亚洲中文久久精品无码WW16,亚洲国产精品久久久久爰色欲,人人妻人人澡人人爽欧美一区九九,亚洲码欧美码一区二区三区

深圳華清儀器儀表有限公司

奧林巴斯D798測厚儀探頭

時間:2017-11-20閱讀:633
分享:

D798|D798測厚儀探頭|奧林巴斯D798測厚儀探頭|奧林巴斯OLYMPUS/D798測厚儀探頭|D798測厚儀雙晶探頭

奧林巴斯D798測厚儀雙晶探頭|奧林巴斯OLYMPUS/D798測厚儀雙晶探頭

27MG測厚儀

45MG測厚儀

38DL PLUS測厚儀

MAGNA-MIKE 8600測厚儀

35RDC測厚儀

深圳華清儀器儀表有限公司優惠價供應奧林巴斯系列產品,具體想了解D791-?RM價格、D791-?RM貨期、D791-?RM實物圖、D791-?RM應用等等,請來電與深圳華清儀器無損檢測部,謝謝 

Gage Dual Transducers

Request a quote or purchase a transducer by selecting the item number.

Item NumberPart CodeFrequency
(MHz)
Connector TypeConnector LocationRange in Steel (mm)Range in Steel (in)Temperature Range °FTemperature Range °CTip Diameter (mm)Tip Diameter (in)

U8450017

D797-?SM

2MicrodotStraight3.5 - 6350.150 - 25-5 - 752-20 - 40022.90.900

U8450016

D797

2PottedRight Angle3.5 - 6350.150 - 25-5 - 752-20 - 40022.90.900

U8454038

D7910

5PottedRight Angle1.00 - 500.000.040 - 20.00032 -1220 - 5012.70.5

U8450021

D799

5PottedRight Angle1.0 - 5080.040 - 20-5 - 300-20 - 150110.434

U8450007

D790-?RL

5LEMORight Angle1.0 - 5080.040 - 20-5 - 932-20 - 500110.434

U8450008

D790-?SL

5LEMOStraight1.0 - 5080.040 - 20-5 - 932-20 - 500110.434

U8450009

D790-?SM

5MicrodotStraight1.0 - 5080.040 - 20-5 - 932-20 - 500110.434

U8450011

D791-?RM

5MicrodotRight Angle1.0 - 5080.040 - 20-5 - 752-20 - 400110.434

U8450002

D790

5PottedStraight1.0 - 5080.040 - 20-5 - 932-20 - 500110.434

U8620225

MTD705

5Lepra/ConRight Angle1.0 - 190.040 - 0.7532 - 1220 - 505.10.200

U8450010

D791

5PottedRight Angle1.0 - 5080.040 - 20-5 - 932-20 - 500110.434

U8450014

D794

5PottedStraight0.75 - 500.030 - 232 - 1220 - 507.20.283

U8450018

D798

7.5PottedRight Angle0.71 - 1000.028 - 4-5 - 300-20 - 1507.20.283

U8450020

D798-?SM

7.5MicrodotStraight0.71 - 1000.028 - 4-5 - 300-20 - 1507.20.283

U8450019

D798-?LF

7.5PottedRight Angle0.71 - 1000.028 - 4-5 - 300-20 - 1508.90.35

U8454013

D7226

7.5PottedRight Angle0.71 - 1000.028 - 4-5 - 300-20 - 1508.90.35

U8450012

D792

10PottedStraight0.5 - 250.020 - 132 - 1220 - 507.20.283

U8450013

D793

10PottedRight Angle0.5 - 250.020 - 132 - 1220 - 507.20.283

Other Thickness Gage Transducers

For use with 38DL PLUS and 45MG.

* Oxide Software only available for 38DL PLUS.

**E110-SP not available for 45MG.

Adaptor required for E110 (part number 1/2XA/E110).

Transducer
Part #

Part 
Number

Freq.

Tip Diameter

Transducer Type

Connector

Range in Steel

Temp. Range

 

 

MHzin.mm

 

TypeLocationin.mm°F°C

V260-SM

U8411019

15

0.080

2

Sonopen®

Microdot®

Straight

0.02 - 0.400

0.5 - 10

32 to 122

0 to 50

V260-RM

U8411018

15

0.080

2

Sonopen

Microdot

Right Angle

0.02 - 0.400

0.5 - 10

32 to 122

0 to 50

V260-45

U8411017

15

0.080

2

Sonopen

Microdot

45? Handle

0.02 - 0.400

0.5 - 10

32 to 122

0 to 50

M2017*

U8415002

20

0.250

6.35

Internal Oxide Scale

Microdot

Right Angle

Steel: 
0.020 - 0.50 
Oxide: 
0.010 - 0.050

Steel: 
0.5 - 12 
Oxide: 
0.25 - 1.25

32 to 122

0 to 50

M2091*

U8415018

20

0.250

6.35

Replaceable Delay Line Shear Wave

Microdot

Right Angle

Steel: 
0.020 - 0.50 
Oxide: 
0.006 - 0.050

Steel: 
0.5 - 12 
Oxide: 
0.150 - 1.25

32 to 122

0 to 50

E110-SB†**

U8471001

-

1.25

28.5

EMAT

BNC

Straight

0.080 - 5

2.0 - 125

32 to 176

0 to 80

Gage Dual Cables

Cable Part Number

Part Code

For Use With

Length

Cable Type

Plug Type

 

 

 

feet

meters

 

 

LCMD-316-5B

U8800353

D790-SM

5.0

1.5

Standard

Straight

RLCMD-316-5B

U8800367

D790-SM

5.0

1.5

Standard

Rt Angle

LCMD-178-5B SSA

U8800352

D790-SM

5.0

1.5

Armored

Straight

RLCMD-178-5B SSA

U8800366

D790-SM

5.0

1.5

Armored

Rt Angle

LCLD-316-5G

U8800330

D790-RL

5.0

1.5

Standard

Straight

LCLD-316-5H

U8800331

D790-SL

5.0

1.5

Standard

Straight

LCMD-316-5C

U8800354

D791-RM

5.0

1.5

Standard

Straight

LCMD-316-5D

U8800355

D797-SM

5.0

1.5

Standard

Straight

LCMD-316-5J

U8800357

D798-SM

5.0

1.5

Standard

Straight

LCMD-316-5L

U8800358

D7906-SM

5.0

1.5

Standard

Straight

LCLPD-78-5

U8800332

MTD705

5.0

1.5

Standard

Straight

LCM-74-4

U8800348

V260-SM, V260-RM, V260-45, M2017

4.0

1.2

Standard

-

LCM-188-4 SSA

U8800342

V260-SM, V260-RM, V260-45, M2017

4.0

1.2

Armored

-

LCB-74-4

U8800320

E110-SB

4.0

1.2

Standard

-

The Panametrics-NDT Microscan transducers are frequently used with the Series 25 and Series 35 thickness gages, as well as other commercially available thickness gages, flaw detectors and ultrasonic instrumentation.

Microscan transducer part numbers reflect the connector designation: 
RM = Right Angle Microdot® 
SM = Straight Microdot 
RB = Right Angle BNC 
SB = Straight BNC 
SU = Straight UHF

When selecting a transducer, please review the chart below or consult the Transducer Frequency Range in the Instruction Manual that was shipped with your gage.

Thickness Gage Model

Transducer Frequency Range

45MG 
38DL PLUS

2.0 to 30 MHz

 

Contact Transducers

 

One of the advantages of a Panametrics-NDT Microscan contact transducer is its versatility; a single transducer can cover a broad thickness range in many engineering materials. Contact transducers are constructed with the unique WC-5 wearplate for greater durability and a longer life.

Frequency 
(MHz)
Element 
inches
Diameter 
mm
Transducer 
Part Number
Transducer 
Part Code
0.5125M101-SBU8400017
1125M102-SBU8400018
10.513M103-SBU8400020
2.250.513M106-RM, M106-SMU8400023, U8400025
2.250.513M1036†U8400019
50.513M109-RM, M109-SMU8400027, U8400028
50.256M110-RM, M110-SM, M110H-RM**U8400030, U8400031, U8400029
100.256M112-RM, M112-SM, M112H-RM**U8400034, U8400035, U8400033
100.1253M1016U8400015
200.1253M116-RM, M116-SMU8400038, U8400039
200.1253M116H-RM*U8400037

RM = Right Angle Microdot; SM = Straight Microdot; SB = Straight BNC 
†High Penetration Transducer *Use with Holder, P/N 2133 **Use with Holder, P/N 2132

SONOPEN® Transducers

The Sonopen® transducer has a replaceable delay line that is tapered to a small contact area. This transducer makes reliable thickness measurements in applications such as turbine blades, threads on plastic bottle necks and tight radii on plastic containers. High-temperature Sonopen delay lines are also available.

Frequency

Nominal 
Element Size

Transducer 
Part Numbers

MHz

inches

mm

Straight 
Handle

Right Angle 
Handle

45° 
Handle

15

0.125

3

V260-SM 
U8411019

V260-RM 
U8411018

V260-45 
U8411017

Tip diameter

 

inchesmmPart Number
0.082DLP-3
0.061.5DLP-302
0.082DLP-301*

*High temperature delay for use up to 350° F (175° C)

Delay Line Transducers

Panametrics-NDT Microscan delay line transducers provide excellent performance on very thin materials, elevated temperatures or in applications that require a high degree of thickness resolution.

Frequency 
(MHz)
Element 
inches
Diameter 
mm
Transducer 
Part Number
Transducer 
Part Code
Holders
0.5125M2008U8415001-
2.250.513M207-RBU8410017-
50.513M206-RBU8410016-
50.256M201-RMU8410001-
50.256M201H-RMU84110302127
100.256M202-RM, M202-SMU8410003, U8410004-
100.256M202H-RMU85070232127
100.1253M203-RM, M203-SMU8410006, U8410007-
200.1253M208-RM, M208-SMU8410019, U8410020-
200.1253M208H-RMU84100182133
200.1253M2055*U8415013-
300.256V213-BC-RM*U8411022-

 

Replaceable Delay Lines

Standard Delay Lines

Standard delay lines are used in many applications. Special conditions such as high surface temperature, curvature of the material or hard-to-access areas may require the use of special delay lines.

Element 
Diameter
Delay Line Part NumberMaximum Thickness 
Measurement Limit*
Steel 
Mode 2
Steel 
Mode 3
Plastic 
Mode 2
inchesmminchesmminchesmminchesmm
0.513DLH-21.0250.5130.513
0.256DLH-11.0250.5130.513
0.1253DLH-30.5130.250.25

*Exact range depends on material sound velocity, transducer frequency, part geometry and surface condition.

High Temperature Delay Lines

High temperature delay lines function as a protective buffer between the hot surface of the test piece and the transducer's crystal. At elevated temperatures, intermittent contact is recommended to protect the transducer from thermal damage.

Element 
Diameter

High Temperature Delays

To 350 °F 
(175 °C)
To 500 °F 
(260 °C)
To 900 °F 
(480 °C)
inchesmm
0.513DLHT-201DLHT-2DLHT-2G
0.256DLHT-101DLHT-1DLHT-1G
0.1253DLHT-301DLHT-3DLHT-3G

 

Immersion Transducers

Panametrics-NDT Microscan immersion transducers are designed to transmit and receive ultrasound in water. Thickness measurements by immersion technique are often preferred when the test piece has a complex geometry or in online applications. Typical offline applications include wall thickness measurements on small diameter plastic or metal tubing, scanned or rotary measurements and thickness measurements on sharply curved parts. Transducer focusing may be necessary depending on the application.

FrequencyElement DiameterTransducer Part NumberTransducer Part 
Code
(MHz)inchesmm
2.250.513M306-SUU8410027
50.513M309-SUU8420001
50.256M310-SUU8420004
100.256M312-SUU8420008
150.256M313-SUU8420009
200.1253M316-SUU8420011

Bubblers

We offer bubblers for easy implementation of immersion testing. They act as a holder for the transducers to maintain consistent water flow from transducer to test surface, and prevent the accumulation of air bubbles on the transducer face.

Part NumberOpeningWater PathFits Transducer 
Part Number
inchesmminchesmm
B1000.12531.2532M310A-SM, M312A-SM, M316A-SM
B103*0.3590.57514.5M310-SU, M312-SU, M313-SU, M316-SU
B103W*0.55140.77519.7M306-SU, M309-SU
B103A*0.3590.57514.5same as B103
* The B103 has a V-notch shaped opening; the B103A and B103W are flat.

Bubbler Transducer Assembly

Handheld bubbler transducers are available in either 20 MHz (V316B) or 10 MHz (V312B). They are immersion transducers that screw onto a bubbler assembly (B120), which has a replaceable stainless steel tip and a water feed tube. They offer high resolution and easy access inspection of thin materials.

RBS-1 Immersion Tank

Panametrics-NDT RBS-1 immersion tank is designed to simplify ultrasonic thickness measurements using immersion techniques. It consists of a clear acrylic tank, a submersible pump and a transducer fixture in a single, portable unit. It is ideal for offline thickness measurements on metal, glass and plastic products such as small containers, pipe or tubing, sheets or plates or machined parts.

Tank
• 5.5 x 12 x 8 in (140 x 305 x 200 mm) 
• 0.83 gallon (3.1 liter) capacity

Pump
• 0 to 0.25 gallons (0 to 0.9 liters) per minute 
• 115 or 230 V, 30 Watt (voltage range 90 to 135 VAC), 50 to 60 Hz 
• Submersible (ground fault interrupter circuit recommended)

Couplants

The use of couplant is almost always necessary to provide acoustic coupling between the transducer and the test piece. We offer various types of couplants to suit virtually all applications.

Part NumberDescriptionVolumeApplication
A2 
AP 
AQ 
AG
Propylene Glycol 
Propylene Glycol 
Propylene Glycol 
Propylene Glycol
2 oz (0.06 liter) 
1 pint (0.47 liter) 
1 quart (0.95 liter) 
1 gallon (3.78 liter)
General purpose couplant for smooth surfaces. Chemically non-reactive; does not evaporate quickly. The maximum recommended temperature is 200 °F (90 °C)
B2 
BQ
Glycerin 
Glycerin
2 oz. (0.06 liter) 
1 qt. (0.95 liter)
General purpose, more viscous and has a high acoustic impedance making it the preferred couplant for rough surfaces and highly attenuating materials.
D12 
DG 
D-5G
Gel Type 
Gel Type 
Gel Type
12 oz. (0.35 liter) 
1 gal. (3.78 liter) 
5 gal. (18.90 liter)
Rough surfaces such as sand-cast metals and fiberglass layups, weld inspections, overhead surfaces or vertical walls.
E-2Ultratherm2 oz. (0.06 liter)500 °F to 970 °F (260 °C to 520 °C)
G-2Medium Temp2 oz. (0.06 liter)0 °F to 600 °F (-12 °C to 315 °C) Easy removal at high temperatures. Non-toxic and biodegradable
SWCShear Wave4 oz. (0.12 liter)Normal Incidence Shear Wave, non-toxic, water soluble organic substance of very high viscosity.

Calibration Test Blocks

Test blocks are necessary for the calibration of ultrasonic thickness gages and should be used to maintain and verify the accuracy, dependability and reliability of ultrasonic measurements. Blocks are held to tighter tolerances than called out in ASTM E797 code. Metric test blocks are available.

Part NumberMaterialSteps
2211E304 Stainless Steel.100, .200, .300, .400 and .500 in
2212E1018 Carbon Steel.250, .500, .750, .400 and 1.00 in
2213E7075-T6 Aluminum.100, .200, .300, .400 and .500 in
2214E1018 Carbon Steel.100, .200, .300, .400 and .500 in
2214M1018 Carbon Steel2.5, 5.0, 7.5, 10.0 and 12.5 mm

 

?Transducer Cables
Olympus-NDT offers a wide selection of transducer cables suitable for all ultrasonic thickness gaging instrumentation.

 

Part NumberConnectorsAvailable Lengths
LCM-74-XSmall LEMO® 00 to Microdot®3 ft (0.9 m), 4 ft (1.2 m), 
6 ft (1.8 m)
LCB-74-XSmall LEMO® 00 to BNC3 ft (0.9 m), 4 ft (1.2 m), 
6 ft (1.8 m)
BCM-74-XBNC to Microdot®3 ft (0.9 m), 4 ft (1.2 m), 
6 ft (1.8 m)
LCU-74-XLEMO® 00 to UHF3 ft (0.9 m)

 

Standard

• Standard cables are recommended for normal usage.

Heavy Duty - Teflon®

• Heavy duty, Teflon® (HD) transducer cables may provide durability and longer life.

Waterproof

• Waterproof (W) cables are recommended in many tests with immersion transducers. These cables provide a waterproof connection good to about 30 ft (10 m) of fresh water. At greater depths, special cables are available.

Heavy Duty - Armored PVC Jacket


• Heavy duty, armored PVC jacket (HDAP) transducer cables have a spiral stainless steel jacket with a solid PVC coating. Maximum length is 20 ft (7 m).

Heavy Duty - Armored Silicone Jacket

• Heavy duty, armored super flexible silicone jacket (HDAS) transducer cables combine a spiral stainless steel jacket with a heavy silicone coating for great flexibility. Length can be specified up to 20 ft (7 m).

Heavy Duty - Stainless Steel

• Heavy duty, armored stainless steel jacket (SSA) transducer cables are recommended for heavy and industrial use provide flexibility, protection and long life.