跟蹤服務。
2. 電池售出后,實行隨時電話跟蹤,并執行每年至少一次的*巡檢,并向顧客報告蓄電池使用情況,讓顧客用的放心。
3. 發生顧客投訴時,一小時內提供解決方案。包括現場恢復方案及退貨處理方案,直到顧客滿意。宗旨是將客戶的麻煩降到小。
4. 正常情況下,退回電池在到貨兩周內出具檢測報告,確屬我司原因我司承擔責任;非我司電池原因,我們出具相應報告,對顧客的使用加以指導