供貨周期 | 現貨 |
---|
我司所售的蓄電池保證是原廠原裝產品,,簽訂合同,并提供,
38AH以上出現非人為質量問題三年內免費更換同等型號的全新電池,請廣大客戶放心采購!
參考價 | 面議 |
更新時間:2020-11-02 15:04:23瀏覽次數:663
聯系我們時請說明是化工儀器網上看到的信息,謝謝!
Shimastu鉛酸蓄電池NP80-12動力工具12V80AH
Shimastu鉛酸蓄電池NP80-12動力工具12V80AH
我司代理蓄電池產品,;如需詳細了解更多蓄電池技術參數及規格,請通過以上的我;我們公司還設有經驗豐富的工程師團隊;對一些疑難解答和方案設計都有著多年的經驗。,我們將熱誠為你服務!!!
-------------------------------------------------------------------------------
The paralleled cells of SHIMASTU battery can be installed on the wood or steel stacks, but it is better to install on the special stacks.
There is no technical reason for limiting the number of strings but for practical installation reasons. It is recommended not allowed to exceed 3 strings in parallel especially if the battery is used in high discharge rates(backup time less than 15 mins)
通過在輸入端使用小型電感/電容(LC)低通濾波器,即使輸入電感中的適度di/dt變化也不會*線路電壓,只需通過同一個LC濾波器在輸出電壓下對其進行濾波即可。
磁性元件材料的規格和重量比較
下圖7顯示了使用無變壓器設計所實現的規格和重量減輕的示例,該圖顯示了常規拓撲UPS的“磁性材料封裝”(magpak)。包括輸出變壓器、輸入線路電感器、直流母線扼流圈、輸出濾波電感器和輸入諧波濾波電感器。其不僅非常重,而且還造成了整個單元的規格尺寸非常大。當進行相互比較時,傳統組件與新型無變壓器技術的規格尺寸和重量差異在視覺上相當明顯。
圖7:用于275kVAUPS系統的磁性封裝材料(magpak)的相對規格尺寸實例。
圖8:用于無變壓器拓撲的完整動力系統的一半的電感器。
這些電感器被焊接到功率印刷電路板(PCB)上,并以一小部分的規格尺寸、重量和成本安裝到鋁制的U型通道機箱。圖9顯示了一個終端視圖。
圖9:無變壓器UPS中電感器的終端視圖。
在無變壓器UPS中,經常使用閉芯設計。在高電流和低電感的情況下,通常會產生大的氣隙。消除除核心中心以外的所有部分,也會導致凈透過率低,以及低核心材料采購。將繞組限制為只有兩層,并在磁芯和繞組之間引入空間,可以直接強制冷卻所有繞組。在?10KHz及以上時,實線會遭受過度的擦破和鄰近效應損失。憑借如此的冷卻效果,只需簡單的絞合線即可,而成本僅僅只是傳統多層絞合線的一小部分。鐵氧體磁芯產生非常低的損耗,并避免被繞組加熱。成對使用時,遠場可以減少,同時通過反平行配置定向獲得約15%的有用電感。
無變壓器UPS并不*相同
與基于變壓器的系統相比,無變壓器UPS具有許多優點,但它們并不*相同。當選擇一款無變壓器UPS用于其關鍵任務應用時,企業數據中心的決策者們應堅持該款無變壓器UPS必須具備以下特點:
1、體積小,重量輕。
無變壓器的UPS應該比基于變壓器的產品體積小得多,重量輕,不僅因為它們不包含笨重的變壓器。UPS還應具備小型磁性材料元件(如電感器、扼流圈和鐵氧體)以及氣流改進功能,以盡量減少散熱片的尺寸和重量,并減少冷卻所需的風扇數量。請注意,除了節省空間之外,這些增強的功能也可以提高機械的可靠性。
2、能夠從停止的Y型甚至HRG源操作。
應在安裝文檔中明確描述中性點的正確處理方式。應特別注意上游和下游的故障性能,并且UPS應能夠供給給諸如208/120VAC和400/230VAC的4線負載。
3、從高效率到傳統操作模式的短暫過渡時間。
由于在高效率和傳統操作之間轉換時不需要磁化輸出變壓器,所以無變壓器UPS應該能夠在大約2毫秒內完成轉換。大于10毫秒的轉換時間可能會對下游靜態交換機或受支持的IT設備本身造成問題。
結論
帶有小型輕量級濾波電感器的無變壓器拓撲結構,逆變器和整流器中的高性能IGBT以及*的控制策略可帶來更高的性能和價值。
Shimastu電子科技有限公司,一個的密封鉛酸(SLA)電池的專業廠家,引進日本AGM公司的技術基礎。Shimastu一直在研究、開發、生產和營銷SLA電池自2001年以來。采用*的技術過程從日本技術和現代化的生產設備和檢測設備,Shimastu一直為客戶提供SLA的NP系列電池使用壽命長,質量可靠,性能穩定。
Shimastu包括30技術人員超過350人,位于廣東省珠江三角洲,中國。Shimastu已經向世界輸出SLA電池在其自己的品牌“Shimastu”或OEM訂單。Shimastu每個月可以生產150000臺以上的電池,平均30多從IQC對FQC質量控制檢查。到目前為止,Shimastu獲得ISO14000,UL和CE證書。
蓄電池應用領域與分類:
◆ 免維護無須補液; ● UPS不間斷電源;
◆ 內阻小,大電流放電性能好; ● 消防備用電源;
◆ 適應溫度廣; ● 安全防護報警系統;
◆ 自放電小; ● 應急照明系統;
◆ 使用壽命長; ● 電力,郵電通信系統;
◆ 荷電出廠,使用方便; ● 電子儀器儀表;
◆ 安全防爆; ● 電動工具,電動玩具;
◆ *配方,深放電恢復性能好; ● 便攜式電子設備;
◆ 無游離電解液,側倒仍能使用; ● 攝影器材;
◆ 產品通過CE,ROHS認證,所有電池 ● 太陽能、風能發電系統;
符合國家標準。 ● 巡邏自行車、紅綠警示燈等。
There is only part technical specification on our website,聽 |
Model | Nominal Voltage | Nominal Capacity | Dimensions | Ht.Over Terminal | Weight Approx(kg) | Terminals | Accessories | |||||||||||||||
L | W | H | ||||||||||||||||||||
in | mm | in | mm | in | mm | in | mm | kg | lb | |||||||||||||
FA55-12 | 12 | 55 | 10.91 | 277 | 4.17 | 106 | 8.74 | 222 | 8.74 | 222 | 18 | 39.67 | B04 | · download | ||||||||
FA75-12 | 12 | 75 | 22.12 | 562 | 4.48 | 114 | 7.4 | 188 | 7.4 | 188 | 29 | 63.92 | B04 | · download | ||||||||
FA100-12 | 12 | 100 | 15.51 | 394 | 4.29 | 109 | 11.22 | 285 | 11.22 | 285 | 35 | 77.14 | B04 | · download | ||||||||
FA105-12 | 12 | 105 | 19.69 | 507 | 4.29 | 109 | 9.37 |
| 37 | 238 | 36 | 79.34 | B04 | · download | ||||||||
FA120-12 | 12 | 120 | 21.69 | 551 | 4.29 | 109 | 9.41 | 239 | 9.41 | 239 | 37.5 | 82.65 | B04 | · download | ||||||||
FA150-12 | 12 | 150 | 21.69 | 551 | 4.29 | 109 | 11.3 | 287 | 11.3 | 287 | 47.5 | 104.69 | B04 | · download | ||||||||
FA180-12 | 12 | 180 | 22.05 | 560 | 4.92 | 125 | 12.44 | 316 | 12.44 | 316 | 57 | 125.63 | B04 | · downloa | ||||||||
| ||||||||||||||||||||||
PHYSICAL SPECIFICATION | ||||||||||||||||||||||
Nominal Voltage Nominal Capacity (10HR) | 12V 9Ah |
| ||||||||||||||||||||
Dimension | Length Width Container Height Total Height | 152±1mm (5.98 inches) 87±1mm (3.42 inches) 107±1mm (4.21 inches) 107±1mm (4.21 inches) | ||||||||||||||||||||
Weight | Approx. 3.1Kg (6.83lbs) | |||||||||||||||||||||
Standard Terminal | F1-Fasten Tab M01 | |||||||||||||||||||||
| ||||||||||||||||||||||
ELECTRICAL SPECIFICATION | ||||||||||||||||||||||
Characteristics | Discharge curves @ 25℃ (77 °F) | |||||||||||||||||||||
Capacity | 10 hour rate (0.9A) 5 hour rate (1.53A) 1hour rate (5.4A) | 9Ah 7.6Ah 5.4Ah |
| |||||||||||||||||||
Capacity affected by temperature | 40℃ (104 0F) 25℃ (77 0F) 0℃ (32 0F) | 102% 100% 85% | ||||||||||||||||||||
Internal Resistance | Full charged battery (25℃,77 0F) 10mΩ | |||||||||||||||||||||
Discharge at 72A for 5 seconds (-10℃) | ≥9.3V | |||||||||||||||||||||
Discharge at 72A for 90seconds (-10℃) | ≥6V | |||||||||||||||||||||
Constant Voltage Charge | Cycle | Initial Charging Current less than 2.7A Voltage 14.4~15.0V at 25℃ (77 0F ) Temperature Coefficient –5mV/℃ | ||||||||||||||||||||
Standby | No limit on Initial Charging Current Voltage 13.5~13.8V at 25℃ (77 0F ) Temperature Coefficient –3.3mV/℃ |
供方責任:
38AH(含38AH)以上蓄電池,質保期為三年,三年出現任何非人為質量問題,免費更換全新的同品牌同型號規格的蓄電池.非人為質量問題包括:運輸過程中造成的電池破損、鼓包、漏液、電池電壓范圍異常、接線端子變形等.
本公司還供應以下產品:
湯淺蓄電池、松下蓄電池、理士蓄電池、賽特蓄電池、圣陽蓄電池、雙登蓄電池、非凡蓄電池、科士達蓄電池、梅蘭日蘭蓄電池、三瑞蓄電池、大力神蓄電池、凱鷹蓄電池、南都蓄電池、光宇蓄電池、風帆蓄電池、臥龍燈塔蓄電池、德國陽光蓄電池、美國山特電源、APCUPS不間斷電源
專業的ups不間斷電源鉛酸免維護蓄電池供應商及服務商
質量是企業的生命,服務是企業的根本。
正如美國橄欖球明星湯姆·布雷迪曾經說過的那樣,“如果不想獲得勝利,就不要打球”。這個反映在布雷迪的TB12方法中,這是一個基于12條原則的整體生命周期,它構成了運動、訓練的充滿活力的方法。其前提是在事件發生前阻止發生,并采取明智的、戰略性的預防措施。雖然不需要實施這12個原則,但是它們的效果是累積的:能融入的越多,其結果就會越好。
雖然這種方法適用于培訓高級運動員,但數據中心有其自己的一套原則來確保數據中心的性能。稱之為DCM10方法,每個數據中心管理人員都應該使用10個基本步驟來評估他們當前的數據中心,并幫助轉換其功能。與TB12方法類似,雖然并非所有這些步驟都是制定成功策略所必需的,但應用更多的實踐將會帶來更高的性能。
為了實現和維持數據中心的性能,每個數據中心都應該遵循以下10個步驟:
1.利用混合環境
通過為企業的IT基礎設施混合使用各種解決方案,企業應該獲得更好的可視性和控制權,以訪問關鍵的洞察力。無論是內部部署,托管數據中心還是云計算,達到性能意味著創建靈活、可擴展、可持續和可靠的數據中心,以滿足當前和未來的業務需求。
2.優化電力和冷卻設施
大多數使用高密度服務器的企業正在產生大量的熱量,并且比傳統老式設備消耗更多的電力。隨著新技術的進步,如大數據和機器學習,這種功率和隨后的熱量增加只會增加。由于典型機架的功率密度范圍從5kW到40kW不等,數據中心管理人員需要制定新的程序和軟件,以獲得預測新發現的冷卻要求的實時見解。
3.開始思考綠色節能
除了監測電力和制冷之外,數據中心管理人員應評估“綠色”替代品以提高能源效率。通過使用風力發電或太陽能電池板等可再生資源,企業可以將其數據中心戰略轉變為包含環保實踐,并優化其現有數據中心基礎設施。
4.進行自動健康檢查
通過持續的分析、診斷和修復,數據中心管理人員可以定期進行健康管理檢查,以解決代價高昂的停機和中斷風險。通過持續監控數據異常情況或潛在威脅,企業可以通過規劃和解決系統內可能發生的任何問題來保護其設施,以幫助自動化業務流程。
5.采取積極主動的立場
除定期的健康檢查外,實時監控企業的數據中心還可讓工作人員做好zui壞的準備,并采取積極主動的態度應對任何不可預見的威脅,例如自然災害。這意味著要從數據中心的日常性能到制定災難恢復計劃等任何事情都有可能發生沖突。
6.平衡預算
如果沒有的數據中心設施和IT設備,組織可能會落后于直接影響其業務成功。由于IT預算中只有一部分于數據中心,數據中心管理人員必須首先保持功能、效率、空間之間成本的平衡,并且只實施與其數據中心的性能、可靠性和敏捷性直接相關的智能升級。
7.獲得高層管理人員的支持
企業的數據中心戰略中zui大的一個脫節就是沒有獲得高管的支持。為確保成功部署數據中心管理、整個團隊(IT,系統架構師和企業高管)必須共同協作,才能充分利用解決方案堆棧。