化工儀器網(wǎng)>產(chǎn)品展廳>工業(yè)在線(xiàn)及過(guò)程控制儀>其它工業(yè)過(guò)程控制及在線(xiàn)分析儀>變送器>MINI MCR-2-UI-I-OLP-PT MINI MCR-2-RPSS-I-2I-PT信號(hào)變送器
MINI MCR-2-UI-I-OLP-PT MINI MCR-2-RPSS-I-2I-PT信號(hào)變送器
- 公司名稱(chēng) 福州恒源泰電器有限公司
- 品牌 Phoenix Contact/菲尼克斯
- 型號(hào) MINI MCR-2-UI-I-OLP-PT
- 產(chǎn)地 德國(guó)
- 廠商性質(zhì) 代理商
- 更新時(shí)間 2023/11/6 14:33:47
- 訪問(wèn)次數(shù) 342
MINI MCR-2-UI-I-OLPMINI MCR-2-TC-UIMINI MCR-2-F-UIMINI MCR-2-POT-UIMINI MCR-2-NAM-2RO-PT
聯(lián)系方式:楊建烽18060818761 查看聯(lián)系方式
聯(lián)系我們時(shí)請(qǐng)說(shuō)明是化工儀器網(wǎng)上看到的信息,謝謝!
產(chǎn)地類(lèi)別 | 進(jìn)口 | 價(jià)格區(qū)間 | 面議 |
---|---|---|---|
應(yīng)用領(lǐng)域 | 化工,石油,冶金,電氣,綜合 |
MINI MCR-2-RPSS-I-2I-PT信號(hào)變送器MINI MCR-2-UI-I-OLP-PT
參數(shù)設(shè)定取決于實(shí)際消 耗的功率(通過(guò)三相電流、電壓和相位 角算出),因而可提供比單獨(dú)考慮電流時(shí) 更加精確的計(jì)算值,與電壓波動(dòng)和驅(qū)動(dòng) 負(fù)載無(wú)關(guān)。如果高于或低于設(shè)定的開(kāi)關(guān) 閾值,EMM模塊會(huì)立刻(或在一個(gè)可調(diào)的 “延時(shí)”之后)執(zhí)行馬達(dá)急停操作。此外, 還會(huì)通過(guò)輸出發(fā)送信息。 這種狀態(tài)只能通過(guò)給定的復(fù)位進(jìn)行 解除。 如果消耗的有效功率高于或低于 信息閾值,僅會(huì)送出一個(gè)持續(xù)一段時(shí)間 的反饋信號(hào),用來(lái)跳開(kāi)模塊。 此外,模塊會(huì)生成識(shí)別旋轉(zhuǎn)方向的 信號(hào)。 也可檢測(cè)不對(duì)稱(chēng)和相位故障,并 發(fā)出信號(hào)報(bào)警。 持續(xù)進(jìn)行的高掃描頻率狀態(tài)監(jiān)視和 快速的半導(dǎo)體開(kāi)關(guān)能保護(hù)包括馬達(dá)在內(nèi) 的整個(gè)系統(tǒng)。 無(wú)需任何額外接線(xiàn)——僅通過(guò)一個(gè)模 塊——就可監(jiān)視泵、執(zhí)行器、風(fēng)扇和工具 的相關(guān)功能是否正常,是否有污物(過(guò) 濾器或類(lèi)似設(shè)備),是否出現(xiàn)磨損等。可 調(diào)的“沖擊抑制”時(shí)間用于跳過(guò)監(jiān)視過(guò)程 的開(kāi)關(guān)操作。系統(tǒng)(IFS)由可通過(guò)DIN 導(dǎo)軌連接器進(jìn)行相互連接的設(shè)備組成。 網(wǎng) 關(guān) 最 多 可 連 接 32臺(tái)IFS設(shè) 備 , 是系統(tǒng)的核心, 且管理各站點(diǎn)。系統(tǒng)特性: – 通過(guò)DIN導(dǎo)軌連接器使用Interface系 統(tǒng),實(shí)現(xiàn)數(shù)據(jù)的參數(shù)化、診斷以及相互 交換 – 與規(guī)定的IFS附件兼容 – 通過(guò)DIN導(dǎo)軌連接器為設(shè)備(如, EMM...IFS、ELR...IFS、EMGATEWAY-IFS)提供24 V供電電壓過(guò)濾器污染警告閾值,防止空轉(zhuǎn)、阻 塞和空蝕。 軸承磨損及其他易引發(fā)過(guò)載的警告 閾值,防止阻塞。 工具和軸承磨損警告閾值,防止阻 塞和工具破損。通過(guò)設(shè)置運(yùn)行閾值下限可防止危險(xiǎn) 的空轉(zhuǎn),為泵提供有效保護(hù)。 通過(guò)設(shè)置“延時(shí)時(shí)間”可避免暫時(shí)的 功能故障(如氣泡),這樣便可避免因其 導(dǎo)致驅(qū)動(dòng)意外停止。 馬達(dá)管理器也可用于保護(hù)機(jī)床的馬 達(dá)和重要的系統(tǒng)部件。通過(guò)設(shè)置相應(yīng)的 功率閾值參數(shù)來(lái)實(shí)現(xiàn)。例如:如果進(jìn)料 快,模塊即可檢測(cè)出來(lái),并在刀具被破壞 前制動(dòng)。 另外,通過(guò)信息閾值即可提前收到 刀具磨損的信號(hào)。功率監(jiān)視的所有優(yōu)點(diǎn)。模塊會(huì)根據(jù)三相 電流、電壓和相角,每6.6 ms計(jì)算一次 設(shè)備傳動(dòng)系統(tǒng)或其他三相設(shè)備的有效功 率。若每相電流小于16 A,可選擇內(nèi)置 電流互感器模塊;若電流大于16 A,需 要外接電流互感器。模塊的數(shù)字量輸出 信號(hào)用于控制單獨(dú)的機(jī)械或電子開(kāi)關(guān)元 件,以適應(yīng)實(shí)際負(fù)載開(kāi)關(guān)的需要。EMM 模塊能可靠地保護(hù)所接負(fù)載(與它們的 功耗無(wú)關(guān)),避免過(guò)載和欠載,并且提供 持續(xù)的狀態(tài)監(jiān)視。 最多可自由設(shè)置8個(gè)開(kāi)關(guān)或報(bào)警閾 值,且最多可自由組態(tài)4個(gè)輸入和輸出, 以保護(hù)電氣傳動(dòng)設(shè)備和系統(tǒng)。 EMM可記錄以下數(shù)據(jù): – 視在功率、有功功率和無(wú)功功率 – 電流和電壓 – 相角 – 開(kāi)關(guān)周期和工作小時(shí)數(shù) – 功率表 附加功能: – 雙金屬功能,可在Class 5-40范圍調(diào)節(jié) – 熱敏電阻監(jiān)視器 – 記錄測(cè)量值 – 通過(guò)DIN導(dǎo)軌連接器連接GATEWAY – 預(yù)組態(tài)電動(dòng)進(jìn)料器,如換向啟動(dòng)器、星 形三角啟動(dòng)器等。 例如,EMM模塊可用于記錄完整的“ 驅(qū)動(dòng)曲線(xiàn)”,作為系統(tǒng)文檔。 EMM模塊的運(yùn)行模式有正轉(zhuǎn)、反 轉(zhuǎn)、換向及極限開(kāi)關(guān)運(yùn)行(內(nèi)置重啟抑 制),用于開(kāi)關(guān)執(zhí)行器和驅(qū)動(dòng)裝置、泵和 類(lèi)似裝置等,也可用于磨損檢查。 電流互感器 應(yīng)選擇次級(jí)額定電流為5 A的外接轉(zhuǎn) 換器。初級(jí)電流取決于設(shè)備的電流損耗 (可參考接線(xiàn)圖)。適用于電流互感器, 見(jiàn)產(chǎn)品目錄:電子接口技術(shù)和開(kāi)關(guān)備。。 DIN導(dǎo)軌連接器 DIN導(dǎo)軌連接器(訂貨號(hào)2201937) 可用于多個(gè)EMM模塊的24 V DC供電或 將最多32個(gè)EMM模塊與EM-PROFINETGATEWAY-IFS相連。 開(kāi)關(guān)裝置 根據(jù)實(shí)際負(fù)載開(kāi)關(guān)要求,可采用機(jī) 電式接觸器或換向接觸器組合,或者固 態(tài)接觸器/固態(tài)換向接觸器組合。這些開(kāi) 關(guān)單元通過(guò)EMM的數(shù)字量輸出信號(hào)控 制。無(wú)論是6 mm超薄型變送器、功能安 全型隔離器,還是用于危險(xiǎn)區(qū)域的隔離 變送器,菲尼克斯電氣的變送器和數(shù)顯 表系列產(chǎn)品都能為模擬量信號(hào)調(diào)節(jié)領(lǐng)域 的各類(lèi)應(yīng)用提供解決方案。 變送器優(yōu)勢(shì) – 超薄型隔離變送器,與市場(chǎng)上的同類(lèi) 隔離器產(chǎn)品相比,最多可節(jié)省65%的 空間 – 支持總線(xiàn)和網(wǎng)絡(luò)連接,可將現(xiàn)場(chǎng)信號(hào) 集成到工業(yè)網(wǎng)絡(luò),同時(shí)確保安全的電 氣隔離 – 通過(guò)SIL認(rèn)證,傳輸精確,操作安全性 高 – 采用防爆區(qū)域本安電路用單通道和雙 通道變送器,為所有防爆區(qū)域和氣體 提供較好的防爆保護(hù) – 性能強(qiáng)大,可按機(jī)械指令的要求,輕松 將模擬量信號(hào)集成到安全應(yīng)用中 數(shù)顯表和現(xiàn)場(chǎng)設(shè)備優(yōu)勢(shì) – 多功能數(shù)顯表可顯示、監(jiān)測(cè)和控制模 擬量和溫度信號(hào) – 采用多功能變送器和2線(xiàn)制現(xiàn)場(chǎng)設(shè)備, 實(shí)現(xiàn)模擬量信號(hào)的無(wú)干擾傳輸和現(xiàn)場(chǎng) 溫度測(cè)量
術(shù)語(yǔ)表/關(guān)于變送器的重要術(shù)語(yǔ) 輸入 輸入信號(hào)最大值: 描述模塊損壞前能夠承受的最大數(shù)值 輸入阻抗: 為電流輸入使用低阻抗和為電壓輸入 使用高阻抗時(shí),產(chǎn)生微小輸入信號(hào)負(fù) 載。 共模抑制比: 描述兩個(gè)輸入相同信號(hào)抑制特征。 模擬量輸出 輸入信號(hào)最大值: 在這個(gè)前提下,無(wú)論輸入端情況如 何,在輸出端上也不會(huì)出現(xiàn)更大的數(shù) 值。 調(diào)節(jié)零點(diǎn)/量程: 零點(diǎn)調(diào)節(jié) = 設(shè)置零點(diǎn) 跨度調(diào)節(jié) = 調(diào)節(jié)相對(duì)于輸入的模擬量 輸出,增加/減小輸出特性曲線(xiàn)的放大系 數(shù)。 負(fù)載: 輸出負(fù)載能力,可“驅(qū)動(dòng)”的總阻抗。 殘波/紋波: 由于電路方面的原因,在信號(hào)處理過(guò) 程中會(huì)在輸出范圍上產(chǎn)生一個(gè)疊加波。 斷路識(shí)別特性: 如果數(shù)值超過(guò)或低于容差限值,將發(fā) 送預(yù)先設(shè)定的輸出。 數(shù)字量輸出 對(duì)于變送器,數(shù)字量輸出可使用繼電 器或晶體管輸出實(shí)現(xiàn)。數(shù)字量輸出的開(kāi) 關(guān)行為可組態(tài)。 有源隔離: 對(duì)于有源隔離,模塊有自己的電源。 有源隔離分為3種情況: – 3端隔離 – 輸入隔離 – 饋電隔離 無(wú)源隔離: 模塊從有源輸入或輸出回路獲得信號(hào) 傳輸和電氣隔離所需電力。因此可分為 – 通過(guò)輸入回路供電 – 通過(guò)輸出回路供電 熱電阻傳感器 熱電阻傳感器(如Pt 100、Ni1000 等)電阻值隨溫度而變化。需要穩(wěn)定的 測(cè)量電流。變送器可檢測(cè)此數(shù)值并將其 轉(zhuǎn)換成相應(yīng)的模擬量信號(hào)。可按連接技 術(shù)分為: – 2線(xiàn)制 – 3線(xiàn)制 – 4線(xiàn)制 熱電偶 不同于熱電阻傳感器,熱電偶有源。 采用不同的金屬,根據(jù)環(huán)境溫度通過(guò)塞 貝克效應(yīng)生成相應(yīng)的電壓。 請(qǐng)參見(jiàn)用戶(hù)手冊(cè)了解關(guān)于MCR技術(shù)的 詳細(xì)信息。其中包括技術(shù)和物理基礎(chǔ)、 應(yīng)用實(shí)例和電路說(shuō)明。此外,用戶(hù)手冊(cè) 還提供關(guān)于功能安全、數(shù)字現(xiàn)場(chǎng)總線(xiàn)系 統(tǒng)相關(guān)信息以及MCR技術(shù)電涌保護(hù)簡(jiǎn) 介。根據(jù)不同的應(yīng)用需求,電氣設(shè)備應(yīng)用 于不同的Ex區(qū)域域系統(tǒng)。變送器和測(cè)量 變送器通常部署于安全范圍內(nèi)(非爆炸 區(qū)域)。采用適用于2區(qū)的IP54防護(hù)外 殼,還可在2區(qū)Ex區(qū)域安裝變送器和測(cè) 量變送器。如果采用Ex d防護(hù)型號(hào)密封 外殼,還可用于潛在爆炸1區(qū)。務(wù)必考 慮相應(yīng)防護(hù)型號(hào)和Ex區(qū)域的要求。 該圖顯示可安裝在具有氣體爆炸危險(xiǎn) 的區(qū)域中的電氣設(shè)備選項(xiàng)。 示例:帶“n”類(lèi)防護(hù)傳感器/執(zhí)行器可 連 接 到 2 區(qū) 中 MINI Analog Pro或 MACX Analog系列隔離器。更為簡(jiǎn)便,精巧依舊 MINI Analog Pro可在有限空間內(nèi)實(shí)現(xiàn) 簡(jiǎn)便的安裝和調(diào)試。 – 最大節(jié)省65%的安裝空間 從下列類(lèi)別中選擇 – 模擬量輸入/輸出 – 溫度 – 頻率 – 電位計(jì) – 數(shù)字量輸入 – 限定值 – 附件 易于安裝 – 接線(xiàn)方便清晰和采用FASTCON Pro技 術(shù)的插拔式接線(xiàn)端子 電源橋接和故障監(jiān)控 – DIN導(dǎo)軌連接器簡(jiǎn)化饋電,通過(guò)群組故 障監(jiān)控實(shí)現(xiàn)遠(yuǎn)程診斷工作過(guò)程中可測(cè)量電流信號(hào) 進(jìn)行調(diào)試和維修工作時(shí),通過(guò)內(nèi)置測(cè) 量二極管可方便地測(cè)量信號(hào)。 – 無(wú)需斷開(kāi)電流電路即可將電流測(cè)量設(shè) 備集成到信號(hào)回路中。 – 維修和調(diào)試時(shí),只需將插拔式端子斷 開(kāi)即可輕松斷開(kāi)信號(hào)回路 易于維護(hù) –大面積標(biāo)識(shí)區(qū)域可粘貼標(biāo)準(zhǔn)標(biāo)識(shí)材 料,用于辨別每個(gè)回路且每個(gè)模塊中 的LED狀態(tài)持續(xù)可見(jiàn)連接技術(shù)選擇 – 用戶(hù)可選擇螺釘連接或免工具直插式 連接技術(shù) 滿(mǎn)足各類(lèi)應(yīng)用要求 – 寬電壓輸入和寬溫工作范圍,功能更 多樣優(yōu)質(zhì)信號(hào)質(zhì)量 – 采用全新的傳輸技術(shù),輸入、輸出和 電源之間在3 kV的測(cè)試電壓下可實(shí)現(xiàn) 有效的安全電氣隔離
– 通用可組態(tài)的超薄型變送器,帶開(kāi)關(guān) 輸出,用于標(biāo)準(zhǔn)模擬量信號(hào)的電氣隔 離、轉(zhuǎn)換、放大和濾波 – 端子可插拔,4端安全隔離 – 通過(guò)DIP開(kāi)關(guān),可實(shí)現(xiàn)標(biāo)準(zhǔn)信號(hào)組合組態(tài),通過(guò)軟件或智能手機(jī)應(yīng)用程序自由組態(tài) ,通過(guò)DIN導(dǎo)軌連接器實(shí)現(xiàn)供電和故障 監(jiān)視 – 可組態(tài)輸出端的限制行為 – LED故障和狀態(tài)指示,通過(guò)輸出回路供電的單通道或雙通道2 端隔離饋電隔離器采用插拔式連接技 術(shù),用于模擬量信號(hào)的電氣隔離和濾 波。該設(shè)備可在有源模擬量輸入模塊上運(yùn) 行 – 該模塊和連接的傳感器通過(guò)控制器電 流回路供電,因此無(wú)需額外的電源
MINI MCR-2-UNI-UI-UIRO-PT
MINI MCR-2-UNI-UI-UIRO
MINI MCR-2-UNI-UI-UIRO-PT-C
MINI MCR-2-UNI-UI-UIRO-C
MINI MCR-2-UNI-UI-2UI-PT
MINI MCR-2-UNI-UI-2UI
MINI MCR-2-UNI-UI-2UI-PT-C
MINI MCR-2-UNI-UI-2UI-C
MINI MCR-2-UI-UI-PT
MINI MCR-2-UI-UI
MINI MCR-2-UI-UI-PT-C
MINI MCR-2-UI-UI-C
MINI MCR-2-U-UI-PT
MINI MCR-2-U-UI
MINI MCR-2-U-UI-PT-C
MINI MCR-2-U-UI-C
MINI MCR-2-U-I0-PT
MINI MCR-2-U-I0
MINI MCR-2-U-I4-PT
MINI MCR-2-U-I4
MINI MCR-2-I0-U-PT
MINI MCR-2-I0-U
MINI MCR-2-I4-U-PT
MINI MCR-2-I4-U
MINI MCR-2-I-I-PT
MINI MCR-2-I-I
MINI MCR-2-U-U-PT
MINI MCR-2-U-U
MINI MCR-2-RPSS-I-I-PT
MINI MCR-2-RPSS-I-I
MINI MCR-2-RPSS-I-2I-PT
MINI MCR-2-RPSS-I-2I
MINI MCR-2-RPS-I-I-OLP-PT
MINI MCR-2-RPS-I-I-OLP
MINI MCR-2-RPS-2I-2I-OLP-PT
MINI MCR-2-RPS-2I-2I-OLP
MINI MCR-2-I-I-ILP-PT
MINI MCR-2-I-I-ILP
MINI MCR-2-2I-2I-ILP-PT
MINI MCR-2-2I-2I-ILP
MINI MCR-2-UI-I-OLP-PT
MINI MCR-2-UI-I-OLP
MINI MCR-2-UI-I-OLP-PT-C
MINI MCR-2-UI-I-OLP-C
MINI MCR-2-RTD-UI-PT
MINI MCR-2-RTD-UI
MINI MCR-2-RTD-UI-PT-C
MINI MCR-2-RTD-UI-C
MINI MCR-2-TC-UI-PT
MINI MCR-2-TC-UI
MINI MCR-2-TC-UI-PT-C
MINI MCR-2-TC-UI-C
MINI MCR-2-F-UI-PT
MINI MCR-2-F-UI
MINI MCR-2-F-UI-PT-C
MINI MCR-2-F-UI-C
MINI MCR-2-SPS-24-15-PT
MINI MCR-2-SPS-24-15
MINI MCR-2-UI-FRO-PT
MINI MCR-2-UI-FRO
MINI MCR-2-UI-FRO-PT-C
MINI MCR-2-UI-FRO-C
MINI MCR-2-POT-UI-PT
MINI MCR-2-POT-UI
MINI MCR-2-POT-UI-PT-C
MINI MCR-2-POT-UI-C
MINI MCR-2-NAM-2RO-PT
MINI MCR-2-NAM-2RO
MINI MCR-2-UI-REL-PT
MINI MCR-2-UI-REL
MINI MCR-2-UI-REL-PT-C
MINI MCR-2-UI-REL-C
MINI MCR-2-T-REL-PT
MINI MCR-2-T-REL
MINI MCR-2-T-2RO-PT
MINI MCR-2-T-2RO
實(shí)現(xiàn)從現(xiàn)場(chǎng)到網(wǎng)絡(luò)的安全電氣隔 離。變送器支持總線(xiàn)和 網(wǎng)絡(luò)連接,結(jié)合了安全電氣隔離和數(shù)字 化通信兩個(gè)功能特性。無(wú)需使用與特定 信號(hào)相關(guān)的輸入卡件,即可在50 mm的 寬度范圍內(nèi)將8通道信號(hào)不受干擾地傳 輸至工業(yè)網(wǎng)絡(luò)。 更多優(yōu)點(diǎn): – 用于不同協(xié)議的網(wǎng)關(guān),變送器可實(shí)現(xiàn)安全的電氣隔離,確保 現(xiàn)場(chǎng)層到CPU之間信號(hào)傳輸無(wú)干擾 – 通過(guò)總線(xiàn)傳輸所有型號(hào)的信號(hào),實(shí)現(xiàn) 快速、無(wú)差錯(cuò)布線(xiàn)無(wú)需輸入卡件 – 無(wú)需使用配套的輸入卡件,節(jié)省空間 和成本 模塊化設(shè)計(jì),節(jié)省空間 – 變送器可自由組合,通過(guò)插拔式網(wǎng)關(guān) 可集成到工業(yè)網(wǎng)中,節(jié)省空間 靈活組態(tài) – 通過(guò)撥碼開(kāi)關(guān)、軟件、Web服務(wù)器或應(yīng) 用程序等方式可實(shí)現(xiàn)參數(shù)快速設(shè)置智能組態(tài)和監(jiān)視 – 通過(guò)MINI即可進(jìn)行現(xiàn) 場(chǎng)組態(tài)并且能直接從智能手機(jī)上讀取 電流值 輕松調(diào)試和維修 – 無(wú)需斷開(kāi)電流回路即可測(cè)量電流信號(hào) 便于維護(hù) – 大面積標(biāo)識(shí)區(qū)域可粘貼標(biāo)準(zhǔn)標(biāo)識(shí)材 料,且每個(gè)模塊中的LED狀態(tài)和故障情 況長(zhǎng)久可見(jiàn)
MINI MCR-2-V8-MOD-RTU
MINI MCR-2-V8-PB-DP
MINI MCR-2-V8-MOD-TCP
MINI MCR-2-CVCS-PT
MINI MCR-2-CVCS
MINI MCR-2-SPS-24-15-PT
MINI MCR-2-SPS-24-15
MINI MCR-2-PTB-PT
MINI MCR-2-PTB
MINI MCR-2-TB
MINI MCR-2-FM-RC-PT
MINI MCR-2-FM-RC
系統(tǒng)布線(xiàn)適配器,可插接多達(dá)8個(gè)變送器 因其創(chuàng)新插入式設(shè)計(jì),MINI MCR-2-V8-FLK16系統(tǒng)適配器可提供節(jié)約接線(xiàn) 時(shí)間的解決方案。8個(gè)MINI Analog Pro 信號(hào)轉(zhuǎn)換器可通過(guò)可插拔系統(tǒng)電纜輕松 連接控制器。使用系統(tǒng)布線(xiàn),只需插入 PLC即可連接MINI Analog Pro模塊,與 控制器側(cè)單獨(dú)接線(xiàn)相比,顯著減少接線(xiàn) 工作量并降低接錯(cuò)風(fēng)險(xiǎn)。 FLK 16系統(tǒng)適配器還可為總線(xiàn)和網(wǎng) 絡(luò)連接提供各種網(wǎng)關(guān)功能,比如組態(tài)和 讀取NFC測(cè)量數(shù)值、持續(xù)測(cè)量電流、大面 積標(biāo)識(shí)區(qū)域以及始終可見(jiàn)的診斷和狀態(tài) LED指示。 更多優(yōu)點(diǎn): – 即插即用型MINI變送器解 決方案 – 每個(gè)通道均配備安全電氣隔離,節(jié)省 大量時(shí)間和成本 – 系統(tǒng)布線(xiàn)適配器采用模塊化插拔式設(shè) 計(jì),節(jié)省空間終端板是一套緊湊型解決方 案,通過(guò)系統(tǒng)電纜可輕松將MINI系列的標(biāo)準(zhǔn)DIN導(dǎo)軌變送器連接到自 動(dòng)化系統(tǒng)的輸入和輸出卡件上。終端板 還可用于MACX和緊湊的變送器與緊湊靈活的端接板 組合,實(shí)現(xiàn)控制柜內(nèi)專(zhuān)業(yè)的系統(tǒng)接線(xiàn)和 目前市場(chǎng)上超高的接線(xiàn)密度。 緊湊型 – 與MINI Analog相應(yīng)的緊湊型設(shè)計(jì)可節(jié) 省控制柜內(nèi)65%的空間 堅(jiān)固可靠 – 牢固抗震的鋁質(zhì)外殼支架 – PCB與變送器分離 – PCB,不帶有源電子組件 – 通過(guò)獨(dú)立的DIN導(dǎo)軌模塊進(jìn)行冗余供 電 – 水平或垂直DIN導(dǎo)軌安裝 靈活 – 不帶針距標(biāo)識(shí)的外形 – 通過(guò)可插拔電纜套件實(shí)現(xiàn)快速安全的 模塊連接 – 水平或垂直DIN導(dǎo)軌安裝 – 可靈活適配各種控制器或高級(jí)控制系 統(tǒng) – 根據(jù)您的需求定制解決方案 – 提供預(yù)組裝模塊、已接線(xiàn)、或可自行組 裝的型號(hào)可靠且安全 設(shè)備和系統(tǒng)具備非常高的安全性 菲尼克斯電氣在標(biāo)準(zhǔn)化開(kāi)發(fā)過(guò)程 中,遵循標(biāo)準(zhǔn)對(duì)功能安全性 的要求。從設(shè)備開(kāi)發(fā)和生產(chǎn)直到設(shè)備運(yùn) 行,安全生命周期內(nèi)采取了可以避免和 控制故障的各項(xiàng)措施。 精準(zhǔn)、無(wú)干擾的信號(hào)傳輸和較長(zhǎng)的使用 壽命 – 獲得的傳輸方案,帶安全電氣隔 離 – 低功耗,低自熱 輕松組態(tài)和監(jiān)測(cè) – 通過(guò)FDT或內(nèi)置監(jiān)測(cè)軟件的獨(dú)立 軟件。 – 或者,無(wú)需軟件,通過(guò)設(shè)備正面的DIP 開(kāi)關(guān)操作
智能供電與診斷方案 – 通過(guò)DIN導(dǎo)軌連接器連接24 V電源橋 接,簡(jiǎn)化接線(xiàn)、系統(tǒng)擴(kuò)展或模塊熱插拔 更換。通過(guò)MACX模塊或電源直接供 電,默認(rèn)報(bào)告模塊帶有冗余二極管退 耦電源和默認(rèn)報(bào)告選項(xiàng) – 寬域供電:寬域輸入型號(hào)可直接安裝在 全球各地所有電源網(wǎng)絡(luò)中,無(wú)需附加 電源設(shè)備 信號(hào)連接迅速、無(wú)誤 – 緊湊型終端板通過(guò)預(yù)裝系統(tǒng)布線(xiàn),可輕松快速地將MACX DIN 導(dǎo)軌設(shè)備連接到自動(dòng)化系統(tǒng)的輸入和 輸出卡件上,實(shí)現(xiàn)即插即用 – 與市場(chǎng)上其他解決方案相比,可節(jié)省 高達(dá)30%的空間 – 堅(jiān)固鋁質(zhì)外殼搭配機(jī)械退耦PCB,提 高系統(tǒng)可用性 – DIN導(dǎo)軌和系統(tǒng)應(yīng)用采用同一種工程 設(shè)計(jì)方法,維護(hù)簡(jiǎn)單 便于維護(hù)的連接技術(shù) – 插拔式連接技術(shù),支持螺釘連接或直 插式彈簧連接 – 編碼和清晰的標(biāo)記有效避免極性逆 轉(zhuǎn),防止預(yù)制接線(xiàn)端子意外錯(cuò)配 – 例如,用于測(cè)試或連接HART通信的集 成插座本安信號(hào)在潛在爆炸危險(xiǎn)區(qū)域的傳輸 許多過(guò)程技術(shù)系統(tǒng)都存在易爆區(qū)。因 此,測(cè)量和控制電路通常按本安電路等級(jí)標(biāo)準(zhǔn)進(jìn)行設(shè)計(jì)。 本安保護(hù)與其他型號(hào)的保護(hù)(如增安 型或Ex e)不同,不僅保護(hù)單獨(dú)的設(shè)備, 還保護(hù)整個(gè)電路。如果電流和電壓被限 制在沒(méi)有火花或熱效應(yīng)可引起爆炸性氣 體被點(diǎn)燃的范圍內(nèi),則該電路為本安型。 本安電路通常包括至少一個(gè)本安設(shè)備 (現(xiàn)場(chǎng)設(shè)備)和一個(gè)相關(guān)設(shè)備(Ex i變送 器)以及連接電纜。本安設(shè)備和相關(guān)設(shè) 備的安全部件按IEC/EN 60079-11標(biāo)準(zhǔn) 分 為 ia、ib和 ic安 全 等 級(jí) 。 用 戶(hù) 按所述要求所采納本安 的演示用于確保上述互聯(lián)實(shí)現(xiàn)本安。 這種保護(hù)為用戶(hù)提供下列優(yōu)勢(shì): – 無(wú)需特別許可即可在系統(tǒng)運(yùn)行期間開(kāi) 展維修和轉(zhuǎn)換工作 – 未采用成本高昂的外殼設(shè)計(jì),經(jīng)濟(jì)實(shí) 用 – 任意制造商生產(chǎn)的Ex i現(xiàn)場(chǎng)設(shè)備和Ex i 變送器均可組合使用。功能安全(SIL) 術(shù)語(yǔ)SIL(安全完整性等級(jí))是過(guò)程技 術(shù)領(lǐng)域的重要術(shù)語(yǔ)。它定義了設(shè)備或系 統(tǒng)必須滿(mǎn)足的要求,從而描述了故障發(fā) 生的概率。如果設(shè)備或系統(tǒng)發(fā)生故障, 將進(jìn)入既定安全狀態(tài)。 基本標(biāo)準(zhǔn) “電氣/電子/可編 程電子安全相關(guān)系統(tǒng)的功能性安全”描述 生產(chǎn)廠商必須在其設(shè)備或系統(tǒng)中考慮的 要求。 標(biāo)準(zhǔn)IEC 61511“功能安全性——用于過(guò) 程工業(yè)領(lǐng)域中的安全儀表系統(tǒng)”描述構(gòu)建 功能安全系統(tǒng)的要求。操作員、擁有人 和規(guī)劃師負(fù)責(zé)按國(guó)家規(guī)定遵守此標(biāo)準(zhǔn)。描述平均故障概率和安全儀表功能等級(jí)之間的關(guān)聯(lián)以及風(fēng)險(xiǎn)降 低。 SIL 安全完整性等級(jí) PFDavg 低要求模式 (要求的功能平均故障概率) PFH 高要求模式 (每小時(shí)發(fā)生危險(xiǎn)故障的概率) RRF 風(fēng)險(xiǎn)降低因數(shù) (風(fēng)險(xiǎn)降低因數(shù)標(biāo) 準(zhǔn) 規(guī) 定 性 能 等 級(jí) (PL)術(shù)語(yǔ),是指機(jī)械安全性。附表給 出要求的性能等級(jí)(PL)和每小時(shí)發(fā)生 危險(xiǎn)故障的平均概率(PFHd)之間的 關(guān)聯(lián)。
MACX MCR-UI-UI
MACX MCR-UI-UI-SP
MACX MCR-UI-UI-NC
MACX MCR-UI-UI-SP-NC
MACX MCR-UI-UI-UP
MACX MCR-UI-UI-UP-SP
MACX MCR-UI-UI-UP-NC
MACX MCR-UI-UI-UP-SP-NC
MACX MCR-SL-RPSSI-I
MACX MCR-SL-RPSSI-I-SP
MACX MCR-SL-RPSSI-2I
MACX MCR-SL-RPSSI-2I-SP
MACX MCR-SL-RPSSI-I-UP
MACX MCR-SL-RPSSI-I-UP-SP
MACX MCR-SL-RPSS-2I-2I
MACX MCR-SL-RPSS-2I-2I-SP
MACX MCR-SL-I-I-ILP
MACX MCR-SL-I-I-ILP-SP
MACX MCR-SL-2I-2I-ILP
MACX MCR-SL-2I-2I-ILP-SP
MACX MCR-SL-I-I-HV-ILP
MACX MCR-SL-I-I-HV-ILP-SP
MACX MCR-SL-2I-2I-HV-ILP
MACX MCR-SL-2I-2I-HV-ILP-SP
MACX MCR-T-UIREL-UP
MACX MCR-T-UIREL-UP-SP
MACX MCR-T-UIREL-UP-C
MACX MCR-T-UIREL-UP-SP-C
MACX MCR-T-UI-UP
MACX MCR-T-UI-UP-SP
MACX MCR-T-UI-UP-C
MACX MCR-T-UI-UP-SP-C
MACX MCR-RTD-I
MACX MCR-RTD-I-SP
MACX MCR-RTD-I-C
MACX MCR-RTD-I-SP-C
MACX MCR-TC-I
MACX MCR-TC-I-C
MACX MCR-SL-NAM-R
MACX MCR-SL-NAM-R-SP
MACX MCR-SL-NAM-2RO
MACX MCR-SL-NAM-2RO-SP
MACX MCR-SL-2NAM-RO
MACX MCR-SL-2NAM-RO-SP
MACX MCR-SL-2NAM-R-UP
MACX MCR-SL-2NAM-R-UP-SP
MACX MCR-SL-NAM-2T
MACX MCR-SL-NAM-2T-SP
MACX MCR-SL-2NAM-T
MACX MCR-SL-2NAM-T-SP
MACX MCR-SL-UI-REL
MACX MCR-SL-UI-REL-SP
MACX MCR-EX-SL-RPSSI-I
MACX MCR-EX-SL-RPSSI-I-SP
MACX MCR-EX-SL-RPSSI-2I
MACX MCR-EX-SL-RPSSI-2I-SP
MACX MCR-EX-SL-RPSSI-2I-1S
MACX MCR-EX-SL-RPSSI-2I-1S-SP
MACX MCR-EX-SL-RPSS-2I-2I
MACX MCR-EX-SL-RPSS-2I-2I-SP
MACX MCR-EX-SL-RPSSI-I-UP
MACX MCR-EX-SL-RPSSI-I-UP-SP
MACX MCR-EX-RTD-I
MACX MCR-EX-RTD-I-SP
MINI MCR-2-RPSS-I-2I-PT信號(hào)變送器MINI MCR-2-UI-I-OLP-PT
相關(guān)分類(lèi)
該廠商的其他產(chǎn)品
- MACX MCR-SL-2NAM-T-SP 信號(hào)變送器MINI MCR-2-F-UI-PT-C菲尼克斯
- MINI MCR-2-TC-UI-PT-C MINI MCR-2-UI-I-OLP-PT-C信號(hào)變送器
- MACX MCR-SL-RPSSI-I 菲尼克斯信號(hào)變送器MINI MCR-2-POT-UI-C
- MACX MCR-EX-RTD-I-C 信號(hào)變送器MACX MCR-EX-SL-RPSS-2I-2I
- MACX MCR-EX-SL-RPSSI-I 信號(hào)變送器MACX MCR-SL-RPSS-2I-2I-SP
- MINI MCR-2-UI-I-OLP-PT-C 信號(hào)變送器MINI MCR-2-RPS-2I-2I-OLP-PT
- MINI MCR-2-RTD-UI-PT-C MINI MCR-2-RPSS-I-2I菲尼克斯信號(hào)變送器
- MINI MCR-2-RPS-I-I-OLP-PT 信號(hào)變送器MINI MCR-2-UNI-UI-2UI-C