聯(lián)系電話
北京祥生興業(yè)科技有限公司
參考價: | 面議 |
- 72038 72039 產(chǎn)品型號
- CHROMSYSTEMS 品牌
- 代理商 廠商性質(zhì)
- 所在地
訪問次數(shù):85更新時間:2024-09-19 13:57:34
- 聯(lián)系人:
- 張先生
- 電話:
- 13681184382
- 手機(jī):
- 13681184382
- 地址:
- 北京市北京經(jīng)濟(jì)技術(shù)開發(fā)區(qū)同濟(jì)中路甲7號18幢A座1010
掃一掃訪問手機(jī)商鋪
溫馨提示:僅用于科研,不可用于臨床治療
- 供應(yīng)商:
祥生興業(yè)
- 規(guī)格:
7 x 3 ml (lyoph.)
- 11-Deoxycortisol
- 21-Deoxycortisol
- Aldosterone
- Corticosterone
- Cortisol
- Cortisone
- 11-Deoxycorticosterone
- 17-OH-progesterone
- Androstenedione
- Dehydroepiandrosterone (DHEA)
- Dehydroepiandrosterone sulfate (DHEA-S)
- Dihydrotestosterone (DHT)
- Estradiol
- Progesterone
- Testosterone
72038 6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1
Order no.: 72038
MassChrom® Steroids in Serum/Plasma - LC-MS/MS
DESCRIPTION
6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1, lyophilised
For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.
These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 1 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.
TECHNICAL DATA
Method of Analysis
LC-MS/MSContent
7 x 3 ml (lyoph.)Parameter
11-Deoxycortisol, 21-Deoxycortisol, Aldosterone, Corticosterone, Cortisol, CortisoneConcentrations
Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.
Substance | Unit | Calibrator 1 | Calibrator 2 | Calibrator 3 | Calibrator 4 | Calibrator 5 | Calibrator 6 | Blank Calibrator |
---|---|---|---|---|---|---|---|---|
Aldosterone | µg/l | 0.024 | 0.084 | 0.161 | 0.319 | 0.816 | 4.23 | n.d. (< 0.014) |
Corticosterone | µg/l | 0.455 | 0.997 | 2.39 | 4.86 | 14.9 | 48.1 | n.d. (< 0.175) |
Cortisol | µg/l | 9.02 | 20.1 | 39.1 | 77.5 | 149 | 290 | n.d. (< 1.52) |
Cortisone | µg/l | 0.942 | 2.56 | 4.93 | 9.66 | 19.5 | 38.8 | n.d. (< 0.148) |
11-Deoxycortisol | µg/l | 0.088 | 0.484 | 0.938 | 1.87 | 4.66 | 13.7 | n.d. (< 0.030) |
21-Deoxycortisol | µg/l | 0.070 | 0.163 | 0.257 | 0.513 | 1.56 | 4.69 | n.d. (< 0.027) |
n.d. = not determined, analytes under LOQ
Reconstitution
Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.
Storage conditions
Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.
72039 6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2
Order no.: 72039
MassChrom® Steroids in Serum/Plasma - LC-MS/MS
DESCRIPTION
6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2, lyophilised
For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.
These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 2 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.
TECHNICAL DATA
Method of Analysis
LC-MS/MSContent
7 x 3 ml (lyoph.)Parameter
11-Deoxycorticosterone, 17-OH-progesterone, Androstenedione, Dehydroepiandrosterone (DHEA), Dehydroepiandrosterone sulfate (DHEA-S), Dihydrotestosterone (DHT), Estradiol, Progesterone, TestosteroneConcentrations
Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.
Substance | Unit | Calibrator 1 | Calibrator 2 | Calibrator 3 | Calibrator 4 | Calibrator 5 | Calibrator 6 | Blank Calibrator |
---|---|---|---|---|---|---|---|---|
Androstenedione | µg/l | 0.202 | 0.408 | 0.820 | 1.54 | 5.09 | 15.3 | n.d. (< 0.020) |
11-Deoxycorticosterone | µg/l | 0.049 | 0.098 | 0.146 | 0.288 | 0.721 | 2.80 | n.d. (< 0.023) |
DHEA | µg/l | 1.04 | 5.25 | 10.3 | 15.6 | 30.7 | 60.7 | n.d. (< 0.229) |
DHEAS | µg/l | 117 | 558 | 1097 | 2066 | 3949 | 5887 | n.d. (< 24.4) |
Dihydrotestosterone | µg/l | 0.061 | 0.111 | 0.257 | 0.501 | 0.942 | 1.50 | n.d. (< 0.042) |
Estradiol | µg/l | 0.043 | 0.105 | 0.260 | 0.530 | 1.59 | 5.33 | n.d. (< 0.026) |
17-Hydroxyprogesterone | µg/l | 0.097 | 0.498 | 1.01 | 2.00 | 3.98 | 15.0 | n.d. (< 0.040) |
Progesterone | µg/l | 0.180 | 0.805 | 2.11 | 5.27 | 10.3 | 26.0 | n.d. (< 0.030) |
Testosterone | µg/l | 0.055 | 0.250 | 0.982 | 2.94 | 5.82 | 11.6 | n.d. (< 0.005) |
Reconstitution
Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.
Storage conditions
Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.