當前位置:上海境宣實業有限公司>>日本光明北川式氣體檢測管>>氣體快速檢測管>> 104SA酒精(乙醇)C2H5OH氣體檢測管104SA ETHYL ALCOHOL(ETHANOL)
室內空氣甲醛檢測管No.713 FORMALDEHYDE 0.01-0
氯乙烯CH2=CHCl氣體測毒管132SC VINYL CHLORID
氯乙烯CH2=CHCl氣體檢知管132SB VINYL CHLORID
酒精(乙醇)C2H5OH氣體檢測管104SA ETHYL ALCOHOL(ETHANOL)0.05-5.0%
Tube 04SA
1. PERFORMANCE
1) Measuring range :0.05-5.0%
Number of pump strokes 1(100ml)
2) Sampling time :1.5 minutes/1 pump stroke
3) Detectable limit :100 ppm
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change :Yellowish orange→Pale green(The top of discoloured lauer is Brown, but read
at the top Pale green.)
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:5% RSD-high:5%
3. CHEMICAL REACTION
Chromium oxide is reduced.
C2H5OH+Cr6++H2SO4→Cr3+
4. CALIBRATION OF THE TUBE
GAS CHROMATOGRAPHY
5. INTERFERENCE AND CROSS SENSITIVITY
GAS To pump
5.0
4.0
3.0
2.0
1.0
0.5
0.1
0.05
%
DEHUMIDIFIER
(White)
???????? ??
104SA
ETHYL ALCOHOL
(ETHANOL)
Substance Interference Coexistence
Paraffin hydrocarbons
(over C3) Similar stain is produced. Higher reading are given.
Alcohols 〃〃
Esters 〃〃
Ketones 〃〃
Aromatic hydrocarbons 〃〃
If the top of discolouration by
Halogenated hydrocarbons Pale brown stain is produced. Ethanol can be obtained, the
accuracy of readings is not
affected.
TEMPERATURE CORRECTION TABLE
Scale True Concentration (%)
Readings 0℃ 10℃ 20℃ 30℃ 40℃
(%) (32°F) (50°F) (68°F) (86°F) (104°F)
5.0 - - 5.0 3.9 3.2
4.0 - - 4.0 3.2 2.6
3.0 - - 3.0 2.4 2.0
2.0 - - 2.0 1.6 1.3
1.0 - 1.9 1.0 0.8 0.7
0.5 - 0.8 0.5 0.4 0.3
0.3 0.9 0.4 0.3 0.3 0.2
0.1 0.1 0.1 0.1 0.1 0.1