亚洲中文久久精品无码WW16,亚洲国产精品久久久久爰色欲,人人妻人人澡人人爽欧美一区九九,亚洲码欧美码一区二区三区

| 注冊| 產品展廳| 收藏該商鋪

行業產品

當前位置:
廣州尖分科學儀器有限公司>>戴安 Dionex>>Bio Columns>> CarboPac PA20 Carbohydrate Column

CarboPac PA20 Carbohydrate Column

返回列表頁
  • CarboPac PA20 Carbohydrate Column
收藏
舉報
參考價 面議
具體成交價以合同協議為準
  • 型號
  • 品牌
  • 廠商性質 代理商
  • 所在地 廣州市
在線詢價 收藏產品

更新時間:2016-10-27 15:59:32瀏覽次數:421

聯系我們時請說明是化工儀器網上看到的信息,謝謝!

同類優質產品

更多產品

產品分類品牌分類

更多分類

產品簡介

CarboPac PA20 Carbohydrate ColumnThe Thermo Scientific Dionex CarboPac™ PA20 column line has been expanded to include a new 0.4 × 150 mm capillary column and a new Dionex CarboPac PA20 Fast Sialic Aci

詳細介紹

Fast, Sensitive Mono- and Disaccharide Analysis

The Thermo Scientific Dionex CarboPac PA20 column line has been expanded to include a new 0.4 × 150 mm capillary column and a new Dionex CarboPac PA20 Fast Sialic Acid column.

As with all CarboPac PA20 columns, the new capillary format provides high-resolution separations of mono- and disaccharides with no need for derivatization. The Dionex CarboPac PA20, 0.4 × 150 mm format offers the additional advantages of higher mass sensitivity, lower sample amount requirements, and significantly lower solvent use.

The new Dionex CarboPac PA20 Fast Sialic Acid column is ideally suited for the fast analysis of sialic acids in glycoprotein acid hydrolyzates. The Dionex CarboPac PA20 Fast Sialic Acid column accelerates sialic acid determination allowing sample analysis in less than five minutes. The Dionex CarboPac PA20 Fast Sialic Acid column is packed with the same hydrophobic, polymeric, pellicular anion exchange resin as the Dionex CarboPac PA20 column, but in a 3 x 30 mm column format.

The Dionex CarboPac PA20 is a strong anion-exchange column that provides high-resolution separations of mono- and disaccharides with no need for derivatization. This column provides baseline resolution between the six monosaccharides commonly found in mammalian glycoproteins over a wide range of eluent concentrations. The Dionex CarboPac PA20 provides slightly different selectivity from either the Dionex CarboPac PA1 or Dionex CarboPac PA10, making it an attractive choice for separating difficult peak pairs.

  • The column of choice for high-sensitivity monosaccharide analyses

  • Highly efficient separations with good resolution between neighboring peaks

  • Fast analysis—less than 10 min

  • Optimized resolution of glucosamine/galactose and glucose/mannose peak pairs

  • Lower eluent consumption

  • Does not require derivatization

The Dionex CarboPac PA20 consists of 6.5 µm-diameter nonporous beads covered with a fine latex of functionalized Thermo Scientific Dionex MicroBead resin. This pellicular resin structure permits excellent mass transfer, resulting in high-resolution chromatography and rapid re-equilibration. The performance of each column is verified with a Thermo Scientific Dionex MonoStandard.

Dionex CarboPac PA20 Column for Fast Monosaccharide Analysis Specifications
DimensionsDionex CarboPac PA20 Analytical Column:
3 × 150 mm
Dionex CarboPac PA20 Capillary Column:
0.4 × 150 mm
Dionex CarboPac PA20 Fast Sialic Acid Column:
3 × 30 mm
Dionex CarboPac PA20 Guard Column:
3 × 30 mm
Maximum operating pressure3000 psi (21 MPa)
Temperature range4–60 °C
Recommended operating temperature: 30 °C
Typical operating conditionsTest procedure: Baseline resolution of fucose, galactosamine, glucosamine, galactose, glucose, mannose.
Dionex CarboPac PA20 Analytical Column recommended flow rate: 0.5 mL/min
Dionex CarboPac PA20 Capillary Column recommended flow rate: 8 µL/min
Dionex CarboPac PA20 Fast Sialic Acid Column recommended flow rate: 0.5 mL/min
phase compatibilitypH 0–14;
* compatible with common HPLC solvents and * water.
Ionic form eluents: sodium hydroxide, sodium acetate.
Resin composition6.5 µm-diameter substrate (ethylvinylbenzene 55% crosslinked with divinylbenzene) agglomerated with 130 nm MicroBead difunctional quaternary ammonium ion (5% crosslinked).
Anion-exchange capacityApproximay 65 µeq/column (3 × 150 mm analytical column)
Approximay 1.16 µeq/column (0.4 × 150 mm capillary column)
Approximay 13 µeq/column (0.3 x 30 mm Fast Sialic Acid column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
 