當前位置:上海境宣實業有限公司>>日本光明北川式氣體檢測管>>氣體快速檢測管>> 167S硒化氫H2Se氣體檢測管167S HYDROGEN SELENIDE 1-600ppm
室內空氣甲醛檢測管No.713 FORMALDEHYDE 0.01-0
氯乙烯CH2=CHCl氣體測毒管132SC VINYL CHLORID
氯乙烯CH2=CHCl氣體檢知管132SB VINYL CHLORID
硒化氫H2Se氣體檢測管167S HYDROGEN SELENIDE 1-600ppm
Tube 67S
1. PERFORMANCE
1) Measuring range :5-600 ppm 1-120 ppm
Number of pump strokes 1(100ml) 5(500ml)
2) Sampling time :1.5 minutes/1 pump stroke
3) Detectable limit :0.5 ppm(500ml)
4) Shelf life :1 year
5) Operating temperature :0~40℃
6) Reading :Direct reading from the scale calibrated by 1 pump stroke
7) Colour change :Pale yellow→Dark brown
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:10% RSD-high:5%
3. CHEMICAL REACTION
By reacting with Gold chloride(III), Colloidal gold is liberated.
H2Se+AuCI3(III)→Au
4. CALIBRATION OF THE TUBE
STANDARD GAS CYLINDER METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
GAS To pump
600
550
500
450
400
350
300
250
200
150
100
50
10
5
100ml
ppm
????
????
167S HYDROGEN SELENIDE
Substance ppm Interference ppm Coexistence
Acetylene 3% Higher readings are given.
Carbon monoxide 0.1% 〃
Sulphur dioxide Pale blue stain is produced. 〃
Hydrogen sulphide 10 Brown stain is produced. 〃
Mercury vapours Similar stain is produced.
Arsine 〃10 〃
Iron carbonyl 〃10 〃
Nickel carbonyl 〃10 〃
(NOTE)
When the concentration is below 5 ppm, 5 pump strokes can be used to determine the lower concentration.
Following formula is available for the actual concentration.
Actual concentration=1/5×Reading value