供貨周期 | 現貨 | 規格 | 12V40AH |
---|---|---|---|
貨號 | 519 | 主要用途 | UPS電源 |
索瑞森蓄電池SGL12-40 12V40AH信號系統
參考價 | 面議 |
更新時間:2020-11-02 15:02:07瀏覽次數:218
聯系我們時請說明是化工儀器網上看到的信息,謝謝!
索瑞森蓄電池SGL12-40 12V40AH信號系統
索瑞森蓄電池SGL12-40 12V40AH信號系統
我司代理蓄電池產品,;如需詳細了解更多蓄電池技術參數及規格,請通過以上的聯系我;我們公司還設有經驗豐富的工程師團隊;對一些疑難解答和方案設計都有著多年的經驗。我們將熱誠為你服務!!!
------------------------------------------------------------------------------------------------
隨著索潤森電池在中國市場銷售額的迅速增長,產品度逐步提高,一些不法企業及公司冒充索潤森產品代理商在互聯網上銷售索潤森蓄電池,甚至有個別不良商戶給用戶提供的索潤森產品,給用戶在使用過程中造成安全隱患和無形損失。我司作為美國索潤森蓄電池在中國市場的代理商,負責索潤森蓄電池在中國地區的推廣、銷售及售后服務等業務;我公司從未授權任何其它公司區域代理權及網絡銷售等,所以提醒廣大用戶如有索潤森蓄電池需求,請從正規渠道購買;對于盜用索潤森商標權、冒稱索潤森代理商的不法行為,我公司將保留使用法律手段來追究其責任。
Our company acting battery products,; If you need more details about the battery technical parameters and specification, please contact me through the above contact information; Our company also has experienced team of engineers; For some troubleshooting and scheme design has many years of experience. Welcome to call, we will sincerely service for you!!!!!!
SGL系列規格表
電池型號 | 標稱電壓 | 設計壽命 | 容量 | 外型尺寸 | 重量 | ||
| V | YEAR | C10 | L | W | H | KG |
SGL12-7 | 12 | 12 | 7 | 150 | 65 | 117 | 2.7 |
SGL12-12 | 12 | 12 | 12 | 181 | 77 | 167 | 5.3 |
SGL12-18 | 12 | 12 | 18 | 165 | 125 | 175 | 8.7 |
SGL12-24 | 12 | 12 | 24 | 165 | 125 | 175 | 9.3 |
SGL12-30 | 12 | 12 | 30 | 197 | 165 | 170 | 12.6 |
SGL12-40 | 12 | 12 | 40 | 225 | 138 | 211 | 16.5 |
SGL12-50 | 12 | 12 | 50 | 350 | 167 | 179 | 20.2 |
SGL12-65 | 12 | 12 | 65 | 260 | 168 | 214 | 25.0 |
SGL12-80 | 12 | 12 | 80 | 306 | 169 | 214 | 29.5 |
SGL12-100 | 12 | 12 | 100 | 409 | 176 | 225 | 37.0 |
SGL12-120 | 12 | 12 | 120 | 485 | 172 | 240 | 43.0 |
SGL12-150 | 12 | 12 | 150 | 530 | 207 | 217 | 54.0 |
SGL12-200 | 12 | 12 | 200 |
| 269 | 223 | 78.0 |
然而,*的基礎設施配置并未能帶給數據中心更為高效的運行,數據中心運維管理的弊病進一步凸顯。在數據中心里,基礎設施實際上包含了兩個方面,一個是服務器、存儲、交換機這類的支撐企業業務運作的核心IT設備,此部分設備由專門分配的IT運維人員管理;另一部分是支撐上述IT設備運行的UPS、空調等輔助系統,由相應的運維人員管理。然而,多年的實踐表明,兩部分運維人員并不能形成很好地配合。IT運維人員更多地只關注了IT技術問題的解決,而為另一部分管理人員所不屑,只將IT設備作為普通的建筑設施來看,同UPS、空調等輔助系統處于同樣的管理等級。兩部分管理人員的管理權之爭問題在大型數據中心建設上更加凸顯。
另外,數據中心的運維透明度低成為另一個新難題。在一般情況下,CEO很少具體管理數據中心事物,CIO會是實際的管理者。缺乏有效地數據中心智能管理系統,為CIO向CEO的匯報帶來一定難度,如PUE的控制、真實的能耗情況、運維中的隱性成本、進一步投資的可行性等等,使CEO很難了解具體情況從而做出合理的改善決策。
DCIM解決大型數據中心運維管理難題
數據中心管理的復雜性和約束在日漸增多,如能源和環境的制約,使未來數據中心的建設、管理比以往任何時候都更具挑戰。而DCIM(DataCenterInfrastructureManagement,數據中心基礎設施管理)正是在大型數據中心管理需求增加下的一個產物,通過采用統一的平臺,同時管理那些關鍵基礎設施如UPS、空調以及IT設備,如服務器、網關、路由、交換機等,并通過數據的分析和整合,大程度提升數據中心的運營效率,提高數據中心的高可靠性。諸如RagingWire、Datotel和Logicalis這樣的企業都在利用DCIM技術實現客戶高效的數據中心運行,很多IT*如IBM通過聯合艾默生、美國康普通過收購iTRACS等跨界方式開發集成DCIM解決方案。根據產業分析機構Gartner估計,DCIM當前的市場規模價值為4.5億美元,到2016年有望增長至17億美元,而2014年已經被很多業內人士譽為是DCIM年。
資料服務:
1、 隨產品提供產品使用說明書及安裝說明書。
2、 根據用戶要求設計安裝,并提供產品設計安裝圖紙。
3、 根據用戶要求提供產品的有關性能資料及各種特性曲線。
4、 提供培訓用戶所需的培訓教材及相關資料。
American SuoRunSen battery is the most superior properties in the world today a valve control type lead acid battery, without maintenance is also on the Chinese market at present only pure import battery. It is in use when stable performance, high reliability, long service life, has the following technical characteristics:
1, using solid gel electrolytes. Under the same volume, large capacity of electrolyte, heat capacity, heat dissipation ability strong, can avoid battery are prone to thermal runaway phenomenon. 's ability to adapt to the environment temperature (high and low temperature).
2, internal without free fluid, without the possibility of internal short circuit.
3, electrolyte concentration is low, weak of corrosion on the plate; Uniform concentration, there is no acid stratification phenomenon.
4, with no antimony alloy battery plates, the battery self-discharge rate is extremely low
美國索潤森蓄電池是目前世界上各項性能越的閥控式鉛一酸免維護蓄電池,也是目前中國市場上惟一純進口的蓄電池.它在使用時性能穩定,可靠性高,使用壽命長,具有以下的技術特點:
1、采用固體凝膠電解質。在同等體積下,電解質容量大,熱容量大,熱消散能力強,能避免一般蓄電池易產生的熱失控現象。對環境溫度的適應能力(高、低溫)強。
2、內部無游離的液體存在,無內部短路的可能。
3、電解質濃度低,對極板腐蝕弱;濃度均勻,不存在酸分層的現象。
4、采用無銻合金電池極板,電池自放電率極低,在20攝氏度下電池存放兩
年不需補充電。
5、采用滑動密閉技術
6、長時間放電能力及循環放電能力強.
7、采用高靈敏度低壓傘式氣閥(德國陽光公司),無滲液\鼓脹現象。
8、*的承受深放電及大電流放電能力,有過充電及過放電自我保護,電池在100%后仍可繼續接在負載上,在四周內充 電可恢復至原容量.),即允許由電化學反應必然產生的電池使用后期的的極柱生長,又能保證其* 的密封性能
DCIM背后的想法很簡單,但功能很強大:通過自我感知網絡組件,一個中央數據倉庫和智能處理系統,可以實現對數據中心的核心基礎設施實現自動實時管理。二十年前,DCIM的強大功能對于那幾平米的簡陋機房來說無疑是大材小用,然而當前,DCIM對于需要一個人管理管理2萬臺服務器的數據中心來說似乎是正當時,這也不難理解為何FACEBOOK為何會高調宣布要采用DCIM系統。不可否認,已經有越來越多地CIO正在認識到DCIM作為提高生產力的主要驅動力。Raritan為ChoiceHotels部署的DCIM系統已經證明,利用DCIM管理數據中心基礎設施,可以以減少網絡停機時間,優化電源和空間使用情況,并加快服務部署,同時還能提高安全性。
DCIM的日常IT任務
配置和業務部署:隨著數據中心設備的增加,高密度已經是數據中心關心的問題。當添置新設備時,管理人員需要尋找一個合適的空間,配備相應的電源,并且還需要考慮其他變數。因此,數據中心規劃變得越來越重要,如果有一套智能系統能根據自定義的變量進行篩選合適的位置并配備相應的服務,將會事半功倍。
板柵合金 低銻多元合金,自放電小,達到少維護狀態。電池極板正極板為管式結構,負極板為涂膏式結構。壽命長,性能可靠。隔板 微孔橡膠隔板和穿孔塑料隔板兩種,有效避免了短路現象的發生。電池槽、蓋:透明AS樹脂,可觀察內部情況,底部鞍橋有效避免活性物質脫落造成的短路。
密封結構膠粘密封,極柱部位采用機械密封和膠粘雙重密封,確保無漏液。防酸霧帽特制防酸霧帽,使酸霧通過防酸霧帽的濾氣罩過濾,安全可靠。電池性能體積小,比能量大,容量高,*放電可達95%以上。
注意事項:
不要將蓄電池正負端子短路,如短接,有發生蓄電池漏液,著火的危險。
將蓄電池裝入機器時,機器不要使用密封結構,如使用密封結構,有損壞機器和造成人身傷害的危險。
蓄電池的使用溫度范圍如下,如在此溫度范圍以外使用,會造成蓄電池性能,壽命降低,損壞及變形。 放電-15℃-50℃, 充電0℃-40℃,保管-15℃-40℃
請不要使用含有可塑劑的絕緣線。另外,請不要使用香蕉水,汽油,揮發油,油,油脂等有機溶濟和清洗劑。如使用這些物質接觸電池殼,使用池殼裂開或發生裂紋,造成電池漏液,著火等。
使用過的電池也要回收利用,請不要丟棄。請聯系蔽公司或服務公司。
蓄電池內部保有稀硫酸。蓄電池中漏出的液體沾到皮膚和衣服時,請用大量水沖洗。
不要分解,改造和破壞蓄電池。
庫存狀況: 有貨當日出貨
支付方式: 對公/私銀行電匯,支付寶
配送方式:北京本市可以免費送貨上門,其余省市地區均可3天到達,5只(含)以上可免運費,低于5只酌情收取成本費。
全國代理全國聯保質保三年
【華 北】 北京市 天津市 河北省 山西省 內蒙古自治區
【東 北】 遼寧省 吉林省 黑龍江省
【華 東】 上海市 江蘇省 浙江省 安徽省 福建省 江西省 山東省
【中 南】 河南省 湖北省 湖南省 廣東省 廣西壯族自治區 海南省
【西 南】 重慶市 四川省 貴州省 云南省 西藏自治區
【西 北】 陜西省 甘肅省 青海省 寧夏回族自治區 新疆維吾爾自治區
【港澳臺】 香港特別行政區 澳門特別行政區 中國臺灣省
由于網頁資源有限,具體電池型號、參數、價格咨詢請致電。另外我們還為客戶提供技術咨詢服務,說出您的負載、延時時間等,我們會有的工程師為您提供ups電源、電池解決方案,讓您真正的后顧無憂!