聯(lián)系電話
北京祥生興業(yè)科技有限公司
參考價(jià): | 面議 |
- 2009 產(chǎn)品型號(hào)
- CHROMSYSTEMS 品牌
- 代理商 廠商性質(zhì)
- 所在地
訪問(wèn)次數(shù):74更新時(shí)間:2024-09-19 13:53:22
- 聯(lián)系人:
- 張先生
- 電話:
- 13681184382
- 手機(jī):
- 13681184382
- 地址:
- 北京市北京經(jīng)濟(jì)技術(shù)開(kāi)發(fā)區(qū)同濟(jì)中路甲7號(hào)18幢A座1010
- 個(gè)性化:
- www.xiangshengbio.com
掃一掃訪問(wèn)手機(jī)商鋪
溫馨提示:僅用于科研,不可用于臨床治療
- 保存條件:
低溫
- 英文名:
Metanephrines Urine Calibration Standard (lyoph.), 5 x 5 ml
- 庫(kù)存:
大量
- 供應(yīng)商:
祥生興業(yè)
- 規(guī)格:
5 x 5 ml
Metanephrines Urine Calibration Standard
Concentrations (example)
Please note: All concentrations shown here are exemplatory. They do not reflect real data for the described products. Actual concentrations depend on the production lot of each product and can exclusively be found in the product information leaflet. Please ask for these product information leaflets or download them from the service site of the Chromsystems website.
Substance | Unit | Concentration Urine Calibration Standard | Concentration Aqueous Calibration Standard |
---|---|---|---|
Normetanephrine | µg/l nmol/l | 736 4020 | 250 1365 |
Metanephrine | µg/l nmol/l | 288 1459 | 250 1268 |
3-Methoxytyramine | µg/l nmol/l | 300 1793 | 250 1495 |
Instructions
These Chromsystems calibrators are designed to monitor the accuracy and precision of analytical procedures for the quantitative determination of metanephrines in urine.
The lyophilised urine calibration standard (order no. 2009) is based on human urine and should be used routinely according to the instructions accompanying the assay procedure being used. While following these instructions, the urine calibration standard is to be prepared and injected in the same manner as a patient specimen. .
The aqueous calibration standard (order no. 2023) is injected directly into the HPLC system without sample preparation.
Reconstitution
(Urine Calibration Standard)
Remove the metal seal and rubber stopper from the vial. Add exactly 5.0 ml of double distilled water (possibly HPLC-grade) into the vial. Replace the stopper on the vial and allow to sit for 10 to 15 minutes at room temperature. Swirl the vial to dissolve the contents until homogeneity.
Storage conditions
(Urine Calibration Standard)
Stored at <-18 °C unopened calibration standards are stable until the expiry date which is stated on the vial labels. The reconstituted calibration standard should be stored tightly capped at +2 to +8 °C. The prepared calibration standard sample has the same stability as a fresh urine specimen. Use the known storage conditions for the different components. For specific information about the stability of the individual components please refer to the instructions of your test instruction manual. Generally the calibration standard can be stored for two days at +2 to +8 °C. If the calibration standard cannot be analysed within this period, it should be aliquoted and stored frozen at <-18 °C.
Ordering information
2009 | Metanephrines Urine Calibration Standard (lyoph.) | 5 x 5 ml |
2023 | Calibration Standard for analysis of metanephrines in urine (primary standard solution) | 10 ml |
Additionally available:
0040 | Endocrine Urine Control, normal range | 10 x 8 ml |
0050 | Endocrine Urine Control, pathological range | 10 x 8 ml |