產(chǎn)品簡介
爆炸氣體檢測儀可檢測和分析各種類型的爆炸物蒸汽并且能夠很快很準(zhǔn)確的識別出生化制品。
詳細(xì)介紹
*擁有被美國環(huán)保署和白宮國家毒品控制策略批準(zhǔn)的電子鼻技術(shù)的產(chǎn)品。這種技術(shù)也被使用在美國航空航天總署探索其他星球和美國反恐特種*上。
Specifications
Size - Weight:
Sampler
樣品 31.8cm L x 10.9cm W x 17.3cm H – 2.6 kg
Chassis
底盤 31.8cm L x 26.4cm W x 14.5cm H – 8.5 kg
Charger
充電器 34.25 cm L x 14 cm W x 9.5 cm H – 3.5 kg
Power Input (Charger):
輸入功率 100-127 VAC at 3 amps – 50/60 Hz
200-240 VAC at 1.5 amps – 50/60 Hz
Fuse:
保險絲 4 amp, 250 VAC
Battery Pack
電池組 28 VDC, 16 Ahr – Li-Ion ( 6 hr use typical)
Environmental Conditions:
環(huán)境條件 This equipment is designed to be safe at least under the following conditions:該設(shè)備應(yīng)被使用在以下環(huán)境中
Indoor use室內(nèi)
Altitude up to 2,000 m 海拔2000米以上
Temperature of 41o F to 105o F (5o C to 40o C)溫度
Relative humidity of 0 – 95% (non-condensing) 相對濕度
Voltage fluctuations not to exceed ± 10% of the nominal voltage 電源電壓10%內(nèi)的誤差
Transient over voltages according to installation categories II, Pollution degree 2
Detector:
Surface Acoustic Wave quartz microbalance
Dynamic Range 2x104
Temperature: 0oC to 150oC, programmable
System Controller: In Pentium 100 MHz or equivalent processor
Minimum 16MB RAM – 1GB Hard Drive
Windows 95, 98, ME, NT 4.0
Communications: RS-232 between controller4300
Built-in wireless LAN
OPTIONAL: Long Range secure wireless link
Rs232串口通信 內(nèi)置無線局域網(wǎng)
可選設(shè)備:遠(yuǎn)程安全無線鏈路
Sampling: 20-40 ccm sampling flow from internal pump
內(nèi)置泵提供20-40 ccm 取樣率
Time programmable from 1-999 seconds
時間設(shè)定 1-999秒
Sample Introduction: Internal Tenax trap or heated sample loop
內(nèi)部Tenax trap 加熱取樣流程
Inlet Connection: Stainless Steel LUER inlet port
入口連接 不銹鋼LUER入口
Inlet temperature: 50oC to 200oC
入口溫度 50-200
Carrier Gas: Helium (Replaceable Cylinder), 95 cc at 17.6 MPa (2560 psi) - > 200 Samples/cylinder
負(fù)載氣體 氦氣
Column Limits: 35oC to 200oC - depending on column
Column Ramping: Isothermal or ramped from 1-18oC/second
Compound Identification: Automatic with user calibration
混合物檢測 自動 或 用戶選擇刻度
Analysis Time: 1 – 60 seconds
分析時間 1-60秒
Recycle Time: 30 seconds minimum
循環(huán)時間 zui少30秒
Precision: 5% RSD
精確度
Accuracy: 10%
準(zhǔn)確率
Sensitivity: Low ppb level for most compounds
靈敏度
大多數(shù)混合物使用 低ppb值