亚洲中文久久精品无码WW16,亚洲国产精品久久久久爰色欲,人人妻人人澡人人爽欧美一区九九,亚洲码欧美码一区二区三区

| 注冊| 產品展廳| 收藏該商鋪

行業產品

13224517959
當前位置:
上海希言科學儀器有限公司>>美國戴安Dionex>> 077974美國戴安Dionex Acclaim Carbonyl LC Column 液相色譜柱

美國戴安Dionex Acclaim Carbonyl LC Column 液相色譜柱

返回列表頁
  • 美國戴安Dionex Acclaim Carbonyl LC Column 液相色譜柱
收藏
舉報
參考價 面議
具體成交價以合同協議為準
  • 型號 077974
  • 品牌
  • 廠商性質 代理商
  • 所在地 上海
在線詢價 收藏產品 加入對比 查看聯系電話

更新時間:2017/10/24 21:02:41瀏覽次數:2628

聯系我們時請說明是化工儀器網上看到的信息,謝謝!

同類優質產品

更多產品

產品簡介

戴安公司生產的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術優勢和方法已廣泛地應用于各個領域,其*達80%。與離子色譜相關的文章有90%均出自戴安公司生產的離子色譜儀。   
戴安公司的快速溶劑萃取儀15分鐘之內僅用15毫升溶劑既可完成對10g樣品的萃取,該技術已在環境、藥物、食品和聚合物工業等領域得到廣泛應用。

詳細介紹

美國戴安Dionex Acclaim Carbonyl LC Column 液相色譜柱

Acclaim Carbonyl LC Column 

High Resolution HPLC of Aldehyde and Ketone Contaminants

The Thermo Scientific Acclaim* Carbonyl C18 HPLC columns are designed specifically for superior resolution and high-throughput separation for DNPH derivatives of aldehydes and ketones regulated by the U.S. Environmental Protection Agency (EPA) in methods such as EPA 554, EPA 8315, EPA 1667, EPA TO-11, and by the California Environmental Protection Agency Air Resources Board in method CARB 1004.

  • High efficiency for UHPLC performance
  • Rugged columns with good lot-to-lot reproducibility
  • Proven robust methods

Carbonyl compounds, including low molecular weight aldehydes and ketones, cause environmental and health concerns. Because of their highly volatile and reactive nature, carbonyl compounds are often converted to the dinitrophenylhydrazine (DNPH) derivatives prior to analysis. The Acclaim Carbonyl C18 columns are high-performance reversed-phase columns specifically designed for high throughput and baseline separation of thirteen DNPH derivatives of aldehydes and ketones regulated by CARB Method 1004. In addition, the same chromatographic method can be applied directly to other regulatory methods such as EPA 554, EPA 8315, and EPA TO-11.

The columns are available in three particle sizes:  2.2, 3 and 5µm. Smaller particle sizes provide high peak efficiency for fast analysis. Small internal diameter (i.d.) columns (e.g., 2.1 and 3.0 mm) consume less solvents and produce less chemical waste. For high-throughput application, the 2.1 × 100 mm column format combined with high linear velocity should be considered. When high resolution power is desired, a longer column (2.1 × 150 mm) can be used at an optimal linear velocity to achieve even better resolution.

技術參數:

Acclaim Carbonyl C18 Column Specifications
Column chemistryProprietary alkyl group
Operating pressure limit (recommended)

800 bar for 2.1 x 150mm; 2.2µm

600 bar for 2.1 x 150mm; 3.0 µm

600 bar for 2.1 x 100mm

700 bar for 3.0 x 100mm

600 bar for 3.0 x 150mm

800 bar for 3.0 x 250mm

Operating pH range (recommended)2.5–7.5
Operating flow rate range (recommended)0.4–1.4  mL/min for 3.0 mm i.d. formats
0.25–0.75  mL/min for 2.1 mm i.d. formats
Operating temperature (recommended)25 -35 °C

訂購信息:

Analytical Columns
Acclaim Carbonyl RSLC Analytical,2.2µm (2.1 x 100mm)077972
Acclaim Carbonyl RSLC Analytical,2.2µm (2.1 x 150mm)077973
Acclaim Carbonyl RSLC Analytical,2.2µm (3.0 x 100mm)077974
Acclaim Carbonyl C18 Column 3µm Analytical (2.1 x 150 mm)079011
Acclaim Carbonyl C18 Column 3µm Analytical (3.0 x 150 mm)079010
Acclaim Carbonyl C18 Column 3µm Analytical (3.0 x 250 mm079009
Acclaim Carbonyl C18 Column 5µm Analytical (4.6 x 150 mm)079008

Guard Columns
Acclaim Carbonyl C18 Column 5µm Guard (2.1 x 10 mm), 2/pk079012
Acclaim Carbonyl C18 Column 5µm Guard (3.0 x 10 mm) , 2/pk079013
Acclaim Carbonyl C18 Column 5µm Guard (4.6 x 10 mm), 2/pk079014

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~

對比框

產品對比 產品對比 二維碼 意見反饋 在線交流
在線留言