供貨周期 | 現貨 |
---|
我司所售的蓄電池保證是原廠原裝產品,,簽訂合同,并提供,
38AH以上出現非人為質量問題三年內免費更換同等型號的全新電池,請廣大客戶放心采購!
參考價 | 面議 |
更新時間:2020-11-02 15:04:23瀏覽次數:791
聯系我們時請說明是化工儀器網上看到的信息,謝謝!
Shimastu鉛酸蓄電池NP24-12渦輪風力12V24AH
Shimastu鉛酸蓄電池NP24-12渦輪風力12V24AH
我司代理蓄電池產品,;如需詳細了解更多蓄電池技術參數及規格,請通過以上的我;我們公司還設有經驗豐富的工程師團隊;對一些疑難解答和方案設計都有著多年的經驗。,我們將熱誠為你服務!!!
-------------------------------------------------------------------------------
The paralleled cells of SHIMASTU battery can be installed on the wood or steel stacks, but it is better to install on the special stacks.
There is no technical reason for limiting the number of strings but for practical installation reasons. It is recommended not allowed to exceed 3 strings in parallel especially if the battery is used in high discharge rates(backup time less than 15 mins)
Shimastu電子科技有限公司,一個的密封鉛酸(SLA)電池的專業廠家,引進日本AGM公司的技術基礎。Shimastu一直在研究、開發、生產和營銷SLA電池自2001年以來。采用*的技術過程從日本技術和現代化的生產設備和檢測設備,Shimastu一直為客戶提供SLA的NP系列電池使用壽命長,質量可靠,性能穩定。
另外,企業經常會使用飛輪來作為補充電池,而不是將其作為替換品。95%以上的停電事故實際只持續幾秒鐘,而更嚴重的故障通常每年會發生幾次。混合解決方案中,飛輪在發生短暫的停電事故期間提供備用電源,電池可處理更長的停電事故,可延長電池的使用壽命,這也可能會減少UPS設備使用壽命期間內的電池更換次數。
四、替代選項三:超級電容器
超級電容器(ultracapacitor)也被稱為supercapacitors。其是的,密度*,高速的能量存儲選項。它們是非機械的替代方案,通常含有無毒的碳基材料,如活性炭和石墨烯。他們是一個非機械的選擇替代方案。
1、優點:
緊湊的外形:像飛輪一樣,超級電容器比鉛酸電池更小更輕。
低環境影響:超級電容器(以及飛輪)不含硫酸,從而緩解了處理有毒化學品的擔憂。
充電不會影響其使用壽命:您企業數據中心也可以在不影響容量、性能或使用壽命的情況下,隨時放電并再充電。
無需維護:超級電容器是一種沒有移動部件的固態器件,因此不需要維護。
2、缺點:
有限的備份時間:像飛輪一樣,超級電容器在極短的時間內提供電力。直到近超級電容器也僅僅只提供了十秒鐘的待機能量。現代化的超級電容器系統現在可以提供長達30秒的備份時間,使其成為飛輪的非機械替代品。
成本較高:超級電容器的成本也比鉛酸電池高。平均而言,超級電容器的前期成本大約是鉛酸電池的兩倍。
3、未來的市場發展前景展望
未來三到五年內,價格將繼續下降。而隨著用戶對較短的備份時間的適應,用戶對其的需求將會增加。
五、替代選項四:燃料電池
與電池不同,燃料電池發電而不是儲存電源。燃料電池基本上是一種將燃料(通常是氫氣或天然氣)轉化為能量的電化學裝置。然而,與也將燃料轉化為能量的內燃機不同,氫動力燃料電池排出的燃燒產物是水。
因此,從汽車制造商到電力公司,再到UPS制造商,每家企業都在測試其應用中的燃料電池,或者調查其使用情況。一些更*的數據中心客戶使用燃料電池與2N或雙總線配置中的公用電源相結合。
1、優點:
1)環保:與鉛酸電池不同,燃料電池對環境幾乎沒有危險。
2)長備份時間:只要您企業數據中心具有足夠的燃料,燃料電池就會持續供應緊急電力。這意味著平均燃料電池能夠比鉛酸電池或本文中所討論的其他三種備用電源中的任何一種提供更多的待機能量。
2、缺點:
成本較高:盡管近年來價格大幅下降,但燃料電池仍然比鉛酸電池昂貴得多。電力成本是一個重要的考慮因素,因為典型的燃料電池只有85%的效率。
安全問題:燃料源是易燃的,因此企業數據中心對于燃料電池必須非常小心地安裝、存放和提供支持。
延遲開始時間:通常需要大約30秒才能使燃料電池啟動并以全功率運行。因此,基于燃料電池的UPS設備通常會使用小型電池在啟動期間提供備用電源。
3、未來的市場發展前景展望
燃料電池制造商們正在試驗氫氣的替代品,這樣可以提高安全性,并提高采用率。然而,盡管燃料電池成本在下降,但它們仍然遠高于鉛酸電池,并且可能會持續一段時間。因此,燃料電池在未來幾年可能只能看作是UPS備用電源的有限部署,但可能會在分布式能源環境中看到更多的部署,成為這些環境的主要電源。
Shimastu包括30技術人員超過350人,位于廣東省珠江三角洲,中國。Shimastu已經向世界輸出SLA電池在其自己的品牌“Shimastu”或OEM訂單。Shimastu每個月可以生產150000臺以上的電池,平均30多從IQC對FQC質量控制檢查。到目前為止,Shimastu獲得ISO14000,UL和CE證書。
蓄電池應用領域與分類:
◆ 免維護無須補液; ● UPS不間斷電源;
◆ 內阻小,大電流放電性能好; ● 消防備用電源;
◆ 適應溫度廣; ● 安全防護報警系統;
◆ 自放電小; ● 應急照明系統;
◆ 使用壽命長; ● 電力,郵電通信系統;
◆ 荷電出廠,使用方便; ● 電子儀器儀表;
◆ 安全防爆; ● 電動工具,電動玩具;
◆ *配方,深放電恢復性能好; ● 便攜式電子設備;
◆ 無游離電解液,側倒仍能使用; ● 攝影器材;
◆ 產品通過CE,ROHS認證,所有電池 ● 太陽能、風能發電系統;
符合國家標準。 ● 巡邏自行車、紅綠警示燈等。
There is only part technical specification on our website,聽 |
Model | Nominal Voltage | Nominal Capacity | Dimensions | Ht.Over Terminal | Weight Approx(kg) | Terminals | Accessories | |||||||||||||||
L | W | H | ||||||||||||||||||||
in | mm | in | mm | in | mm | in | mm | kg | lb | |||||||||||||
FA55-12 | 12 | 55 | 10.91 | 277 | 4.17 | 106 | 8.74 | 222 | 8.74 | 222 | 18 | 39.67 | B04 | · download | ||||||||
FA75-12 | 12 | 75 | 22.12 | 562 | 4.48 | 114 | 7.4 | 188 | 7.4 | 188 | 29 | 63.92 | B04 | · download | ||||||||
FA100-12 | 12 | 100 | 15.51 | 394 | 4.29 | 109 | 11.22 | 285 | 11.22 | 285 | 35 | 77.14 | B04 | · download | ||||||||
FA105-12 | 12 | 105 | 19.69 | 507 | 4.29 | 109 | 9.37 |
| 37 | 238 | 36 | 79.34 | B04 | · download | ||||||||
FA120-12 | 12 | 120 | 21.69 | 551 | 4.29 | 109 | 9.41 | 239 | 9.41 | 239 | 37.5 | 82.65 | B04 | · download | ||||||||
FA150-12 | 12 | 150 | 21.69 | 551 | 4.29 | 109 | 11.3 | 287 | 11.3 | 287 | 47.5 | 104.69 | B04 | · download | ||||||||
FA180-12 | 12 | 180 | 22.05 | 560 | 4.92 | 125 | 12.44 | 316 | 12.44 | 316 | 57 | 125.63 | B04 | · downloa | ||||||||
| ||||||||||||||||||||||
PHYSICAL SPECIFICATION | ||||||||||||||||||||||
Nominal Voltage Nominal Capacity (10HR) | 12V 9Ah |
| ||||||||||||||||||||
Dimension | Length Width Container Height Total Height | 152±1mm (5.98 inches) 87±1mm (3.42 inches) 107±1mm (4.21 inches) 107±1mm (4.21 inches) | ||||||||||||||||||||
Weight | Approx. 3.1Kg (6.83lbs) | |||||||||||||||||||||
Standard Terminal | F1-Fasten Tab M01 | |||||||||||||||||||||
| ||||||||||||||||||||||
ELECTRICAL SPECIFICATION | ||||||||||||||||||||||
Characteristics | Discharge curves @ 25℃ (77 °F) | |||||||||||||||||||||
Capacity | 10 hour rate (0.9A) 5 hour rate (1.53A) 1hour rate (5.4A) | 9Ah 7.6Ah 5.4Ah |
| |||||||||||||||||||
Capacity affected by temperature | 40℃ (104 0F) 25℃ (77 0F) 0℃ (32 0F) | 102% 100% 85% | ||||||||||||||||||||
Internal Resistance | Full charged battery (25℃,77 0F) 10mΩ | |||||||||||||||||||||
Discharge at 72A for 5 seconds (-10℃) | ≥9.3V | |||||||||||||||||||||
Discharge at 72A for 90seconds (-10℃) | ≥6V | |||||||||||||||||||||
Constant Voltage Charge | Cycle | Initial Charging Current less than 2.7A Voltage 14.4~15.0V at 25℃ (77 0F ) Temperature Coefficient –5mV/℃ | ||||||||||||||||||||
Standby | No limit on Initial Charging Current Voltage 13.5~13.8V at 25℃ (77 0F ) Temperature Coefficient –3.3mV/℃ |
供方責任:
38AH(含38AH)以上蓄電池,質保期為三年,三年出現任何非人為質量問題,免費更換全新的同品牌同型號規格的蓄電池.非人為質量問題包括:運輸過程中造成的電池破損、鼓包、漏液、電池電壓范圍異常、接線端子變形等.
本公司還供應以下產品:
湯淺蓄電池、松下蓄電池、理士蓄電池、賽特蓄電池、圣陽蓄電池、雙登蓄電池、非凡蓄電池、科士達蓄電池、梅蘭日蘭蓄電池、三瑞蓄電池、大力神蓄電池、凱鷹蓄電池、南都蓄電池、光宇蓄電池、風帆蓄電池、臥龍燈塔蓄電池、德國陽光蓄電池、美國山特電源、APCUPS不間斷電源
專業的ups不間斷電源鉛酸免維護蓄電池供應商及服務商
質量是企業的生命,服務是企業的根本。
穩定性、敏捷性和運營效率數據中心IT基礎設施目標。數據中心穩定運營意味著數據中心運營商和管理人員減少了應對電力中斷和消防火災等耗費的時間和資源,可以將更多的時間和資料構建新平臺或優化現有平臺。
企業中的數據中心運營實踐從簡單的IT事件監控發展到復雜的任務,如映射網絡連接和移除未充分利用的服務器。
行業專家為企業的數據中心運營提供了更好的指導,并提供有實踐和正確管理工具的提示和建議。在數據中心運營實踐清單這個清單中提供了10個技巧,其中包括管理IT資產的實踐,防止IT資源浪費,配置基設施,處理應用程序遷移,以及支持和執行其他日常數據中心操作。
1.良好地處理所有的應用程序
在現代數據中心中,應用支持是重要的工作。IT運營團隊面臨一個艱巨的任務,監督應用程序遷移,維護原有系統以及將新的多樣化應用程序加入IT基礎設施。
2.使用自己的IT基礎設施工具
IT基礎設施監控工具對容量使用、瓶頸、訪問嘗試等提供了深入的了解。為了有效地使用它們,從一個合理的和可實現的項目范圍開始,探索人工智能啟用的特性。
3.關注配置管理
配置管理工具的實施需要IT基礎設施和開發團隊的支持,但穩定性和快速更新的回報是值得的。分析師KurtMarko建議IT組織對各組之間的配置管理工具進行標準化,以簡化軟件交付和支持。
4.遵從安全實踐
如果可以阻止未經授權的人員或未知人員訪問存儲在IT基礎設施上的企業信息,那么平穩的數據中心運營意味著可以通過CISSPCBK*(ISC)2指南(ISC)2編制的安全攻擊測試,使這些關鍵系統免受可能的攻擊者的威脅。
5.充分利用自己的服務器
數據中心運營實踐圍繞使現有基礎設施盡可能地提高高性能和高效運行。僵尸服務器通常占組織中運行能力的30%,面對嚴格的數據中心管理,人們需要遵循數據中心設計和實施專家RobertMcFarlane的建議,消除僵尸服務器,并提高服務器性能。
6.鎖定IT資產
作為工作人員,知道今年哪些操作系統和應用程序許可證會過期嗎?網絡上有多少項目?每個群集中的可用服務器容量是否高可用?技術編寫人員StephenJ.Bigelow解釋說,當所有IT資產得到妥善管理時,數據中心運營運行得更加順暢。
7.保持服務器密實踐
云計算服務提供商和網絡級組織為服務器密度和管理方面的數據中心運營商樹立了榜樣。新聞作家RobertGates表示,云狀冗余、虛擬化存儲和網絡,以及超融合基礎設施改變了現代數據中心運營的游戲規則。
8.擁抱和規范變革
變化是一種常量,所以要使變更管理*。變更管理過程是一個至關重要的數據中心操作踐,組織應通過各種工具為其提供支持。變更管理意味著后端穩定性,這在IT前端的靈活性和靈活性方面得到了回報。不確定如何開始或在哪里修復損壞的系統?ITAdamFowler表示,企業通過各種方式來了解和改進變化,從而引導數據中心團隊。
9.將災難恢復作為優先事項
災難恢復是很少使用的基本服務。數據中心運營商經常讓文檔、流程和程序變得過時,這使得其停機之后,恢復過程更長,這是一個令人沮喪的過程。IT顧問和審計員PaulKirvan說,工作人員要勤于實踐,并了解每個數據中心在其權限范圍內的危險性,以免在災難事件真正發生時毫無準備。
10.調整機架級電源容量
服務器在功耗和利用率方面差異很大,這些因素會影響每個機架消耗的功率。企業需要估算機架中的功率消耗,以便插入新設備,為額外的服務器和陣列規劃空間或重新平衡功率負載。