產品簡介
詳細介紹
High Resolution, High-Capacity Cation-Exchange Column for the Separation of Small Polar Amines
Attain the optimal combination of chromatographic speed and resolution using the new Thermo Scientific™ Dionex™ IonPac™ CS19-4µm cation-exchange column. This high capacity, high resolution capillary column provides excellent resolution of common cations, small polar amines and polyvalent amines in complex sample matrices. Compared to the previous Dionex IonPac CS19 column, the new ion-exchange column uses smaller resin particles for more efficient separations resulting in faster analysis, more accurate peak integration, and more reliable results.
The Dionex IonPac CS19-4µm carboxylate-functionalized cation-exchange column has similar selectivity to the Dionex IonPac CS19 column for the six common cations, small polar amines (including alkanolamines and methylamines) and moderay hydrophobic and polyvalent amines (including biogenic amines and alkyl diamines). Applications run on the Dionex IonPac CS19 column can be easily transferred to the Dionex IonPac CS19-4µm column with the benefit of increased peak resolution which provides more consistent results. The Dionex IonPac CS19-4µm column is available in three formats, standard bore (4 × 250 mm), microbore (2 × 250 mm), and capillary (0.4 × 250 mm). The capillary and microbore formats require less eluent thereby reducing operating costs.
Increase speed, chromatographic resolution and quality of analytical results
For analysis of amines including alkanolamines and methylamines in diverse sample matrices
For analysis of moderay-hydrophobic amines including biogenic amines, alkyl diamines, and polyvalent amines
Optimized for fast simple acidic gradient separations with minimal baseline shift
High capacity allows routine analysis of high-ionic-strength samples
The Dionex IonPac CS19-4µm column is targeted for analysis of power plant waters treated with ammonium, morpholine, or ethanolamine; as well as chemical additives; chemical process solutions; scrubber solutions; personal care products; and food samples.
The smaller resin particles used in the Dionex IonPac CS19-4µm column produce increased backpressure. When operating the Dionex IonPac CS19-4µm microbore or capillary column at standard flow rate, an IC system capable of operating up to 3000 psi is sufficient. However, to take advantage of the fast runs, using elevated flow rates, a high pressure IC system, such as the Thermo Scientific Dionex ICS-5000+ HPIC or Dionex ICS-4000 HPIC is required. The Dionex ICS-5000+ HPIC system is required for standard operation of the Dionex IonPac CS19-4µm standard bore column.
Thermo Scientific Dionex IonPac™ CS19-4µm Cation-Exchange Column Specifications | |
---|---|
Dimensions: | Dionex IonPac CS19-4µm Analytical Column: 4 × 250 mm Dionex IonPac CG19-4µm Guard Column: 4 × 50 mm Dionex IonPac CS19-4µm Analytical Column: 2 × 250 mm Dionex IonPac CG19-4µm Guard Column: 2 × 50 mm Dionex IonPac CS19-4µm Capillary Column: 0.4 × 250 mm Dionex IonPac CG19-4µm Capillary Guard Column: 0.4 × 50 mm |
Maximum Operating Pressure: | 5000 psi (34 MPa) |
Phase Compatibility: | Acidic eluents, 0–10% HPLC solvents, excluding alcohols |
Substrate Characteristics: | Bead Diameter: 4 µm supermacroporous Crosslinking (%DVB): 55% |
Functional Group Characteristics: | Ion-Exchange Group: Grafted carboxylic acid Surface Characteristics: Medium hydrophobic |
Capacity: | 2410 µeq (4 × 250 mm analytical column) 46 µeq (4 × 50 mm guard column) 600 µeq (2 × 250 mm analytical column) 11 µeq (2 × 50 mm guard column) 24 µeq (0.4 × 250 mm capillary column) 0.5 µeq (0.4 × 50 mm capillary guard column) |
Column Construction: | PEEK™ with 10-32 threaded ferrule style end fittings. All components are nonmetallic. |