當前位置:上海境宣實業有限公司>>日本光明北川式氣體檢測管>>氣體快速檢測管>> 119U甲醇CH3OH氣體檢測管119U METHYLALCOHOL(METHANOL)20-1000ppm
室內空氣甲醛檢測管No.713 FORMALDEHYDE 0.01-0
氯乙烯CH2=CHCl氣體測毒管132SC VINYL CHLORID
氯乙烯CH2=CHCl氣體檢知管132SB VINYL CHLORID
甲醇CH3OH氣體檢測管119U METHYL ALCOHOL(METHANOL) 20-1000ppm
Tube 19U
1. PERFORMANCE
1) Measuring range :20-1,000 ppm
Number of pump strokes 1(100ml)
2) Sampling time :1.5 minutes/1 pump stroke
3) Detectable limit :5 ppm
4) Shelf life :2 years
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary(0~20℃)(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change :Yellow→Pale blue
2. RELATIVE STANDARD DEVIATION
RSD-low:15% RSD-mid.:10% RSD-high:10%
3. CHEMICAL REACTION
Potassium dichromate is reduced
CH3OH+Cr6++H2SO4→Cr3+
4. CALIBRATION OF THE TUBE
GAS CHROMATOGRAPHY
5. INTERFERENCE AND CROSS SENSITIVITY
20
50
100
200
400
600
800
1000
ppm
GAS To pump
DEHUMIDIFIER
(White)
119U
METHYL ALCOHOL
(METHANOL)
Substance Interference Coexistence
Alcohols FIG.1 Similar stain is produced. Higher readings are given.
Esters FIG.2 〃
Paraffin (morefi nth haynd Cro3c)arbons Whole reagent is changed to Brown. 〃
Aromatic hydrocarbons 〃〃
Ketones 〃〃
Halogenated hydrocarbons 〃〃
0
500
1000
Ethanol〔ppm〕?
FIG.1 Influence of Ethanol
Methanol indicating value 〔ppm〕
500
Coexistence
Interference
0
500
1000
Ethyl acetate〔ppm〕?
FIG.2 Influence of Ethyl acetate
Methanol indicating value 〔ppm〕
500
TEMPERATURE CORRECTION TABLE
Scale True Concentration (ppm)
Readings 0℃ 10℃ 20-40℃
(ppm) (32°F) (50°F) (68-104°F)
1000 1200 1100 1000
800 960 880 800
600 600 660 600
400 480 440 400
200 240 220 200
100 120 110 100
50 60 50 50
20 24 20 20