亚洲中文久久精品无码WW16,亚洲国产精品久久久久爰色欲,人人妻人人澡人人爽欧美一区九九,亚洲码欧美码一区二区三区

產品展廳收藏該商鋪

您好 登錄 注冊

當前位置:
世聯博研(北京)科技有限公司>供求商機>BT-CS,STIM-AT,HLD-CS-cellmc,Cell MicroControls細胞電刺激培養腔裝置,細胞灌流電刺激腔室裝置系統
BT-CS,STIM-AT,HLD-CS-cellmc,Cell MicroControls細胞電刺激培養腔裝置,細胞灌流電刺激腔室裝置系統
返回列表頁
  • BT-CS,STIM-AT,HLD-CS-cellmc,Cell MicroControls細胞電刺激培養腔裝置,細胞灌流電刺激腔室裝置系統

舉報
貨物所在地: 北京北京市
地: 美國
更新時間: 2024-10-30 21:00:07
期: 2024年10月30日--2025年4月30日
已獲點擊: 421
在線詢價收藏產品

(聯系我們,請說明是在 化工儀器網 上看到的信息,謝謝!)

產品簡介

低成本可重復使用培養/刺激室
刺激/熱敏電阻總成(STIM-AT)壓入到位 - 無需工具
?低成本可重復使用的文化刺激室(BT-CS)
- 體積小,層流,流入/流出口,#1玻璃底
?刺激/熱敏電阻總成(STIM-AT)壓入到位 - 無需工具
?用于腔室,吸氣器的支架(HLD-CS)
?所有流行顯微鏡的顯微鏡級適配器(MSA-NIK,MSA-TS100,MSA-OL11,MSA-LEI / DM

詳細介紹

cellmc,Cell MicroControls細胞電刺激培養腔裝置,細胞灌流電刺激腔室裝置系統

cellmc,Cell MicroControls細胞電刺激培養腔裝置,細胞灌流電刺激腔室裝置系統

 

 n Low cost reusable culture/stim chamber (BT-CS)

-small volume, laminar flow, inflow/outflow port, #1 glass bottom

n Stimulation/thermistor assy (STIM-AT) presses into place-no tools required

n Holder (HLD-CS) for chamber, aspirator

n Microscope stage adapters (MSA-NIK, MSA-TS100, MSA-OL11, MSA-LEI/DM, MSA-MZ etc.) for all popular micro­scopes

n BT-CS fits Ionoptix Corp C-Dish for stimulation during culture

DESCRIPTION

The Culture Chamber system uses a low cost but complete cell perfusion chamber (BT-CS) for holding cells or small pieces of tissue and then transferring them to a microscopy or electrophysiology setup. The BT-CS has an inflow tube and area for aspirating solution and has laminar flow over a range of flow rates. The Stimulation/thermistor assy (STIM-AT) presses into the Chamber holder (HLD-CS). The unique design of the stimulation electodes is such that they clip into a small recess cut along the front and rear lower edges of the chamber. They can be rebent to their original shape if they are accidentally dam­aged. The aspirator is postioned with the FL-1 Miniature postioner attached to the HLD-CS.

In a typical setup with temperature control the HPRE2 Pre-heater is used for heating the chamber. perfusate The MPRE8 8 channel pre-heater can be used to superfuse a region of the chamber. These can both be controlled by the TC2BIP Tem­perature Controller for electrophysiology or mTCII micro-Temperature Controller for microscopy. If the TC2BIP is equiped with the third channel (TC2-Ch3) the temperature in the chamber can be monitored with the thermistor built into the Stimulation/thermistor assy.

The Chamber holder fits into the Microscope stage adapter. These are available for most popular microsopes (see our website for further information).

Specifications

BT-CS: Central chamber-volume 0.3ml

- 13x12mm

- aspiration port matches male Luer for priming

- supplied with #1 cover slide attached

- polycarbonate (autoclavable)

STIM-AT: Platinum Iridium stimulation wires, snaps into HLD-CS

HLD-CS: Holds BT-CS, STIM-AT and FL-1. Fits into MSA-XXX stage adapters

收藏該商鋪