供貨周期 | 現貨 |
---|
我司所售的蓄電池保證是原廠原裝產品,,簽訂合同,并提供,
38AH以上出現非人為質量問題三年內免費更換同等型號的全新電池,請廣大客戶放心采購!-
參考價 | 面議 |
更新時間:2020-11-02 15:04:23瀏覽次數:354
聯系我們時請說明是化工儀器網上看到的信息,謝謝!
寶迪BUDDY鉛酸蓄電池6-GFM-7 12V7AH
寶迪BUDDY鉛酸蓄電池6-GFM-7 12V7AH
寶迪BUDDY鉛酸蓄電池6-GFM-7 12V7AH
網頁資源有限,電源解決方案,UPS電源具體型號報價,技術咨詢(說出您的負載、預計延遲時間,我們會有專門的工程師為您配置*的電源解決方案)
Bao di battery
A, product characteristics and the seal: the unique production technology and special structural design, guarantee the safety of the battery and sealing. Free maintenance: unique gas recombination system can produce gas recombination into water, the adsorption type fiber separator from work, in the life of electro-hydraulic without compensation. Low self-discharge: using corrosion resistance is made from good special lead calcium alloy plate grid, control the self-discharge in minimum, stored under room temperature 25 ℃, but don't have to add electricity within half a year. Using a wide temperature range: battery in - 10 ℃, 40 ℃ temperature range. Easy installation: according to the requirements of the user in the form of standing and lying put installation. Long life design: adopt ? corrosion resistant structure
近日,維諦(Vertiv,原艾默生網絡能源)技術有限公司主辦的“思無界•設享V來—2018設計院專家論壇”在北京隆重召開。論壇以“關鍵技術成就可靠與節能的*平衡”為主題,來自設計院的技術大咖及維諦(Vertiv)的產品技術專家,針對數據中心的發展趨勢,從技術應用、規劃設計以及供配電、熱管理關鍵系統的選擇等維度呈獻了多個精彩的技術報告,并分享了維諦(Vertiv)的科技創新成果及大量成功實踐。
一直以來供配電系統作為數據中心基礎設施主要組成部分,它的高可靠、高可用性、高節能性能高可維護性在數據中心行業備受關注,因此對于數據中心供配電技術的研究也從未中斷。當前圍繞數據中心供配電技術、產品、應用和整體解決方案也逐漸向標準化、系統化的方向發展,選擇綠色的、經濟的、高效的、可用性高的供配電系統已經成為數據中心建設和運維行業的共識。
中國科學院計算所高級工程師李成章
對此,中國科學院計算所高級工程師李成章在《數據中心供配電系統的可用性分級管理》的演講中,深入探討了高性價比的數據中心供配電解決方案追求的核心價值,并指出要根據數據中心的不同用戶對可靠性、效率、成本的不同業務需求來選擇的UPS產品及其對應的供配電系統的可用性級別和架構,從而獲得*的TCO。
誘發數據中心供配電系統故障的幾大因素
在造成數據中心癱瘓的原因中,以因供配電系統的產品選型和設計架構的”考慮欠妥”所誘發的電氣癱瘓的危害性zui大。相關的統計資料顯示,它存在如下幾種典型的故障隱患:(1)因UPS供電系統的產品或可用性級別的”選配欠妥”所誘發的故障占29%;
(2)因人為操作“失誤”所誘發的故障占24%(例:2017年5月,因托管機房的工程師對UPS供配系統的輸入開關執行”誤關斷”操作而致使某國外航空公司的幾乎所有的IT設備進入”宕機癱瘓”的事故);
(3)因未考慮到發電機帶電容性負載的帶載能力會“變弱“以及因階躍性負載的“負載突增量過大”等原因所誘發的發電機“自動關機”的故障占10%;
(4)因氣候及自然災害所誘發的故障占12%(例:2017年12月,國外某機場因電力電纜的火災所造成的長達十余小時的大面積停電事故)。
顯而易見,能否消除掉上述的、足以對供配電系統的安全運行造成“致命危害”的故障隱患是能否確保該數據中心機房能長期可靠地運行的關鍵所在,以便為在后期的機房的日常運維操作過程中,能夠及時地發現和規避這些風險、確保它能獲得令人滿意的可用性(99.99%∽99.999%)奠定下堅實的技術基礎。根據GB50174—2017數據中心設計規范的要求,對于負責向IT/網絡等關鍵設備供電的供配電系統而言,它所允許的瞬間供電中斷時間應小于10ms。
通過對近年來發生在數據中心供配電系統中的多起事故的分析發現:同工頻機UPS供配電系統相比,導致傳統高頻機UPS和模塊化UPS供配電系統的故障率增高的重要誘因是:因為它們的抗瞬態輸入過壓保護的能力“變差“所致。通過在用戶現場所捕捉到的輸入故障波形以及在所搭建的故障模擬平臺上所檢測到數據可見:因“輸入瞬態過壓”而致使傳統高頻機和模塊化UPS的典型故障類型有:因電池組異常放電所誘發的電池組使用壽命縮短;在UPS供配電系統的輸出端發生輸出閃斷或“被損環”的事故。其故障高發期是:
(a)當10KV高壓因故發生停電/閃斷事故時或位于這些UPS供電系統上游側的大容量ATS開關因故需執行切換操作的瞬間。在此期間,在UPS的輸入端出現“輸入瞬態過壓”故障的幾率很高;
(b)為降低生產成本和充分利用廉價電能(注:夜間谷期電價僅為白天峰期電價的1/3左右),高能耗企業可能會采用夜間生產、白天停工的生產管理體制。對于地處鄰近高能耗企業的數據中心而言,極易在高能耗企業“突然抽閘”的瞬間,在它的市電輸入電網上誘發出”瞬態輸入高壓”。在此條件下,易發生電池組異常放電故障,從而造成電池組使用壽命縮短,增加后期運維成本。
李成章在演講中以某數據中心的供配電系統故障為例,指出在該數據中心的運行中,因故遇到10KV高壓電網發生停電幾分鐘的電力事故,導致運行僅1年多的3*300KVA高頻UPS并機系統發生故障:UPS并機系統輸出“閃斷”,并長期停留在交流旁路上。與此同時,位于同一機房中的已運行十幾年的另外兩套3*800KVA工頻機UPS并機系統卻一直正常地運行著。由此不難看出:此次事故就是因傳統高頻機UPS抗“瞬態輸入過壓”的保護能力”變差”所誘發出的故障,給該數據中心所需的應持續穩定運行帶來負面影響。
寶迪電池一、產品特點 安全和密封:采用*的生產工藝和特殊的結構設計,保證電池使用的安全性和密封性。 免 維 護:*氣體再化合系統能將產生的氣體再化合成成水,吸附式下班纖維隔板,在壽命期 內無需補償電液。 自放電低:使用耐腐蝕性好的特殊鉛鈣合金制成的板柵,把自放電控制在zui小,室溫25℃下儲存,可半年之內不用補充電。 使用溫度范圍寬:電池可在-10℃—40℃的溫度范圍內使用。 安裝方便:可根據用戶的要求立放、臥放方式進行安裝。 長壽命設計:采用耐腐蝕結構的重型鉛鈣合金極板,保證了電池的浮充壽命二、應用范圍 適合電信、電力和UPS的使用。三、技術參數FM系列產品規格及技術參數 Specification & Technical Parameters of FM Battery Series
蓄電池應用領域與分類:
◆ 免維護無須補液; ● UPS不間斷電源;
◆ 內阻小,大電流放電性能好; ● 消防備用電源;
◆ 適應溫度廣; ● 安全防護報警系統;
◆ 自放電小; ● 應急照明系統;
◆ 使用壽命長; ● 電力,郵電通信系統;
◆ 荷電出廠,使用方便; ● 電子儀器儀表;
◆ 安全防爆; ● 電動工具,電動玩具;
◆ *配方,深放電恢復性能好; ● 便攜式電子設備;
◆ 無游離電解液,側倒仍能使用; ● 攝影器材;
◆ 產品通過CE,ROHS認證,所有電池 ● 太陽能、風能發電系統;
符合國家標準。 ● 巡邏自行車、紅綠警示燈等。
規格型號 | 標稱電壓(v) | 20HR額定容量(Ah) | 外形尺寸(mm) | 大約重量(Kg) | |||
長(L) | 寬(b) | 高(h) | 總高(H) | ||||
6-FM-7 | 12 | 7 | 151 | 65 | 94 | 100 | 2.2 |
6-FM-12 | 12 | 12 | 151 | 99 | 94 | 100 | 3.8 |
6-FM-15 | 12 | 15 | 151 | 121 | 94 | 100 | 4.5 |
6-FM-17 | 12 | 17 | 181 | 76 | 169 | 176 | 5.6 |
6-FM-24 | 12 | 24 | 165 | 125 | 175 | 180 | 9.2 |
6-FM-38 | 12 | 38 | 197 | 165 | 175 | 180 | 13.0 |
6-FM-50 | 12 | 50 | 260 | 133 | 205 | 205 | 17.0 |
6-FM-65 | 12 | 65 | 350 | 166 | 175 | 175 | 21.0 |
6-FM-90 | 12 | 90 | 328 | 172 | 213 | 242 | 29.5 |
6-FM-100 | 12 | 100 | 407 | 173 | 210 | 236 | 32.5 |
6-FM-150 | 12 | 150 | 484 | 171 | 242 | 242 | 48.5 |
6-FM-200 | 12 | 200 | 522 | 240 | 216 | 242 | 63 |
1.電池的*性和穩定性好,可并聯組數多達6組。1)*的極板設計縮短電流傳輸距離,降低內阻并使電池*性更好。2)從原料到成品,共經多次實驗和檢測。從原料,生產和檢測上保證電池的*性和穩定性。2.*的鉛膏配方,體積能量比更大,同等容量的電池,BUDDY的電池體積更小,可節省更大的空間。3.電池壽命長。1)提高極板厚度,使電池壽命提高。2)特別設計的ABS外殼和電池蓋,分子密度大,失水率小,使電池壽命提高。3)AGM設計,采用彈性強,微孔率高,吸液性能好,耐酸腐性好的超細玻璃棉。降低內阻,氣體復合率提高至99%以上,失水率小使電池壽命提高。4)擁有的閥壓高達12KP,zui大可能保持水分,提高電池使用壽命。5)閥的密封反應效率可達99.53%,保持水分,提高電池使用壽命。6)荷電保持能力高達99.7%,自放電小,提高電池存放時間和電池壽命。7)在正常使用中,電池閥不打開,以保持水分,提高電池使用壽命。4.電池的安全性好,因為1)采用特別設計的ABS塑料,與一般電池所采用的塑料相比,在熱封過程中,殼蓋黏結度更高,在使用中受環境溫度影響時,穩定性更好。2)采用*的熱封工藝,用高溫和高壓雙重熔封電池殼和電池蓋,防止漏液。3)生產中對每個電池采用高壓氣體和高壓電對電池進行密封實驗,確保電池密封性,保證每個電池的安全性。4)閥在過充狀態下打開時,經閥中堿性物質中和,使氣體無腐蝕性,進一步保證其安全性。5.強大的和良善的售后服務,確保客戶無使用后顧之憂。
1. The consistency and stability of the battery is good, and transmitte for up to 6 groups.
1) unique plate design to shorten the current transmission distance, reduce the internal resistance and make a battery consistency is better.
2) from the raw material to the finished product, after repeated experiments and testing. From the raw material, production and testing to guarantee the consistency and stability of the battery.
2. Lead advanced formulations, energy than a larger volume, the same capacity of the battery, BUDDY smaller batteries, can save more space.
3. Long battery life.
除此之外,李成章還舉例指出:隨著模塊化UPS內部所并聯的電源模塊的數量的不斷地增多(例:從傳統高頻塔式機的內置2-3個功率模塊增加到傳統模塊化UPS的內置10-20個電源模塊),它的“內部環流”必然會隨之而增大。由此所帶的新故障現象是:當用戶在因故對這種模塊化UPS執行停電維修操作之后(例:對機柜前面板上的“通風過濾罩”執行除塵清洗操作),再重新執行開機操作時,易發生UPS輸出閃斷或電源模塊”被損壞”的事故。
高性價比的高頻UPS產品應具備的運行特性
由于高頻UPS電源具有效率高、體積小、重量輕以及輸入功率因數達到0.99以上、輸入電流的諧波含量小于5%、對市電電網的污染小等優點而日益受到用戶的青睞。近年來,隨著UPS制備技術的進步和發展,為提高它的可維護性,高頻UPS逐步走向高智能模塊化,可通過增減UPS機柜內的小功率電源模塊數量的多少來滿足用戶對其功率輸出及可維護性的要求。這樣一來,它不僅具有很大的彈性,而且只要冗余允許還可以在線進行維護,實現”零維修時間”的操作功能。然而,對于部分高頻UPS的生產和開發企業來說,由于存在只重視追求更高的效率和更低的制備成本的傾向,不夠重視應采取必要的技術措施來消除傳統高頻機UPS和模塊化UPS因抗瞬態輸入過壓保護能力”變差”所帶來的故障率相對偏高的現象。
近年來,維諦(vertiv)公司遵循”不妥協的可靠性”的設計思念,通過在傳統高頻機UPS的整流器中增配”抗輸入過壓”保護部件的技術措施。這樣一來,在確保它能獲得”高效率”優點的前提下,還收到能大幅度地提高UPS可靠性以及將高頻機UPS的輸入功率因數(PF)從傳統的電容性調控到所期望的電感性。在此基礎上,開發出創新型的高性價比的UPS產品。
李成章指出,高性價比的高頻機UPS應該具有效率高(≧97%)、可靠性高(具有很強的抗輸入過壓保護能力,UPS單機內部環流=0)、輸入PF呈現電感性、高可維護性(例:易于對機內的”老化.濾波電容”執行現場的更換操作)等特點。只有具備這些特性,才能更好的保障數據中心的安全高效運行。在此背景下,不僅能為數據中心的供配電系統獲得令人滿意的高可用性奠定下堅實的技術基礎。而且,還有十分利于降低它的Capex和Opex。
數據中心供配電系統的”可用性分級管理”
確保數據中心安全無疑是整個信息系統安全運行的前提保障,對此,李成章表示,電癱瘓、熱癱瘓、網絡安全已然成為當今數據中心所面臨的三大故障隱患,如何避免及做好提前措施也成為備受關注的焦點。
同時,李成章基于全新的現場故障分析能力和實踐工作經驗,重點闡釋了供配電系統的”分級可用性”的設計與規劃。在對金融、交通,BAT及教育、商業等具有代表性用戶的業務特點、允許業務中斷的容忍度、IT系統及空調系統對供電系統的可用性的不同級別需求、IT/網絡的機柜功率密度的高低對MDC(微模塊)的設計架構的影響等進行全面分析后,李成章指出,采用“可用性分級管理”的設計理念的zui終目標是:在充分滿足用戶的不同業務需求的前提下,制定和選用具有TCOzui低運行特性的供配電系統的設計方案。
為進一步闡釋供配電系統分級可用性理念的重要意義,李成章以金融用戶和BAT用戶的供配電系統需求為例進行了說明。他表示,金融行業(集中處理)與BAT行業(分布式處理)對數據處理、存儲和分享性數據傳送的要求具有很大差異,前者要求數據應具有*的完整性、*性和高時效性。為此,其供配電系統的建設標準應采用帶物理隔離運行特性的*標準。李成章同時指出,即使在金融行業用戶中,由于總行、省市分行及縣級支行等機構級別的不同,其供配電系統的可用性級別也應不相同,在建設上也有所區別。
1) improve the plate thickness, improve the battery life.
2) the special design of the ABS shell and the battery cover, molecular density is big, small water loss rate, improve the battery life.
3) AGM design, the use of strong elasticity, high micropore rate, fluid absorption performance is good, good acid resistance superfine glass wool. Reduce the internal resistance and gas ?