供貨周期 | 現貨 |
---|
我司所售的蓄電池保證是原廠原裝產品,,簽訂合同,并提供,
38AH以上出現非人為質量問題三年內免費更換同等型號的全新電池,請廣大客戶放心采購!-
參考價 | 面議 |
更新時間:2020-11-02 15:04:23瀏覽次數:822
聯系我們時請說明是化工儀器網上看到的信息,謝謝!
Energy蓄電池PL12-260 12V260AH詳細參數
Energy蓄電池PL12-260 12V260AH詳細參數
Battery Energy was established in 1987 and launched its revolutionary SuperGEL long life plate technology in the mid 1990's. Battery Energy manufactures a range of 20 year design life Gel batteries using its proprietary SuperGEL technology developed in collaboration with the CSIRO. Battery Energy's unique technology provides for a more robust and longer battery life than traditional manufacturing techniques especially in extreme climatic conditions, which makes it ideally suited to mission critical and safety applications in solar / RAPS, ecommunications, transport, power generation, military, railway and other applications.
UPS電源作為商場、超市、銀行、基站等大型公司的后備儲能電源有著重中之重的超然地位,除了有保護設備防斷電的的功能外,還肩負穩壓的作用。所以有了UPS不間斷電源才使我們的工作和日常生活井井有序。可是往往被忽視的也是重要的,人們認為UPS電源是免維護的,而不加以重視,從而減少了UPS的使用壽命。今天,雙飛科技給大家介紹一下如何維護UPS電源。
UPS電源的正常壽命,在室溫正常條件下且正常使用時,一般密封免維護鉛酸電池的浮充使用壽命3-5年。但是很多人為因素卻會使UPS電源的壽命大大縮短。可見UPS不間斷電源沒有合理維護會影響它的正常使用壽命,所以有幾個注意的小事項我們大家分享一下。
1、電池使用環境要求溫度在0度到40度之間,避免陽光直射并保持清潔。
2、正常時,電池每隔3-6個月充、放電一次,放電后標準機的充電時間應不少于10小時(這一項往往被人們忽視)。
3、UPS電源長期閑置不用,需做到每3-6月充電一次。
Battery Energy also produces a range of flooded lead acid batteries also with a 20 year design life for applications where flooded batteries are preferred to gel batteries, which incorporate the benefits of long life plate technology.
In 2004 Battery Energy sourced a supply partnership for a range of premium quality AGM batteries. With strong product performance and life this has been a major success. Battery Energy is 100% Australian owned company and has the financial backing of its shareholders who continue investing in the development the business.
澳大利亞BatteryEnergy(BE)電池成立于1987年,是的全密封免維護鉛酸蓄電池制造公司,專業研發和生產膠體和普通AGM鉛酸蓄電池數十年。本部生產廠位于澳大利亞悉尼Fairfield,2009年以專有的膠體電池技術在中國與廣州豐江實業有限公司采用中外合作方式設立了海外生產基地,產品100%外銷東南亞和歐美市場。2012年,BE電池收購了中國合作公司廣州豐江的100%股權,豐江成為BE電池在中國的全資制造子公司。目前,BatteryEnergy電池在中國市場主要銷售以下兩大系列產品:Energel系列膠體鉛酸蓄電池和Powerlyte系列普通AGM鉛酸蓄電池。
EnerGEL | Nominal Volts | Ah C/3聽 | Ah C/10 | Length | Width | Height | Weight |
4EG70 | 4 | 49聽 | 70 | 109 | 184 | 265 | 12 |
4EG100 | 4 | 73 | 98 | 109 | 184 | 265 | 15 |
6EG100 | 6 | 74 | 100 | 184 | 276 | 265 | 28 |
6EG130 | 6 | 97 | 132 | 184 | 276 | 265 | 33 |
6EG160 | 6 | 122 | 164 | 184 | 276 | 265 | 38 |
2EG200 | 2 | 146 | 196 | 187 | 197 | 265 | 18 |
2EG225 | 2 | 170 | 233 | 187 | 197 | 265 | 20 |
4EG225 | 4 | 170 | 229 | 184 | 276 | 265 | 33 |
4EG250 | 4 | 194 | 262 | 184 | 276 | 265 | 38 |
2EG300 | 2 | 219 | 297 | 184 | 197 | 265 | 23 |
2EG350 | 2 | 267 | 360 | 184 | 197 | 265 | 26 |
2EG400 | 2 | 316 | 429 | 184 | 276 | 265 | 33 |
2EG500 | 2 | 365 | 491 | 184 | 276 | 265 | 37 |
2EG550 | 2 | 413 | 556 | 184 | 276 | 265 | 40 |
2EG700 | 2 | 518 | 695 | 145 | 206 | 680 | 52 |
2EG800 | 2 | 592 | 794 | 145 | 206 | 680 | 58 |
2EG900 | 2 | 666 | 893 | 210 | 191 | 680 | 71 |
2EG1100 | 2 | 814 | 1092 | 210 | 191 | 680 | 76 |
2EG1300 | 2 | 962 | 1290 | 210 | 233 | 680 | 89 |
2EG1500 | 2 | 1110 | 1489 | 210 | 680 | 680 | 111 |
2EG1600 | 2 | 1184 | 1588 | 210 | 275 | 680 | 107 |
12EG100FTG | 12 | 76 | 103 | 394 | 125 | 286 | 42 |
12EG160FTG | 12 | 118 | 160 | 544 | 125 | 317 | 63 |
Energel系列包括6V&12V的6EG&12EG系列和2V&4V的2EG&4EG系列。
Powerlyte系列包括12V的普通型PL系列、12V的PLFT系列以及2V的固定型PXL和PXLT系列。
The material contained in this website is copyright. You may download, display, copy, print and reproduce material on this site in an unaltered form, for personal or non-commercial use or use within your organisation.
Requests and enquires relating to authorisation for reproduction of any information on this website can be made via the Contact Form found on the Contact Us page, directly to customer.service@batteryenergy.com.au or alternatively you may submit your request in writing to:
ACID As used in this website refers to sulphuric acid (H2SO4), the active component of the electrolyte, or a mixture of sulphuric acid and water.
ACTIVE MATERIAL The active portion of the battery plates; peroxide of lead on the positives and spongy metallic lead on the negatives.
AGM Absorptive Glass Mat or Starved electrolyte technology. This denoted a type of sealed lead acid battery.
ALLOY As used in battery construction is a homogeneous combination of lead and other suitable ingredients.
AMPERE The unit of measure of the rate of flow of electric current. One amp flowing at the pressure of one volt equals one watt.
AMPERE HOUR The product resulting from multiplication of amperes flowing by time of flow in hours, e.g., a battery supplying 10 amperes for 8 hours gives 80 ampere hours. See note under "Volt?' for more complete explanation of current flow.
BATTERY Two or more electrical cells electrically connected in series so that combination furnishes current as a unit.
BATTERY CHARGER See rectifier.
BATTERY TERMINALS The battery terminals are the means to access the stored electrical energy in the battery. There is a minimum of one positive and one negative terminal.
CAPACITY The number of ampere hours a battery can supply at a given rate of current flow after being fully charged, e.g., a battery may be capable of supplying 10 amperes of current for 8 hours before it is exhausted. Its capacity is 80 ampere hours at the 8 hours rate of current flow. It is necessary to state the. rate of flow, since same battery if discharged at 20 amperes would not last for 4 hours but for a shorter period, say 3 hours. Hence, its capacity at the 3 hour rate would be (3 x 2O = 60) ampere hours.
上一章節主要介紹了介紹了數字控制UPS電源的應用優勢體現在哪些方面。本章節主要介紹了基于DSP數字控制UPS電源的工作流程和組成結構,深入剖析了關鍵電路的結構功能,對數字化UPS電源應用具有重要現實指導意義。
一、DSP控制的UPS電源工作流程
DSP控制的數字式UPS電源的工作流程是:當市電正常情況下,輸入電壓、頻率在允許的范圍時,PFC部分對輸入進行功率因數校正,使得該系統的輸入功率因數為0.98左右,同時避免對電網產生污染,輸入的市電經PFC環節變換得到400V直流輸出電壓,為后面的逆變電路提供能量。同時DC/DC部分仍然在正常工作,只是由于電池電壓經過DC/DC電路變換得到360V輸出電壓,略小于市電經PFC變換得到的直流母線電壓,這樣通過二極管就將它和直流母線隔離,DC/DC部分空載運行,處于熱備用狀態。當市電不正常時,市電掉電或者輸入電壓、頻率不在允許的范圍時,市電經PFC得到直流母線電壓迅速降低,當低于360V時,二極管導通,使得直流母線電壓維持在360V,此時逆變器得到的能量是由電池電壓經由DC/DC電路變化得到的直流母線電壓。無論市電是否正常逆變部分均可以正常的工作。一般蓄電池可提供幾分鐘到幾十分鐘的后備供電時間,大容量的電池組的后備供電時間可以達幾個到幾十個小時,對于備有柴油發電機的用戶,可以在市電停電5~10秒之內把柴油發電機投入到UPS電源的輸入端,可以在長時間停電的情況下向用戶提供高質量的正弦波電源。經處理以后的市電同時還送給市電電壓/流相位測量電路,產生市電電壓信號和相位信號,供微處理器電壓/流測量和同步鎖相之用。這樣就實現了對負載的不間斷供電功能。
二、DSP控制的UPS電源組成結構
UPS電源要實現數字化控制化,那要用更多的模擬器件才能實現的控制功能和算法就可以通過DSP的軟件的編程來實現,所以整個UPS電源的結構就相比較用模擬器件的實現的UPS電源的整體結構要簡單得多。如圖1所示下面就是數字化的UPS電源的整體框圖。主要由輸入功率因數校正、逆變部分、DC/DC等組成。
圖1基于DSP控制的UPS電源原理框圖
三、DSP控制的UPS電源關鍵電路結構
(1)UPS電源的功率校正電路
輸入功率因數校正電路如圖2所示主要由功率管T5、電感L1、二極管D1、電容C1組成。它為輸入部分提供功率因數校正功能,并且提升電壓至400V。
圖2輸入功率因數校正電路圖
輸入功率因數校正因數電路的工作原理,UPS電源市電通過功率因數校正模塊,來進一步減少來自電網*,同時使整個UPS電源系統的功率因數和轉換效率得到提高。功率校正模塊是一個AC/DC變換器,它完成輸入的整流,同時控制輸入電流為正弦波,從而達到很高的輸入功率因數。功率因數校正部分還必須保持直流電壓恒定,不隨輸入的變化而改變。直流電壓又在逆變部分變換成幅值、頻率合適的交流電源。當UPS電源工作處在蓄電池方式時,該直流電源經過DC/DC變換隔離后得到逆變部分所需的直流電壓。
(2)正弦逆變電路結構
正弦逆變電路如圖3所示主要是由電容C1,功率管T1、T2、T3、T4組成的逆變橋,電感L2,電容C2等組成。PFC模塊的輸出經由逆變部分能夠產生負載所需的純正弦波交流電壓。
圖3正弦逆變器電路圖
數字UPS電源的正弦逆變器是時刻處于工作過程中,其工作原理是通過采樣電路對逆變電路輸出電壓和電流進行采樣,得到的采樣信號輸入到DSP,通過對采樣信號進行處理,依照一定的算法和程式來實現正弦逆變電路控制的功能。
(3)DC/DC電路結構
DC/DC電路的構成如圖4所示,主要是由高頻變壓器、功率管T6、T7,整流二極管D33、D34、D35、D36,電容C31等組成。該部分采用直流電壓環反饋控制,變換后的電壓通過二極管D6與PFC的輸出端相連。
圖4DC/DC電路的結構圖
由于電池電壓比較低,逆變器對直流電壓的利用率又不高,因此需要DC/DC電路來轉換電池的電壓。而DC/DC的電路結構有很多,但是各有優缺點,zui常用的就是推挽式直流變換電路這種電路的優點就是驅動電路簡單,輸出功率大。一般被功率要求比較高的負載選作直流變換電路。
(4)UPS電源其他結構功能
同時通過SCI和SPI來實現整臺UPS電源的監控程序,通過SCI口和微機進行通信,實現遠程監控是全數化UPS電源的重要結構功能。
其中一方面,在UPS電源運行時出現市電故障或停電時,UPS電源會利用上述通訊通道向由它供電的計算機網絡傳送因市電故障產生的報警信號。當長時間停電,而電池組的供電電壓要低于臨界放電電壓時,計算機網絡會在UPS電源發出自動關閉命令的驅動下,完成數據的保存和設備的保護。
而另一方面,提供一個友好的人機界面,可實時監視UPS電源的運行參數,方便用戶的參數修改,同時便于用戶查詢UPS電源運行的歷史記錄。還可在計算機網絡上對UPS電源進行定時的開機/自動關機操作。為實現上述控制功能,還可以提供RS-232和RS-485通信接口,用戶可根據實際情況任選一種。對于要求執行網絡管理功能的UPS電源,應配置有簡單的網絡管理協議(SNMP)適配器或適配卡。
隨著數字化技術的發展,DSP技術已被越來愈多UPS電源廠家應用于產品中。而DSP技術也被廣泛應用一方面提高了UPS電源產品輸出電壓的穩定性和純凈程度,另一方面也提高了UPS電源產品自身的可靠性。而IGBT技術和高頻技術的應用,除了大大提高了電源效率,降低了系統噪音和電源自身的電力損耗外,也大大提高了系統的可靠性。UPS電源的數字化并不是簡單的指在系統中應用了數字器件,如單片機及FPGA等,而是指整個系統的控制應用數字器件的計算能力和離散控制方法來完成。隨著數字處理硬件技術的發展,計算速度的提高,必然會促使UPS電源產品向數字化方向發展。
CASE The container in which the battery cells are housed.
CELL The battery unit, consisting of an element complete with electrolyte, in its jar with cover. Lead acid battery cells are nominally 2-volts. Two volts is the minimum nominal voltage for a lead acid cell.
CHARGE Passing direct current through a battery in the direction opposite to that of discharge, in order to put back the energy used on discharge.
CHARGE RATE The proper rate of current to use in charging a battery from an outside source. It is expressed in amperes and varies for different sized cells.
CORROSION The attack of metal parts by acid from the electrolyte; it is the result of lack of cleanliness.
COVER The cover forms a lid on each individual cell. It is usually tongue and groove flange for a more effective seal.
CYCLE One charge and discharge.