亚洲中文久久精品无码WW16,亚洲国产精品久久久久爰色欲,人人妻人人澡人人爽欧美一区九九,亚洲码欧美码一区二区三区

自然基因科技有限公司

多肽合成儀,熒光原位雜交,耶拿攝像頭,微核分析

化工儀器網(wǎng)收藏該商鋪

17

聯(lián)系電話

13701376913

     小標 您所在位置:首頁 > 供求商機> LEJA計數(shù)板 20-20 MICRON - 2 CHAMBERS
產(chǎn)品搜索

請輸入產(chǎn)品關(guān)鍵字:

聯(lián)系方式
地址:北京海淀區(qū)芙蓉里南街6號白環(huán)公寓1905室
郵編:100080
聯(lián)系人:馬強
電話:010-51650520
傳真:010-51650521
手機:13701376913
留言:發(fā)送留言
網(wǎng)址:www.naturegene.cn
商鋪:http://www.weixunsd.com/st94165/
供求商機

LEJA計數(shù)板 20-20 MICRON - 2 CHAMBERS

  • 發(fā)布日期:
  • 有效日期:
  • 所 在 地:
  • 產(chǎn)  地:
  • 已獲點擊:

  • 2024年10月11日
  • 2025年4月11日
  • 美國自然基因有限公司
  • 115次

【產(chǎn)品簡介】

20 MICRON - 2 CHAMBERS


【詳細說明】

A number is not always what it seems to be. What is the confidence interval? How accurate and precise is the assessment? The Leja 2-chamber slide is perfect for a cost effective replacement of the Improved Neubauer in semen analysis according the WHO manual. It allows the assessment of viscosity (in centiPoise, cP), motility and concentration with one slide. The same accuracy as the Improved Neubauer is achieved, but with higher precision, without additional dilutions. It saves 30 minutes of a technician"s time. One slide allows the WHO method of decision making in accepting or rejecting the concentration figure. The limits of quantification will be 5.000/ml - 200?06/ml (manual assessments). This slide can be used for the viscosity assessment.
20 MICRON - 2 CHAMBERS的詳細介紹

20 MICRON - 2 CHAMBERS.

A number is not always what it seems to be. What is the confidence interval? How accurate and precise is the assessment? The Leja 2-chamber slide is perfect for a cost effective replacement of the Improved Neubauer in semen analysis according the WHO manual. It allows the assessment of viscosity (in centiPoise, cP), motility and concentration with one slide.
The same accuracy as the Improved Neubauer is achieved, but with higher precision, without additional dilutions. It saves 30 minutes of a technician"s time. One slide allows the WHO method of decision making in accepting or rejecting the concentration figure. The limits of quantification will be 5.000/ml - 200•106/ml (manual assessments).
This slide can be used for the viscosity assessment.
To get a more precise concentration figure, the initial concentration figure needs to be corrected for the Segre Silberberg effect (a natural occurrence when using a capillary filled chamber; this effect causes a constant underestimation of the concentration). Only Leja slides are calibrated and a manual gives you the correction figures.
This slide works well in any CASA. In one assessment, you will be able to perform concentration and motility, and, if needed, a morphological assay. Leja slides are well equipped for manual counting. A manual is available through your local Leja distributor or here.

Please download a PDF brochure here [409 KB].
Catalogue numbers: SC-20-01-02-B (laminar)and SC-20-01-C (curved)

    
留言框
感興趣的產(chǎn)品: *
留言內(nèi)容:
您的姓名: *
您的單位:
聯(lián)系電話: *
微信:
常用郵箱:
詳細地址:
省份: *
驗證碼: * =   請輸入計算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
      
| 商鋪首頁 | 公司檔案 | 產(chǎn)品展示 | 供應(yīng)信息 | 公司動態(tài) | 詢價留言 | 聯(lián)系我們 | 會員管理 |
化工儀器網(wǎng) 設(shè)計制作,未經(jīng)允許翻錄必究.Copyright(C) http://www.weixunsd.com, All rights reserved.
以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責(zé),化工儀器網(wǎng)對此不承擔(dān)任何保證責(zé)任。
溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。
二維碼

掃一掃訪問手機站