參 考 價 | 面議 |
更新時間:2016-08-25 10:21:27瀏覽次數(shù):1272次
聯(lián)系我時,請告知來自 化工儀器網(wǎng)KANOMAX風(fēng)速儀65Ser環(huán)境測試儀
與KA22/31相比,體積縮小30%,電池壽命延長25%。
3.5inch彩色大屏幕,風(fēng)速、風(fēng)溫、壓力同時顯示。
數(shù)字、模擬雙視圖顯示、具備三級亮度背光選擇功能。
具備風(fēng)速判定測試模式,任意設(shè)置上下限。
具備風(fēng)速統(tǒng)計計算功能。
產(chǎn)品參數(shù):
名 稱 | KANOMAX風(fēng)速儀KA33熱式風(fēng)速計 | ||
型 號 | KA23 | KA33 | |
測試對象 | 常 溫常圧下潔凈的空氣流 | ||
測試范圍 ( 分辨率 ) | 風(fēng) 速 | 0.00~ 50.0m /s (0.00~ 9.99m /s 時,分辨率 0.01m /s 。 10.0~ 50.0 m /s 時,分辨率 0.1m /s ) | |
風(fēng) 溫 | - 20.0~ 100.0 ℃ ( 分辨率 0.1 ℃ ) | ||
壓 力 * | 無 | 0.00 ~ ±5.00 kPa( 分辨率 0.01kPa ) | |
測試精度 | 風(fēng) 速 | 0.00~ 4.99m /s ± 2%FS 5.00~ 50.0m /s ± 2%FS | |
風(fēng) 溫 | ± 0.3℃ ( -20℃ ~ 0℃ , 60℃ ~ 100℃ 范圍內(nèi)為 ± 0.5℃ ) | ||
壓 力 * | 無 | ±0.1kPa | |
測試機能 | • 具備三級亮度背光選擇功能。 • 具備數(shù)據(jù)保持和風(fēng)速的快 / 慢速測試功能。 • 具備電池電量不足的提示功能。 • 具備風(fēng)速上下限判定測量模式功能。 • 具備風(fēng)速的 zui大值、zui小值、平均值的測量功能。 | ||
本體外形尺寸 | 本體: 157 ( W ) × 43 ( H ) × 80 ( D ) mm | ||
箱體: 167 ( W ) × 66 ( H ) × 88 ( D ) mm | |||
探頭尺寸 | zui粗把手部分Ф 15mm ,收起后探頭長度 140mm ,拉伸后探頭長度 235 mm . | ||
探頭電纜長度 | 2.5 m | ||
電 源 | AA 堿性電池 4 節(jié) | ||
電池壽命 | 約 10 小時 (風(fēng)速 5 m /s ,風(fēng)溫 20 ℃ , AA 堿性電池) | ||
使用環(huán)境 | 本 體 | 5 ~ 40℃ | |
探 頭 | -20 ~ 100℃ | ||
保存溫度 | -30 ~ 60℃ | ||
重 量 | 約 450g (含電池、探頭、箱體) | ||
隨機附件 | 手提箱 1 個;使用說明書 1 本;探頭延長棒 1 支;靜壓測試膠管 1.5m * ;
|
Never bring the probe close to a flammable gas atmosphere.
The heated sensor may cause a fire or explosion.
Never touch the sensor.
The sensor is heated during operation. Touching the heated sensor
may cause burns, and may also damage the sensor itself.
Do not disassemble or heat the batteries, or put them into a fire.
This may cause burns and the batteries may burst.
If abnormal noises, smells or smoke occur, or if liquid enters the instrument, turn off the instrument immediay, and remove the batteries or pull out the plug.
There is possibility of malfunction, electric shock, and/or fire. Please contact your local distributor or our service center for repair.
Always unplug the instrument from the electrical outlet when the instrument is not in use.
Failure to do so may cause an electrical shock, fire or circuit damage.
Do not use the instrument in a water vapor atmosphere.
Condensed steam on the sensor will change the heat dissipation rate,resulting in inaccurate measurements. It may also cause damage to the sensor.
This instrument is designed to be used in an environment with a clean air stream without any dust or foreign materials.
Foreign materials may cause damage to the sensor. Also dust or foreign materials on the sensor will impede accurate measurements.
Do not apply force to the sensor.
If the sensor is deformed, the accuracy of the sensor may beaffected.
When measuring, ensure that the direction mark is facing into the airflow.
Otherwise, the measurement may be inaccurate, as some sensors
(uni-directional probes) have a specific directivity.