閱讀:636 發布時間:2015-3-11KIMRAY正作用低溫關斷器圖紙下載專業現貨銷售進口美國KIMRAY 燃氣減壓閥;凱姆雷減壓閥詳細參數如下:適用于天然氣系統區域控制及工業、公共用戶的調壓器
調壓、關閉靈敏、壓力設定簡單大皮膜執行機構組合指揮器使得調壓器動作靈敏,反應速度快
一體化的過壓、失壓切斷裝置,確保用戶安全可在線維修可作監控連接,保證安全
流通能力大,結構緊湊;密封嚴密,無氣體滲漏安裝省力,經濟實惠
進口壓力范圍:200kg出口壓力范圍:15kg流量:1500m3/h精度:±2.5%
連接方式:1"材料:鑄鐵,韌性鑄鐵或WCB 鋼制閥體
溫度:-29°~66℃選項:可在指揮器前配置過濾器
內置超高壓/超低壓切斷裝置
大皮膜執行機構組合指揮器使得調壓器動作靈敏,反應速度快
ACTION:Direct; Pilot Output Pressure (Yellow) increases with temperaturerise.
APPLICATION:For temperature controlled system shutdown until manuallyreset.
WORKING PRESSURE (sensing element):psig kg/cm2
500 35.15 max. without Separable Socket
4000 281.23 max. with Separable Socket
7000 492.15 max. with Special Separable Socket
Separable Socket is an extra price item and must be ordered separay, if desired. To order Separable Sockets refer to Table of Contents.
TEMPERATURE RANGE:
-30°F minimum to 400°F maximum
-34°C minimum to 204°C maximum
SUPPLY PRESSURE:
5 to 30 psig
.35 to 2.11 kg/cm2KIMRAY正作用低溫關斷器圖紙下載
OPERATION:
This Thermostat consists of a Direct Action Base Assembly sending a signal to a 3 PGM Pilot. The 3 PGM Pilot is connected so that once the Output Pressure (Yellow) is vented, it must be manually reset to resume service.
Assume the set temperature of the Thermostat is below that of the system. The vents at BALL 1 (Orange to Atmosphere) and
BALL 3 (Yellow to Atmosphere) are closed. The Inlets at BALL 2 (Yellow to Orange) and BALL 4 (Violet to Yellow) are open. Output Pressure (Yellow) is being sent to any Pilot or Motor Valve.
As the temperature decreases in the system, the STAINLESS TUBE decreases in length to move the Thermostat Diaphragm Assembly in a direction to first close the seat at BALL 2 (Yellowto Orange) and open the seat at BALL 1 (Orange to
Atmosphere). Venting Variable Pressure (Orange) moves the 3PG Pilot Diaphragm Assembly upward to close the seat at BALL
4 (Violet to Yellow) and open the seat at BALL 3 (Yellow to Atmosphere). Output Pressure (Yellow) decreases to cause the
desired Pilot or Motor Valve action.
Once the Output Pressure (Yellow) has been vented the Thermostat is shut-down until the temperature of the system is
above the set temperature and the RESET LEVER is used to reset the Pilot. If desired the RESET LEVER can also be used
to manually vent Output Pressure (Yellow) and shut-down the thermostat.