詳細介紹
FESTO費斯托比例減壓閥工作原理:導閥的開啟都是利用頂部的調節螺栓順時針方向擰動,使彈簧縮產生的彈力,使導閥膜片向下凹陷,作用在導閥連桿上的力,使之向下位移打開導閥。當導閥開啟后,上游進汽管段A腔的蒸汽通過α通道(供汽調節通道),經過導閥進入導閥環形汽腔,由β通道直接送到下面的活塞汽缸上腔。在A腔蒸汽不斷的供給下,壓力持續升高,推動活塞下行打開主閥,這時蒸汽*從A腔流至B腔。當下游出口管段B腔負荷滿足的情況下,余多的蒸汽又使B腔內的壓力不斷升高。不斷升高的壓力通過γ通道(壓力感應通道)反饋到導閥膜片下腔,使導閥膜片向上突起,克服了上部調節彈簧的壓力,導閥被關小或關閉。從而,關小或關閉來自上游α通道的蒸汽源。當活塞汽缸上腔壓力下降時,在下面復位彈簧的作用下,主閥被關小或關閉,這時B腔內的壓力開始下降,這樣周而復始達到調壓的目的。
FESTO費斯托比例減壓閥MPPE系列連接尺寸 G1/8, G1/4, G1/2
流量 0 ... 8,000 l/min
減壓閥
可連接外部的實際值傳感器
設定值模塊作為附件獲得.
德國FESTO FESTO比例閥 比例閥 費斯托比例閥 進口電磁閥 費斯托電磁閥型號 FESTO比例閥型號:MPPE-3-1/4- -B
MPPE-3-1/2- -B
MPPES-3-1/2-10-010
MPPES-3-1/2-10-420
MPPES-3-1/2-2-010
MPPES-3-1/2-2-420
MPPES-3-1/2-6-010
MPPES-3-1/2-6-420
MPPES-3-1/2-PU-PO-010
MPPES-3-1/4-10-010
MPPES-3-1/4-10-420
MPPES-3-1/4-2-010
MPPES-3-1/4-2-420
MPPES-3-1/4-6-010
MPPES-3-1/4-6-420
MPPES-3-1/4-PU-PO-010
MPPES-3-1/8-PU-PO-010
MPPES-3-1/8-10-010
MPPES-3-1/8-10-420 FESTO比例閥 FESTO比例閥
MPPES-3-1/8-2-010
MPPES-3-1/8-2-420
MPPES-3-1/8-6-010
MPPES-3-1/8-6-420
MPPES-3-1/2-PU-PO-420
MPPES-3-1/4-PU-PO-420
MPPES-3-1/8-PU-PO-420
MPYE-5-1/8-LF-010-B
MPYE-5-1/8-HF-010-B
MPYE-5-1/4-010-B
MPYE-5-3/8-010-B
MPYE-5-M5-010-B
MPYE-5-1/8-LF-420-B
MPYE-5-1/8-HF-420-B
MPYE-5-1/4-420-B
MPYE-5-3/8-420-B
MPYE-5-M5-420-B
FESTO費斯托比例調壓閥 MPPE-3-1/4-6-010-B - 161167 技術參數: 特性 特性
額定直徑, 加壓 7 mm
額定直徑, 排氣 7 mm
驅動類型 電氣的
密封原則 軟性
裝配位置 任何
設計結構 先導控制的活塞式減壓閥
短路強度 對于所有的電接口
安全操作指導 MPPE-B安全位置:如果電源電纜斷裂,輸出壓力保持未調節狀態
極性容錯保護 對于所有的電接口
閥功能 3位常閉比例減壓閥
壓力控制范圍 0 - 6 bar
輸入壓力 1 7 - 8 bar
zui大壓力遲滯 0,04 bar
切換時間,關閉 260 ms
切換時間,打開 150 ms
工作電壓范圍 DC 18 - 30 V
參考電壓 10 V
殘余紋波 10 %
設定值/實際值 電壓類型0 - 10 V
工作介質 過濾壓縮空氣,過濾精度 40 祄
中性氣體
防火等級符合 UL 94 HB
CE 符號 (參見符合的標準) 根據 EU-EMV 指導原則
耐腐蝕等級 CRC 2
介質溫度 0 - 60 °C
防護等級 IP65
環境溫度 0 - 50 °C
產品重量 920 g
電連接 8針
M16x0,75
插頭
符合DIN 45326
圓形設計
安裝類型 帶通孔
氣動連接, 氣口 1 G1/4
氣動連接, 氣口 2 G1/4
氣動連接, 氣口 3 G1/4
外殼的材料信息 鍛造鋁合金
隔膜的材料信息 NBR
德國FESTO FESTO比例閥 比例閥 費斯托比例閥 進口電磁閥 費斯托電磁閥型號 FESTO比例閥型號 161160 壓力比例閥 MPPE-3-1/8-1-010-B
161161 壓力比例閥 MPPE-3-1/8-6-010-B
161162 壓力比例閥 MPPE-3-1/8-10-010-B
161163 壓力比例閥 MPPE-3-1/8-1-420-B
161164 壓力比例閥 MPPE-3-1/8-6-420-B
161165 壓力比例閥 MPPE-3-1/8-10-420-B
161166 壓力比例閥 MPPE-3-1/4-1-010-B
161167 壓力比例閥 MPPE-3-1/4-6-010-B
161168 壓力比例閥 MPPE-3-1/4-10-010-B
161169 壓力比例閥 MPPE-3-1/4-1-420-B
161170 壓力比例閥 MPPE-3-1/4-6-420-B
161171 壓力比例閥 MPPE-3-1/4-10-420-B
161172 壓力比例閥 MPPE-3-1/2-1-010-B
161173 壓力比例閥 MPPE-3-1/2-6-010-B
161174 壓力比例閥 MPPE-3-1/2-10-010-B
161175 壓力比例閥 MPPE-3-1/2-1-420-B
161176 壓力比例閥 MPPE-3-1/2-6-420-B
161177 壓力比例閥 MPPE-3-1/2-10-420-B
161282 雙作用扁平抗扭 DZF-40-80-A-P-A
161283 雙作用扁平抗扭 DZF-40-100-A-P-A
161284 雙作用扁平抗扭 DZF-40-125-A-P-A
161285 雙作用扁平抗扭 DZF-40-160-A-P-A
161286 雙作用扁平抗扭 DZF-40-200-A-P-A
161287 雙作用扁平抗扭?DZF-40-250-A-P-A
187326 壓力比例閥 MPPES-3-1/2-10-010
187327 壓力比例閥 MPPES-3-1/2-10-420
187328 壓力比例閥 MPPES-3-1/2-2-010
187329 壓力比例閥 MPPES-3-1/2-2-420
187330 壓力比例閥 MPPES-3-1/2-6-010
187331 壓力比例閥 MPPES-3-1/2-6-420
187332 壓力比例閥 MPPES-3-1/2-PU-PO-010
187333 壓力比例閥 MPPES-3-1/4-10-010
187334 壓力比例閥 MPPES-3-1/4-10-420
187335 壓力比例閥 MPPES-3-1/4-2-010
187336 壓力比例閥 MPPES-3-1/4-2-420
187337 壓力比例閥 MPPES-3-1/4-6-010
187338 壓力比例閥 MPPES-3-1/4-6-420
187339 壓力比例閥 MPPES-3-1/4-PU-PO-010
187347 壓力比例閥 MPPES-3-1/8-PU-PO-010
187348 壓力比例閥 MPPES-3-1/8-10-010
187349 壓力比例閥 MPPES-3-1/8-10-420
187350 壓力比例閥 MPPES-3-1/8-2-010
187351 壓力比例閥 MPPES-3-1/8-2-420
187352 壓力比例閥 MPPES-3-1/8-6-010
德國FESTO FESTO比例閥 比例閥 費斯托比例閥 進口電磁閥 費斯托電磁閥型號 FESTO比例閥型號 FESTO費斯托比例減壓閥安裝說明
1、在比例式減壓閥安裝前應將管道沖洗干凈并在閥前加裝 Y 型過濾器由于管道內細小的雜物都將會導致減壓閥關閉不嚴從而引起滲漏而失效導致閥后管網靜壓超高。 過濾器應設置在總管上并去掉堵頭引出裝有閥門的排水管至污水池以便及時排污。
2、比例式減壓閥前后必須設置閘閥或蝶閥以便檢修時切斷水源。
3、比例式減壓閥宜垂直安裝。 其安裝說明書上說可垂直安裝也可水平安裝但當水平安裝時由于重力作用會造成下部的偏心磨損因此宜垂直安裝并應按閥體上所示箭頭方向安裝。 江銀大廈消火栓給水自動噴淋系統比例式減壓閥均采用垂直安裝減壓效果明顯功能正常。
4、在高層建筑消防給水中為保證供水的不間斷性減壓閥組宜設計為兩組同徑并聯其中一組工作一組備用。 且應與前后管徑相同以便檢修更換時不影響供水。
5、消防給水系統中比例式減壓閥不宜設置旁通管。 在江銀大廈消火栓系統減壓閥施工中初期安裝了旁通管在使用約一年半后季檢時發現閥后壓力表與閥前壓力表數值相同打開試驗閥放水試驗測試壓力則又顯示正常而后檢查時發現是由于設于旁通管上的閥門膠襯老化導致滲漏而出現靜壓失常動、壓正常的現象。 所以為保證消防給水系統的供水可靠性,本人認為不應設置旁通管。
6、在比例式減壓閥前后宜裝設壓力表可直接用于觀察減壓閥前后壓力的變化監察減壓閥的減壓效果和工作情況。
7、在高層建筑消火栓系統的比例式減壓閥后一般宜設置可曲撓橡膠接頭。 一方面為便于減壓閥安裝拆卸同時亦可起到伸縮節作用。