供貨周期 | 現貨 | 規格 | 12V2.3AH |
---|---|---|---|
貨號 | 198 | 主要用途 | UPS電源,直流屏 |
韓國ATLASBX蓄電池KB2.3-12 12V2.3AH后備
參考價 | 面議 |
更新時間:2020-11-02 15:02:07瀏覽次數:331
聯系我們時請說明是化工儀器網上看到的信息,謝謝!
韓國ATLASBX蓄電池KB2.3-12 12V2.3AH后備
韓國ATLASBX蓄電池KB2.3-12 12V2.3AH后備
????BX? ???? ????? ?? ???? ????? ??????? ??? ???? ?? ??? ??? ??? ???????.????BX? 1944? ?? ?? 70? ? ?? ?? ??? ?? ??? ?? ??? ??? ???? ???????.
1982? ?? ?? ???(MF) ???? ??? ? 2013? ???????(UHPB), ??????? (Idle Stop & Go)? AGM ??? ?? ???? ? ?? ??? ??? ???? ????? ?? ?? ??? ?? ???? ??? ????? ???? ????.
??, ??? ?? ???? ?? 2014? ????? ???? ? 1,300? ?? ??? ?? ??? ??? ??? ??? ??? ??????, ??? ??? ?? ??? ???? ????? ???(Proactive Leadership) ????? ???? ????.
????BX? ‘??? ???? Leading Global Energy Company’? ???, ‘??? ???? ?? ????, ??? ??? ???? ??, ?? ?? ??? ???’? ??? ??? ??? ???? ????. ???? ? ?? ??? ???? ???? ????? ?? ??? ???, ?? ??? ??? ??? ?? ? ???? ??? ?????.
??? ???
Silver ???? ? ?? ???? ??? ??? ????? ???????
?? ? AGM ?? ?? ? ?? ? ???? ??
?????? ???? AGM ???? ????? ????? ??? ????? ?????
??? ?????
??? ???? ??? ???? ????? ?? ???? ?? ?????
???? ??? ???? ???? ???? ?? ? ??? ??? ?????
?? ?? ?? ?? ?? ?? ? ?? ?? ?? ???? ? ?? ??? ???????
Cu-Zn(????) ????? ???? ?????? ?? ????? ?????
?? ??? ?????
?? ? ? ?? ????? ???? ?? ? ?? ?? ??? ?? ????
????? ?? ?? ? ??? ???? Flame Arrestor? ???????
3? ?? ? ?? ??? ??, ??? ??? ?? ??? ??? ???????
?? ? ??? ? ??? ?? ABS????, ? ?? ?? ? ??(????)? ???????
?? ? ??? ?????
????BX ????? ?????? ????? ?? ? ??? ?????
???? ? ?? ? ???? System? ????? ?? ? ???? ?????
??? ?? ???? ????? AGM ???? ??? ?? ?? ? ??? ?????
???? ? ?????
??????? ??? ??? ?? ???? ????? ???? ????? ??? ????.
KBA ???? -15℃∼45℃? ???? ???? ??? ?????
?? ??? ??? ? ??? ???? ????? ???? ?? ?? ????? ?????
??? ????? ???? ? ??? ???? ????, ??? ?? ? ??? ?????
集交流輸入過、欠壓保護,輸出過載、短路保護,逆變器過熱保護、IGBT過流保護、電池欠壓預警保護和電池過充電保護等多功能保護于一體,很大地保證了系統運行的穩定性和可靠性。
具有旁路功能,當輸出過載或UPS發生故障時,可無間斷地轉到旁路工作狀態由市電繼續向負載供電,并提供報警信息。具有輸入零火線偵測功能。可避免UPS市電輸入零火線接反
冷啟動和市電啟動功能
市電異常狀況可以直接用電池啟動UPS,滿足應急需求。無電池狀態可直接采用市電啟動UPS,可作高精度穩壓電源使用。可搭配發電機使用輸入電壓與頻率范圍廣,能有效隔離發電機產生的不良電力,為負載提供潔凈、安全、穩定的電源。
零切換
雙變換在線式設計,使UPS的輸出為頻率跟蹤、鎖相穩壓、濾除雜訊、不受電網波動*的純凈正弦波電源,為負載提供更全面保護。市電不穩定時,UPS供電模式的轉換時間為零,有效保證了負載運行的安全性和可靠性。
智能化電池管理
采用智能電池管理技術,使用三段式充電,有效的延長電池使用壽命,減少電池維護次數;可定期的對電池進行自檢,及時的發現電池問題。設有電池過壓,過充等保護功能,大限度保護電池不損壞。
強大的擴展性功能
智能插槽能提供豐富的可擴展功能,可選擇UPSmart2000監控軟件、SNMP卡、RS485、AS400卡、EMD環境監測器UPS不間斷電源參數UPS不間斷電源的組成結構
UPS的作用
UPS具有以下幾項基本功能:
1.電網電壓正常時,市電電壓通過UPS穩壓后供應給負載使用,性能好的UPS本身就是良好的交流穩壓器,同時改善電源質量;同時它還對機內的電池進行充電,儲存后備能量。
2.電網電壓異常時(欠壓、過壓、掉電、*等)UPS的逆變器將電池的直流電能轉換為交流電能維持對負載的供電。
3.UPS在電網供電和電池供電之間自行切換,確保對負載的不間斷供電。而且可以根據設備的精密程度來選擇可承受的切換時間。隔離變壓UPS電源帶隔離變壓器的UPS電源。
U.P.S (?? ? ????) ? | ????? ? | ???? ? | ??? ? |
????? | ?????? | ???????? | ????? |
???? | ????? ???? |
|
|
?? | ?? | ???? | ????(mm) | ?? | |||||||
?? | ?? | ?? | ?? | ?? | ??(L) | ?(W) | ??(H) | ??? | |||
KBA2100 | 2 | 100 | 91 | 83 | 65 | 50 | 106 | 170 | 329 | 344 | 9.5 |
KBA2150 | 2 | 150 | 136 | 124 | 98 | 75 | 106 | 170 | 329 | 344 | 10.0 |
KBA2200 | 2 | 200 | 182 | 166 | 130 | 100 | 106 | 170 | 329 | 344 | 12.5 |
KBA2250 | 2 | 250 | 227 | 207 | 163 | 125 | 195 | 170 | 329 | 344 | 17.0 |
KBA2300 | 2 | 300 | 273 | 249 | 195 | 150 | 195 | 170 | 329 | 344 | 19.0 |
KBA2400 | 2 | 400 | 364 | 332 | 260 | 200 | 195 | 170 | 329 | 344 | 24.0 |
KBA2500 | 2 | 500 | 455 | 415 | 325 | 250 | 285 | 170 | 329 | 344 | 30.0 |
KBA2600 | 2 | 600 | 546 | 498 | 390 | 300 | 285 | 170 | 329 | 344 | 35.0 |
KBA2700 | 2 | 700 | 637 | 581 | 455 | 350 | 382 | 170 | 329 | 344 | 43.0 |
KBA2800 | 2 | 800 | 728 | 664 | 520 | 400 | 382 | 170 | 329 | 344 | 48.0 |
KBA2900 | 2 | 900 | 819 | 747 | 585 | 450 | 471 | 170 | 329 | 344 | 55.0 |
KBA21000 | 2 | 1000 | 910 | 830 | 650 | 500 | 471 | 170 | 329 | 344 | 62.0 |
KBA21200 | 2 | 1200 | 1092 | 996 | 780 | 600 | 471 | 170 | 329 | 344 | 69.0 |
KBA21400 | 2 | 1400 | 1274 | 1162 | 910 | 700 | 472 | 332 | 340 | 352 | 89.0 |
KBA21600 | 2 | 1600 | 1456 | 1328 | 1040 | 800 | 472 | 332 | 340 | 352 | 98.0 |
KBA21800 | 2 | 1800 | 1638 | 1494 | 1170 | 900 | 472 | 332 | 340 | 352 | 105.0 |
KBA22000 | 2 | 2000 | 1820 | 1660 | 1300 | 1000 | 472 | 332 | 340 | 352 | 121.0 |
KBA22200 | 2 | 2200 | 2002 | 1826 | 1430 | 1100 | 472 | 332 | 340 | 352 | 126.0 |
KBA22400 | 2 | 2400 | 2184 | 1992 | 1560 | 1200 | 472 | 332 | 340 | 352 | 136.0 |
注:>24AH電池額外容量以10小時率計,≤24AH電池額外容量以20小時率計;容量為25℃下的平均值。
????????? 27? ?? ?????? ??? ?????, ??? ??????? ?? ????, ??? ??????? ?????? ?
??? 10? ?? ??? ??? ??? ????????? ?? 2000? ?? ????? ???.
???????? ?? 2012??? ?? ??? ??? ????? ???? ???? ??? ?????????? ? 1? ?? ??? ???? ?? ?? ??·??? ???? ??.
用于數據中心項目的發電機組及其部件的特性與用于其它設施的備用機組的特性大都相同,盡管DCC機組對某些部件的選擇要求會更嚴。
所有部件中重要的是發動機,因為發電機組電力產生來源于它。用于DCC項目的發動機必須帶有電子調速器,這樣無論何時電網發生故障,要求它啟動時都能快速調到合適的電壓和頻率。這些參數一旦確立,發動機能在以后的運行中維持不變。決定選用的發動機容量大小時,不僅要考慮以上提到的數據中心應用的這些因素,同時也要考慮其他所有項目通用的環境因素,如環境溫度和海拔。
為有嚴格可靠性要求的數據中心項目選擇發動機,啟動系統是非常重要的。如HIMOINSA公司可以通過2臺帶獨立電池系統的電動馬達組成的冗余啟動系統或1臺電動馬達加1臺氣動或液壓馬達的組合提高發電機標配啟動系統的可靠性。
選擇能給啟動系統提供足夠電能的免維護電池也很關鍵。此外,與所有備用電源應用相同,為了保證快速啟動并迅速帶負荷,使用電阻加熱器對發動機缸體內的冷卻液加熱很重要。這樣,當發生電網故障時,發動機才能處于合適的溫度。加熱電阻可加裝一個泵來幫助冷卻液循環,讓發動機機體冷卻液溫度更加均衡*。后,利用油泵進行預潤滑也會提升啟動速度。
發電機是發電機組另一個關鍵部件。一個高效的AVR(自動電壓調節)能保持電壓變化值低于0.5%;一個設計合理的繞組能維持低諧波失真率和電信*值。使用PMG勵磁可為AVR提供獨立于主繞組的電源,在突然加載時也能可靠運行,以此保證調節器保持良好的勵磁輸出。繞組高質量的浸漆、IP23防護等級、防潮加熱器,對于發電機組的持續運行至關重要,尤其是在環境濕度高的地方。
在數據中心設施里,發電機組有時安裝在底層或地下,讓外面的空氣自由進入的通道很少,冷卻裝置的選擇也很重要。因此發電機組生產商必須有一個經驗豐富的工程團隊,設計通過中間冷卻器和二次回路的方法,在更高的樓層或屋頂安裝遠程冷卻系統。如在阿里巴巴集團數據中心,HIMOINSA公司提供24MW備用電源,設計有一個遠程冷卻系統,臥式散熱器安裝在大樓頂層。
發電機組的控制器負責控制、監測和操作上述所有要素。市面上有不同品牌的控制器,用于不同的應用。HIMOINSA公司有專門控制自己生產的發電機組而設計的控制器,它們能檢測到電網故障,通過指令啟動發電機組。發電機組的運行參數及警報位于建筑物里的樓宇管理系統中,為使它們與發電機組實現一體化,HIMOINSA控制器支持不同的通信協議。
由于網頁資源有限,具體電池型號、參數、價格咨詢請致電。另外我們還為客戶提供技術咨詢服務,說出您的負載、延時時間等,我們會有的工程師為您提供ups電源、電池解決方案,讓您真正的后顧無憂!