亚洲中文久久精品无码WW16,亚洲国产精品久久久久爰色欲,人人妻人人澡人人爽欧美一区九九,亚洲码欧美码一区二区三区

北京榮興光恒科技有限公司
中級會員 | 第13年

13811719035

當前位置:北京榮興光恒科技有限公司>>尼康顯微鏡>>SMZ18>> SMZ18北京尼康SMZ18立體顯微鏡

北京尼康SMZ18立體顯微鏡

參  考  價面議
具體成交價以合同協議為準

產品型號SMZ18

品       牌Nikon/日本尼康

廠商性質經銷商

所  在  地北京市

更新時間:2017-12-12 08:54:51瀏覽次數:2334次

聯系我時,請告知來自 化工儀器網
同類優質產品更多>
新品尼康SMZ18立體顯微鏡
SMZ18
Manual zoom model providing advanced optical performance and incredibly bright fluorescence at an economical cost

新品尼康SMZ18立體顯微鏡

新品尼康SMZ18立體顯微鏡

Nikon has developed an all-new stereo microscope that features a large zoom ratio of 25:1, high resolution and exceptional fluorescence transmission capability to respond to increasing demand for imaging systems that span spatial scales from single cells to whole organisms.

  • World's largest zoom range and highest resolution in the SMZ series
  • Bright and high contrast fluorescent images
  • Automation and digital imaging
  • Easy to use


SMZ25

Motorized zoom model with the highest zoom ratio and resolution in the SMZ series

 

 

 


SMZ18

Manual zoom model providing advanced optical performance and incredibly bright fluorescence at an economical cost

 

 

 

 SMZ25SMZ18
TypeMotorized zoomManual zoom
Zooming observationBF/DF/FL/Simple polarizingBF/DF/FL/Simple polarizing
Zoom ratio25:118:1
Magnification range0.63x - 15.75x0.75x - 13.5x
Maximum magnification315x*1270x*1
Maximum FOVø70mm*2ø59mm*2
Maximum NA of objective0.312*30.3*3
  • *1Using SHR Plan Apo 2x/C-W 10xB
    • *2Using SHR Plan Apo 0.5x/C-W 10xB
      • *3Using SHR Plan Apo 2x

      Back to top

       

       

       

      World's largest zoom range and highest resolution in the SMZ series

      Dynamic zoom ratio of 25:1SMZ25

      An innovative optical system known as Perfect Zoom System provides the world's first zoom ratio of 25:1 (zoom range: 0.63x - 15.75x). Even with a 1x objective lens, the SMZ25 captures the entire 35mm dish and simultaneously delivers microscopic details.


      Arthromacra sp.
      (Using SHR Plan Apo 1x with SMZ25)
      Image courtesy of Japan Insect Association

      Offers the highest zoom ratio thanks to Nikon's Perfect Zoom System

      A breakthrough in stereoscope design, Perfect Zoom System dynamically change the distance between the two optical axes as the zoom factor is changed. This change in optical axis distance enables maximization of light entry into the optical system at every magnification. The result is an uncompromised, large zoom range, high resolution in both eye paths, and minimal aberrations over the entire zoom-range. Furthermore, this breakthrough in optical design enables all of these desirable features be housed in a compact zoom body, resulting in an ergonomic instrument design.

       

       

       

      Superior resolution never before seen on a stereomicroscope


      SHR Plan Apo series

      Nikon's newly developed objective lens series, the SHR Plan Apo series, offers a high resolution of 1100LP/mm (Observed value, using SHR Plan Apo 2x at maximum zoom). The new SHR Plan Apo series of lenses deliver brilliant images with true-to-life colors.

       

       

       

      Comparison of resolution and color aberration by resolution chart


      SMZ25

       

       

       


      Conventional model

       

       

       

       

       

       

       

       

       

      Auto Link Zoom (ALZ) supports seamless viewing at different scalesSMZ25

      ALZ automatically adjusts the zoom factor to maintain the same field of view when switching objective lenses. This function enables seamless switching between whole organism imaging at low magnifications and detailed imaging at high magnifications.

      Back to top

       

       

       

      Bright and high contrast fluorescent imagesSMZ25SMZ18

      Enhanced brightness and uniform illumination in low magnification range

      The SMZ25 series is the first stereo microscope in the world to use a fly-eye lens on an epi-fluorescence attachment. This innovative design ensures bright and uniform illumination even at low magnifications, resulting in uncompromised uniformity in brightness across a large field of view.

       

       

       

      Improved S/N ratio and crystal clear fluorescent images thanks to an improved optical system

      Nikon's newly developed optical system offers a drastic improvement in S/N ratio even at high magnifications. This improved S/N ratio makes it possible to capture cell division, which is difficult using conventional stereo microscopes, and samples with low excitation light.

      Zoom body with significant improvements in optical performance

      Nikon has succeeded in improving the signal and reducing noise in fluorescent images by using a short wavelength, high transmission lens. Combined with an innovative epi-fluorescence attachment, the SMZ18/25 is better able to detect excitation light than conventional fluorescent stereo microscopes.

       

       

       

      Sample images

      Industrial

       

       

       

      Bioscience


      Single fluorescent neurons can be visualized in live C. elegans
      Fluorescence and OCC images of a live C. elegans expressing GFP- and RFP-neurons
      (using SHR Plan Apo 2x at zoom magnification of 3x with SMZ25)
      Image courtesy of Julie C. Canman, Ph.D., Columbia University

       

       

       

      Back to top

       

       

       

      Automation and digital imaging

      A wide range of digital imaging capabilities with the Digital Sight series and NIS-Elements imaging software

      Easily obtain the information you need, such as Z drive position, zoom factor, objective lens, filter cube, and LED DIA brightness by using the Digital Sight series and NIS-Elements or Digital Sight series DS-L3 together with the microscope.

      Imaging Software NIS-Elements

      One software for all systems: NIS-Elements which is Nikon's flagship, cross-platform imaging software can now be used with Nikon's latest stereomicroscope systems SMZ25 and SMZ18. NIS-Elements enables a wide range of advanced digital imaging capabilities, easily from a PC.

      Multichannel (multicolor)

      Multiple fluorescent channels can be captured in conjunction with other imaging methods such as OCC or brightfield.

      Individual cells resolved in a live drosophila embryo expressing GFP and mCherry
      (Using SHR Plan Apo 2x at zoom magnification of 8x with SMZ25)
      Image courtesy of Max V. Staller, Ph.D., Clarissa Scholes, and Angela DePace, Ph.D., Harvard Medical School

      Time lapse

      Easily setup a time-lapse imaging experiment with NIS-Elements.


      (Using SHR Plan Apo 2x at zoom magnification of 9x with SMZ25 and camera head DS-Qi1)
      Image courtesy of Joe Fetcho, Ph.D., Cornell University

      Calcium-imaging: Time-lapse imaging of GCaMP expressing neurons inside a live zebrafish shows individual neurons firing at different times (arrowheads). The last time-frame shows a whole cluster of neurons firing (asterisk).

       

       

       

      Extended depth of focus (EDF)

      Capture multiple high resolution images at different focal depths to create a single extended depth of focus image or quasi-3D image.

      Select the in-focus area (white square) and produces one all-in-focus image
      Zebrafish embryo
      (Using SHR Plan Apo 2x at zoom magnification of 3.4x with SMZ25)
      Image courtesy of Hisaya Kakinuma, Ph.D., Laboratory for Developmental Gene Regulation, Developmental Brain Science Group, RIKEN Brain Science Institute

       

       

       

      Digital Sight Series DS-L3

      DS-L3 is an easy-to-use high-definition, large touch-panel monitor that can be used to quickly capture images without a PC or monitor. The scale bar automatically adjusts to accommodate changes in magnification. Optimal imaging parameters for each sample type and observation method can easily be set using the icons.

       

       

       

      Detected observation condition/available control
      : Detection and control of observation condition possible
      : Detection of observation condition possible
       SMZ25SMZ18
      • Motorized focus unit
        • Motorized epi-fluorescence light set (control box A)
      • Manual focus unit
        • Manual epi-fluorescence light set (relay box and control box B)
      DS-L3NIS-ElementsDS-L3NIS-Elements
      Zoom magnification
      Focusing
      Objective (with nosepiece)
      Diascopic LED illumination stand (ON/OFF, light intensity control)
      Fluorescence illuminator (light intensity control)
      Filter cube changeover

      For other combination, please confirm Nikon.

      • *With NIS-Elements F (Free package), functions above are not available. Use NIS-Elets D/Br/Ar.
      •  
                                      •  
                                      •  
                                                                      •  
                                                                      •  
                                                                                                      •  

                                                                                                  會員登錄

                                                                                                  ×

                                                                                                  請輸入賬號

                                                                                                  請輸入密碼

                                                                                                  =

                                                                                                  請輸驗證碼

                                                                                                  收藏該商鋪

                                                                                                  X
                                                                                                  該信息已收藏!
                                                                                                  標簽:
                                                                                                  保存成功

                                                                                                  (空格分隔,最多3個,單個標簽最多10個字符)

                                                                                                  常用:

                                                                                                  提示

                                                                                                  X
                                                                                                  您的留言已提交成功!我們將在第一時間回復您~
                                                                                                  撥打電話