雷電浪涌模擬器LSS-15AX Series FEATURES
雷電浪涌模擬器LSS-15AX Series Fully compliant with the requirements called for in the 2nd edition of IEC 61000-4-5 standard, the LSS-15AX series simulators provide a testing facility for up to 15kV test voltage without sacrificing safety and ease of use. The LSS-15AX simulators generate the two combination pulses 1.2/50 µs (8/20 µS) and 10/700 µS (5/320 µS).
- Fully programmable and easy to use simulator that meets and far exceeds the IEC 61000-4-5 (2nd edition) requirements
- 15kV testing
- Advanced safety
- Flexible test sequencing with Program Mode
:
公司名稱:深圳市華睿高電子技術有限公司/肖
: :
LSS-15AX Series FUNCTIONS
- Fully programmable and easy to use simulator that meets and far exceeds the IEC 61000-4-5 (2nd edition) requirements
- 15kV testing
- Advanced safety
- Flexible test sequencing with Program Mode
:
公司名稱:深圳市華睿高電子技術有限公司/肖
: :
LSS-15AX Series FUNCTIONS
| Very intuitive settings can be done by the assistance of the well configured user-interface consisting of a 5-inch LCD, ten-key, functions keys and others. Coupling modes are graphically shown, allowing the operator to select the desired mode and allows easy reference of settings when the test is in progress. |
| This button, easily accessible and placed on the front panel, enables the operator to stop the generation of the pulses anytime he/she desires. In addition to the high voltage power, the operator can turn off the EUT. |
| A safely interlock is provided through the special design high voltage connector. The high voltage circuitry never be activated when the connector is not correctly positioned or not firmly locked. |
| The value of the actual peak amplitude is measured and shown for both voltage and current. |
| LSS-15AX-C3A stops generating the pulses if the peak current measured exceeds the threshold limit which can be freely set as the breakdown criteria. |
LSS-15AX Series SPECIFICATIONS |
|
LSS-15AX Series DISPLAY EXAMPLES |
LSS-15AX-C3A menus can be selected in the menu display.
| ||
MANUAL MODE TEST SETTING DISPLAY (1) When manual mode test is selected in the menu display, the corresponding test setting display will be shown. The output voltage, waveform and other test parameters can be set. Unnecessary items are indicated lightly and the simulator does not accept change in setting. | ||
MANUAL MODE TEST SETTING DISPLAY (2) Some items can be selected on pop up menus. The right example shows the choices on "Output To". | ||
AC/DC INJECTION SETTING DISPLAY Press the coupling mode key. Coupling mode selection screen will appear. The example shows the 3-phase AC CDN screen on which coupling and return lines can be set. On the ecom CDN setting screen the number of lines (2 or 4 lines), limit resistance (25 ohm or 40 ohm) and return line (1, 2, 3, 4 or PE) can be set. |
LSS-15AX Series TEST SET UP EXAMPLE LSS-15AX-C3A Capacitive coupling on single-phase AC lines in Line-to-line & line-to-ground mode |
INCLUDED ACCESSORIES |
LSS-15AX Series The following accessories are included.
- AC line input cable (4-core: 2m): 1pc
- DC line input cable (3-core: 2m): 1pc
- Surge output cable for surge output (2m) : 2 pcs
- Surge output cable for injection line (2m) : 5 pcs
- Monitoring coaxial cable (1m): 2 pcs
- PE cable (for main unit: 2m): 1pc
- PE cable (for injection line: 2m): 1pc
- Interlock connector: 1pc
- Instruction manual: 1 pc (English)
- Connector caps (7pcs) are fitted to the main unit when it leaves our factory.